Clopidogrel in Combination With Aspirin Improves Vein Graft Patency Following CAGS

2018 ◽  
Vol 27 ◽  
pp. S513
Author(s):  
Daniel Florisson ◽  
Joshua De Bono ◽  
Sean Conte ◽  
Reece Davies ◽  
Andrew Newcomb
Keyword(s):  
1994 ◽  
Vol 72 (05) ◽  
pp. 676-681 ◽  
Author(s):  
J van der Meer ◽  
H L Hillege ◽  
P H J M Dunselman ◽  
B J M Mulder ◽  
H R Michels ◽  
...  

SummaryTo assess the optimal level of oral anticoagulation to prevent occlusion of vein coronary bypass grafts, 318 patients from a graft patency trial were analysed retrospectively. Oral anticoagulant therapy was started one day before surgery and continued for one year, after which graft occlusion was assessed by angiography. The aimed level of anticoagulation was 2.8-1.8 International Normalized Ratio (INR). Clinical outcome was assessed by the incidence of myocardial infarction, thrombosis and major bleeding.The observed anticoagulation level was 2.8-4.8 INR for 54%, and 1.8-3.8 INR for 75% of time per patient. Occlusion rates in patients who spent <35, 35-70, and ≥70% of time within INR range 2.8-1.8 were 10.5%, 10.8% and 11.8%, respectively (differences not statistically significant). Patients who spent ≥70% of time within INR range 1.8-3.8 versus 2.8-4.8 showed comparable occlusion rates. The risk of graft occlusion was not related to quality of anticoagulation early (0-3 months) or late (3-12 months) after surgery. Myocardial infarction, thrombosis and major bleeding occurred in 1.3%, 2.0% and 2.9% of patients.To maintain vein graft patency in the first postoperative year by oral anticoagulation, a level within INR range 1.8-3.8 for ≥70% of time seems to be sufficient.


2018 ◽  
Vol 35 (04) ◽  
pp. 299-305
Author(s):  
Amro Harb ◽  
Maxwell Levi ◽  
Akio Kozato ◽  
Yelena Akelina ◽  
Robert Strauch

Background Torsion of vein grafts is a commonly cited reason for graft failure in clinical setting. Many microsurgery training courses have incorporated vein graft procedures in their curricula, and vein graft torsion is a common technical error made by the surgeons in these courses. To improve our understanding of the clinical reproducibility of practicing vein graft procedures in microsurgery training courses, this study aims to determine if torsion can lead to early vein graft failure in nonsurvival surgery rat models. Methods Sprague-Dawley rats were divided into five cohorts with five rats per cohort for a total of 25 rats. Cohorts were labeled based on degree of vein graft torsion (0, 45, 90, 135, and 180 degrees). Torsion was created in the vein grafts at the distal arterial end by mismatching sutures placed between the proximal end of the vein graft and the distal arterial end. Vein graft patency was then verified 2 and 24 hours postoperation. Results All vein grafts were patent 2 and 24 hours postoperation. At 2 hours, the average blood flow rate measurements for 0, 45, 90, 135, and 180 degrees of torsion were 0.37 ± 0.02, 0.38 ± 0.04, 0.34 ± 0.01, 0.33 ± 0.01, and 0.29 ± 0.02 mL/min, respectively. At 24 hours, they were 0.94 ± 0.07, 1.03 ± 0.15, 1.26 ± 0.22, 1.41 ± 0.11, and 0.89 ± 0.15 mL/min, respectively. Conclusion Torsion of up to 180 degrees does not affect early vein graft patency in rat models. To improve the clinical reproducibility of practicing vein graft procedures in rat models, we suggest that microsurgery instructors assess vein graft torsion prior to clamp release, as vessel torsion does not seem to affect graft patency once the clamps are removed.


Author(s):  
Minh Quan Vu ◽  
Pierre-Emmanuel Noly ◽  
Walid Ben Ali ◽  
Louis P. Perrault

Even though total arterial revascularization is increasingly used, saphenous vein grafts are still the most commonly used conduits for coronary arterial bypass grafting worldwide. Every surgeon should keep in mind that a vascular graft is living tissue with active metabolism, analogous to a solid organ for transplant, and should understand the impact of the choice of the storage solution. Unfortunately, the choice of the storage solution is usually not the result of a thoughtful review of alternatives and evidence but is a function of habit, convenience, and availability. The ideal storage solution should preserve and restore endothelial functional after harvesting. Much effort has been invested in finding ways to avoid or prevent endothelial lesions during harvesting and storage, as well as delaying vein graft dilatation after coronary arterial bypass grafting. After a brief reminder of the vein graft failure pathophysiology, this chapter discusses storage conditions using the existing graft storage solutions and their influence on endothelial function and graft patency. The use of external stenting for vein grafts is addressed elsewhere.


2015 ◽  
Vol 26 (4) ◽  
pp. 328-332 ◽  
Author(s):  
Fatih Sen ◽  
Samet Yilmaz ◽  
Kevser G. Balci ◽  
Ömer Sen ◽  
Murat Gül ◽  
...  

2017 ◽  
Vol 174 (20) ◽  
pp. 3561-3572 ◽  
Author(s):  
M S Fernández-Alfonso ◽  
M Gil-Ortega ◽  
I Aranguez ◽  
D Souza ◽  
M Dreifaldt ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document