Single Parasternal-Long-Axis-View-Sweep Screening Echocardiographic Protocol to Detect Rheumatic Heart Disease: A Prospective Study of Diagnostic Accuracy

2020 ◽  
Vol 29 (6) ◽  
pp. 859-866 ◽  
Author(s):  
Boglarka Remenyi ◽  
Kimberly Davis ◽  
Anthony Draper ◽  
Noel Bayley ◽  
Elizabeth Paratz ◽  
...  
2005 ◽  
Vol 107 (1) ◽  
pp. 001-010 ◽  
Author(s):  
Feridun Kosar ◽  
Ibrahim Sahin ◽  
Nusret Acıkgöz ◽  
Yuksek Aksoy ◽  
Zehra Kucukbay ◽  
...  

Author(s):  
Joshua R. Francis ◽  
Gillian A. Whalley ◽  
Alex Kaethner ◽  
Helen Fairhurst ◽  
Hilary Hardefeldt ◽  
...  

Background: Echocardiographic screening can detect asymptomatic cases of rheumatic heart disease (RHD), facilitating access to treatment. Barriers to implementation of echocardiographic screening include the requirement for expensive equipment and expert practitioners. We aimed to evaluate the diagnostic accuracy of an abbreviated echocardiographic screening protocol (single parasternal-long-axis view with a sweep of the heart) performed by briefly trained, nonexpert practitioners using handheld ultrasound devices. Methods: Participants aged 5 to 20 years in Timor-Leste and the Northern Territory of Australia had 2 echocardiograms: one performed by an expert echocardiographer using a GE Vivid I or Vivid Q portable ultrasound device (reference test), and one performed by a nonexpert practitioner using a GE Vscan handheld ultrasound device (index test). The accuracy of the index test, compared with the reference test, for identifying cases with definite or borderline RHD was determined. Results: There were 3111 enrolled participants; 2573 had both an index test and reference test. Median age was 12 years (interquartile range, 10–15); 58.2% were female. Proportion with definite or borderline RHD was 5.52% (95% CI, 4.70–6.47); proportion with definite RHD was 3.23% (95% CI, 2.61–3.98). Compared with the reference test, sensitivity of the index test for definite or borderline RHD was 70.4% (95% CI, 62.2–77.8), specificity was 78.1% (95% CI, 76.4–79.8). Conclusions: Nonexpert practitioners can be trained to perform single parasternal-long-axis view with a sweep of the heart echocardiography. However, the specificity and sensitivity are inadequate for echocardiographic screening. Improved training for nonexpert practitioners should be investigated.


BMJ Open ◽  
2020 ◽  
Vol 10 (10) ◽  
pp. e038449
Author(s):  
Lisa Helen Telford ◽  
Leila Hussein Abdullahi ◽  
Eleanor Atieno Ochodo ◽  
Liesl Joanna Zuhlke ◽  
Mark Emmanuel Engel

ObjectiveTo summarise the accuracy of handheld echocardiography (HAND) which, if shown to be sufficiently similar to that of standard echocardiography (STAND), could usher in a new age of rheumatic heart disease (RHD) screening in endemic areas.DesignSystematic review and meta-analysis.Data sourcesPubMed, Scopus, EBSCOHost and ISI Web of Science were initially searched on 27 September 2017 and again on 3 March 2020 for studies published from 2012 onwards.Eligibility criteriaStudies assessing the accuracy of HAND compared with STAND when performed by an experienced cardiologist in conjunction with the 2012 World Heart Federation criteria among populations of children and adolescents living in endemic areas were included.Data extraction and synthesisTwo reviewers independently extracted data and assessed the methodological quality of included studies against review-specific Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 criteria. A meta-analysis using the hierarchical summary receiver operating characteristic model was conducted to produce summary results of sensitivity and specificity. Forest plots and scatter plots in receiver operating characteristic space in combination with subgroup analyses were used to investigate heterogeneity. Publication bias was not investigated.ResultsSix studies (N=4208) were included in the analysis. For any RHD detection, the pooled results from six studies were as follows: sensitivity: 81.56% (95% CI 76.52% to 86.61%) and specificity: 89.75% (84.48% to 95.01%). Meta-analytical results from five of the six included studies were as follows: sensitivity: 91.06% (80.46% to 100%) and specificity: 91.96% (85.57% to 98.36%) for the detection of definite RHD only and sensitivity: 62.01% (31.80% to 92.22%) and specificity: 82.33% (65.15% to 99.52%) for the detection of borderline RHD only.ConclusionsHAND displayed good accuracy for detecting definite RHD only and modest accuracy for detecting any RHD but demonstrated poor accuracy for the detection of borderline RHD alone. Findings from this review provide some evidence for the potential of HAND to increase access to echocardiographic screening for RHD in resource-limited and remote settings; however, further research into feasibility and cost-effectiveness of wide-scale screening is still needed.PROSPERO registration numberCRD42016051261.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
J Francis ◽  
H Fairhurst ◽  
A Kaethner ◽  
G Whalley ◽  
C Ryan ◽  
...  

Abstract Introduction Echocardiographic screening can detect rheumatic heart disease (RHD) in high-risk populations,but is limited by reliance on highly-trained experts and equipment. We sought to determine the diagnostic utility of an ultra-abbreviated single parasternal-long-axis-sweep of the heart (SPLASH) echocardiography protocol to detect RHD, performed by briefly-trained health workers. Methods In Timor-Leste and Northern Australia, individuals aged 5–20y were offered school-based echocardiographic screening. Health workers completed online modules followed by one-week of practical training, logging 50 echocardiograms prior to study. The index test was SPLASH, performed and reported by health workers using handheld GE V-scan devices. The index test was abnormal if any mitral or aortic regurgitation was detected. The reference test was a comprehensive echocardiogram, performed by an echocardiographers or cardiologist on a GE Vivid-Q, reported according to World Heart Federation criteria. The diagnostic accuracy of the index test was determined. Results 2590 subjects underwent index and reference tests. Prevalence of definite RHD was 3.2% (83/2590). Sensitivity and specificity of index test were 0.75 (95% CI 0.64–0.83) and 0.77 (95% CI 0.75–0.78) respectively for detection of any definite RHD, and 0.91 (95% CI 0.74–0.98) and 0.76 (95% CI 0.74–0.78) respectively for detection of moderate or severe RHD. Conclusion Health workers using SPLASH detected the vast majority of moderate and severe RHD cases, but lacked sensitivity for detection of mild RHD. Further analysis is underway to evaluate the learning curve and other performance indicators of health workers performing and interpreting echocardiograms. This will allow refinement of SPLASH protocol and augmentation of health worker training to increase detection rates and accuracy for future population screening initiatives. Acknowledgement/Funding Heart Foundation Australia Vanguard Grant, Menzies HOT-NORTH pilot project grant, Snow Foundation, Rotary, Bawinanga Aboriginal Corporation, Mala'la


BMJ Open ◽  
2018 ◽  
Vol 8 (2) ◽  
pp. e020140 ◽  
Author(s):  
Lisa H Telford ◽  
Leila H Abdullahi ◽  
Eleanor A Ochodo ◽  
Liesl J Zühlke ◽  
Mark E Engel

IntroductionRheumatic heart disease (RHD) is a preventable and treatable chronic condition which persists in many developing countries largely affecting impoverished populations. Handheld echocardiography presents an opportunity to address the need for more cost-effective methods of diagnosing RHD in developing countries, where the disease continues to carry high rates of morbidity and mortality. Preliminary studies have demonstrated moderate sensitivity as well as high specificity and diagnostic odds for detecting RHD in asymptomatic patients. We describe a protocol for a systematic review on the diagnostic performance of handheld echocardiography compared to standard echocardiography using the 2012 World Heart Federation criteria for diagnosing subclinical RHD.Methods and analysisElectronic databases including PubMed, Scopus, Web of Science and EBSCOhost as well as reference lists and citations of relevant articles will be searched from 2012 to date using a predefined strategy incorporating a combination of Medical Subject Heading terms and keywords. The methodological validity and quality of studies deemed eligible for inclusion will be assessed against review specific Quality Assessment of Diagnostic Accuracy Studies 2 criteria and information on metrics of diagnostic accuracy and demographics extracted. Forest plots of sensitivity and specificity as well as scatter plots in receiver operating characteristic (ROC) space will be used to investigate heterogeneity. If possible, a meta-analysis will be conducted to produce summary results of sensitivity and specificity using the Hierarchical Summary ROC method. In addition, a sensitivity analysis will be conducted to investigate the effect of studies with a high risk of bias.Ethics and disseminationEthics approval is not required for this systematic review of previously published literature. The planned review will provide a summary of the diagnostic accuracy of handheld echocardiography. Results may feed into evidence-based guidelines and should the findings of this review warrant a change in clinical practice, a summary report will be disseminated among leading clinicians and healthcare professionals in the field.PROSPERO registration numberCRD42016051261.


BMJ Open ◽  
2020 ◽  
Vol 10 (5) ◽  
pp. e037609
Author(s):  
Joshua Reginald Francis ◽  
Helen Fairhurst ◽  
Gillian Whalley ◽  
Alex Kaethner ◽  
Anna Ralph ◽  
...  

IntroductionRheumatic heart disease (RHD) causes significant morbidity and mortality in young people from disadvantaged populations. Early detection through echocardiography screening can facilitate early access to treatment. Large-scale implementation of screening could be feasible with the combination of inexpensive standalone ultrasound transducers and upskilling non-expert practitioners to perform abbreviated echocardiography.Methods and analysisA prospective cross-sectional study will evaluate an abbreviated echocardiography screening protocol for the detection of latent (asymptomatic) RHD in high-risk populations. The study will evaluate the diagnostic accuracy of health worker conducted single parasternal long axis view with a sweep using handheld devices (SPLASH) (Philips Lumify S4-1 phased array transducer). Each participant will have at least one reference test performed on the same day by an expert echocardiographer. Diagnosis of RHD will be determined by a panel of three experts, using 2012 World Heart Federation criteria. Sensitivity and specificity of the index test will be calculated with 95% CIs, to determine diagnostic accuracy of a screen-and-refer approach to echocardiography screening for RHD. Remote review of SPLASH images obtained by health workers will facilitate evaluation of the sensitivity and specificity of an alternative approach, using external review of health worker obtained SPLASH images to decide onward referral.Ethics and disseminationEthics approval was obtained from the Human Research Ethics Committee of the Northern Territory Department of Health and Menzies School of Health Research, for the project to be carried out in Timor-Leste (HREC 2019-3399), and in Australia, following review by the Aboriginal Ethics subcommittee (HREC 2019-334). Ethical and technical approval was granted in Timor-Leste, by the Institute National of Health Research Ethics and Technical Committee (1073-MS-INS/GDE/VII/2019). Study results will be disseminated in the communities involved in the study, and through peer-reviewed publications and conference abstracts.Trial registration numberThe Australia New Zealand Clinical Trials Registry (ACTRN12620000122954).


2016 ◽  
Vol 4 (6) ◽  
pp. e386-e394 ◽  
Author(s):  
Daniel Engelman ◽  
Joseph H Kado ◽  
Bo Reményi ◽  
Samantha M Colquhoun ◽  
Jonathan R Carapetis ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document