Numerical investigation of fouling on cross-flow heat exchanger tubes with conjugated heat transfer approach

Author(s):  
Y. Kaptan ◽  
E. Buyruk ◽  
A. Ecder
2018 ◽  
Vol 225 ◽  
pp. 01023
Author(s):  
T.M. Yusof ◽  
M.F. Basrawi ◽  
A. Shahrani ◽  
H. Ibrahim

Ground heat exchanger is an exciting technique to reduce energy consumption in building especially in hot climate countries. Implementation of GHE for commercial unit in Malaysia is almost none in record. Thus, performance study of the GHE in Malaysia is crucial to be conducted either experimentally or numerically. Therefore, this paper presents the performance of GHE in term of effectiveness, outlet temperature and rate of heat transfer based on mathematical model. The model is developed based on cross flow heat exchanger with one fluid unmixed. There are two variable parameter used in the analysis which is effectiveness and flowrate of the air for 25 meter length of a PVC pipe. Three effectiveness values which is 0.8, 0.9 and 0.99 have been analysed in this study. Meanwhile, flowrate of air is ranging from 0.02 to 0.2 kg/s. Results show that flowrate at 0.02 kg/s gives great temperature reduction in the pipe compared with higher flowrate. However, flowrate of 0.2 kg/s produces higher cooling potential. Characteristic of the GHE for the rate of heat transfer with 80, 90 and 99 percent effectiveness also have been developed and it has been found that effectiveness of 0.9 provide good combination between flowrate and the rate of heat transfer for 25 meter length of the pipe


2011 ◽  
Vol 32 (1) ◽  
pp. 20-32 ◽  
Author(s):  
Isak Kotcioglu ◽  
Ahmet Cansiz ◽  
Sinan Caliskan ◽  
Senol Baskaya

Energies ◽  
2021 ◽  
Vol 14 (17) ◽  
pp. 5489
Author(s):  
Karthik Silaipillayarputhur ◽  
Tawfiq Al-Mughanam

All process industries involve the usage of heat exchanger equipment and understanding its performance during the design phase is very essential. The present research work specifies the performance of a pure cross flow heat exchanger in terms of dimensionless factors such as number of transfer units, capacity rate ratio, and heat exchanger effectiveness. Steady state sensible heat transfer was considered in the analysis. The matrix approach that was established in the earlier work was used in the study. The results were depicted in the form of charts, tables, and performance equations. It was observed that indeterminately increasing the number of transfer units past a threshold limit provided very marginal improvement in the performance of a pure cross flow heat exchanger. Likewise, flow pattern in a heat exchanger is usually assumed either as mixed or unmixed. However, due to various operating conditions, partially mixed conditions do exist. This work considers partially mixed conditions in the tube side of the heat exchanger. The correction factor for heat exchanger effectiveness was developed to accommodate partially mixed flow conditions in the pure cross flow heat exchanger.


Author(s):  
Mohammed Al Arfaj ◽  
Nasser Al Mulhim ◽  
Abdullah Al Mulhim ◽  
Ahmed Al Naim

The manuscript reviews the various steps involved in the design of a cross flow heat exchanger. Performance charts describing the thermal performance of the heat exchanger in terms of dimensionless parameters are used to develop the preliminary design of the heat exchanger. The preliminary design involves choosing the required number of heat exchanger passes, the required number of transfer units (NTU) and the capacity rate ratio for a given heat transfer application. These dimensionless parameters account for material, flow and thermal characteristics of the heat exchanger. In addition, NTU accounts for heat exchanger size, flow configuration and the type of heat exchanger. Since the preliminary design accounts for all the major characteristics of the heat exchanger, this approach is beneficial in optimizing the heat exchanger during the design phase. Performance charts indicate that indefinitely increasing the surface area (or NTU) does not increase the rate of heat transfer. There exists a threshold limit beyond which increasing the surface area adds no benefit to the heat exchanger. Instead, it just adds weight, material and cost of the heat exchanger. It must be noted that an undersized heat exchanger for a given application may not deliver the required heat transfer and while an oversized heat exchanger will increase the capital cost. Hence, it is very important to choose the right parameters during design of a heat exchanger. From the preliminary design, the detailed design for the heat exchanger can be readily extrapolated. The benefits of using performance charts in the design of a cross flow heat exchanger are described in the manuscript.


2020 ◽  
Vol 15 (57) ◽  
pp. 1057-1068
Author(s):  
Eslam Usama ◽  
Nabil Abd el Aziz ◽  
Walid aboelsoud ◽  
Ahmed Mohammed

2018 ◽  
Vol 41 (5) ◽  
pp. 500-510 ◽  
Author(s):  
M. Meikandan ◽  
M. Sundarraj ◽  
D. Yogaraj ◽  
K. Malarmohan

Sign in / Sign up

Export Citation Format

Share Document