Experimental optimization of a fan-shaped film cooling hole with 30 degrees-injection angle and 6-hole length-to-diameter ratio

Author(s):  
Sang Hyeon Park ◽  
Young Jun Kang ◽  
Hyun Jae Seo ◽  
Jae Su Kwak ◽  
Young Seok Kang
Author(s):  
Rui Zhu ◽  
Gongnan Xie ◽  
Terrence W. Simon

Secondary holes to a main film cooling hole are used to improve film cooling performance by creating anti-kidney vortices. The effects of injection angle of the secondary holes on both film cooling effectiveness and surrounding thermal and flow fields are investigated in this numerical study. Two kinds of primary hole shapes are adopted. One is a cylindrical hole, the other is a horn-shaped hole which is designed from a cylindrical hole by expanding the hole in the transverse direction to double the hole size at the exit. Two smaller cylindrical holes, the secondary holes, are located symmetrically about the centerline and downstream of the primary hole. Three compound injection angles (α = 30°, 45° and 60°, β = 30°) of the secondary holes are analyzed while the injection angle of the primary hole is kept at 45°. Cases with various blowing ratios are computed. It is shown from the simulation that cooling effectiveness of secondary holes with a horn-shaped primary hole is better than that with a cylindrical primary hole, especially at high blowing ratios. With a cylindrical primary hole, increasing inclination angle of the secondary holes provides better cooling effectiveness because the anti-kidney vortices created by shallow secondary holes cannot counteract the kidney vortex pairs adequately, enhancing mixing of main flow and coolant. For secondary holes with a horn-shaped primary hole, large secondary hole inclination angles provide better cooling performance at low blowing ratios; but, at high blowing ratios, secondary holes with small inclination angles are more effective, as the film coverage becomes wider in the downstream area.


Author(s):  
Ki-Don Lee ◽  
Kwang-Yong Kim

Shape optimization of a laidback fan-shaped film-cooling hole has been performed by surrogate-based optimization techniques using three-dimensional Reynolds-averaged Navier-Stokes analysis. Spatially-averaged film-cooling effectiveness has been maximized for the optimization. The injection angle of the hole, the lateral expansion angle of the diffuser, the forward expansion angle of the hole, and the ratio of the length to the diameter of the hole are chosen as design variables, and thirty-five experimental points within design space are selected by Latin hypercube sampling. Basic surrogate models, such as second-order polynomial response approximation (RSA), Kriging meta-modeling technique, radial basis neural network (RBNN), are constructed using the analysis results, and the PBA model is composed from these basic surrogate models with the weights being calculated for each basic surrogate. The optimal points are searched from the above constructed surrogates by sequential programming (SQP). It is shown that use of multiple surrogates increases the robustness in prediction of better design with minimum computational cost.


2014 ◽  
Vol 137 (2) ◽  
Author(s):  
Luzeng Zhang ◽  
Juan Yin ◽  
Hee Koo Moon

The effects of airfoil showerhead (SH) injection angle and film-cooling hole compound angle on nozzle endwall cooling (second order film-cooling effects, also called "phantom cooling") were experimentally investigated in a scaled linear cascade. The test cascade was built based on a typical industrial gas turbine nozzle vane. Endwall surface phantom cooling film effectiveness measurements were made using a computerized pressure sensitive paint (PSP) technique. Nitrogen gas was used to simulate cooling flow as well as a tracer gas to indicate oxygen concentration such that film effectiveness can be obtained by the mass transfer analogy. Two separate nozzle test models were fabricated, which have the same number and size of film-cooling holes but different configurations. One had a SH angle of 45 deg and no compound angles on the pressure and suction side (SS) film holes. The other had a 30 deg SH angle and 30 deg compound angles on the pressure and SS film-cooling holes. Nitrogen gas (cooling air) was fed through nozzle vanes, and measurements were conducted on the endwall surface between the two airfoils where no direct film cooling was applied. Six cooling mass flow ratios (MFRs, blowing ratios) were studied, and local (phantom) film effectiveness distributions were measured. Film effectiveness distributions were pitchwise averaged for comparison. Phantom cooling on the endwall by the SS film injections was found to be insignificant, but phantom cooling on the endwall by the pressure side (PS) airfoil film injections noticeably helped the endwall cooling (phantom cooling) and was a strong function of the MFR. It was concluded that reducing the SH angle and introducing a compound angle on the PS injections would enhance the endwall surface phantom cooling, particularly for a higher MFR.


Author(s):  
J. Dittmar ◽  
A. Schulz ◽  
S. Wittig

The demand of improved thermal efficiency and high power output of modern gas turbine engines leads to extremely high turbine inlet temperatures and pressure ratios. Sophisticated cooling schemes including film cooling are widely used to protect vanes and blades from failure and to achieve high component life-times. Besides standard cylindrical cooling hole geometry, shaped injection holes are used in modern film cooling applications in order to improve cooling performance and to reduce the necessary cooling air flow. However, complex hole shapes may lead to manufacturing constraints and high costs. This paper evaluates some film cooling injection geometry with different complexity. The comparison is based on measurements of the adiabatic film cooling effectiveness and the heat transfer coefficient downstream of the injection location. In total, 4 different film cooling hole configurations are investigated: A single row of fanshaped holes with and without a compound injection angle, a double row of cylindrical holes and a double row of discrete slots, both in staggered arrangement. All holes are inclined 45° with respect to the model’s surface. During the measurements, the influence of coolant blowing ratio is determined. Additionally, the influence of cooling air feeding direction into the fanshaped holes with the compound injection angle is investigated. An infrared thermography measurement system is used for highly resolved mappings of the model’s surface temperature. Accurate local temperature data is achieved by an In-Situ calibration procedure with the help of single thermocouples embedded in the test plate. A subsequent finite elements heat conduction analysis takes three-dimensional heat fluxes inside the test plate into account.


1994 ◽  
Vol 116 (3) ◽  
pp. 358-368 ◽  
Author(s):  
J. H. Leylek ◽  
R. D. Zerkle

Large-scale computational analyses have been conducted and results compared with experiments to understand coolant jet and crossflow interaction in discrete-jet film cooling. Detailed three-dimensional elliptic Navier–Stokes solutions, with high-order turbuence modeling, are presented for film cooling using a new model enabling simultaneous solution of fully coupled flow in plenum, film-hole, and cross-stream regions. Computations are carried out for the following range of film cooling parameters typically found in gas turbine airfoil applications: single row of jets with a film-hole length-to-diameter ratio of 1.75 and 3.5; blowing ratio from 0.5 up to 2; coolant-to-crossflow density ratio of 2; streamwise injection angle of 35 deg; and pitch-to-diameter ratio of 3. Comparison of computational solutions with experimental data give good agreement. Moreover, the current results complement experiments and support previous interpretations of measured data and flow visualization. The results also explain important aspects of film cooling, such as the development of complex flow within the film-hole in addition to the well-known counterrotating vortex structure in the cross-stream.


Author(s):  
Yongbin Ji ◽  
Prashant Singh ◽  
Srinath V. Ekkad ◽  
Shusheng Zhang

Film cooling behavior of a single cylindrical hole inclined at an angle of 35° with respect to a flat surface is numerically predicted in this study. Adiabatic film cooling effectiveness has been presented to evaluate the influence of the scoop placed on the coolant entry side. The effect of blowing ratio (0.65, 1, 1.5 and 2) and the length-to-diameter ratio (1.7 and 4.4) are examined. Three-dimensional Reynolds-averaged Navier-Stokes analysis with SST turbulence model is used for the computations. It has been found that both centerline and laterally averaged adiabatic film cooling effectiveness are enhanced by the scoop and the enhancement increases with the blowing ratio in the investigated range of variables. The scoop was more effective for the higher length-to-diameter ratio cases (L/D = 4.4) because of better velocity distribution at the film hole exit, which makes coolant reattach at a more upstream location after blowing off from the wall.


Sign in / Sign up

Export Citation Format

Share Document