Optimization of the airside thermal performance of mini-channel-flat-tube radiators by using composite straight-and-louvered fins

Author(s):  
Ngoctan Tran ◽  
Chi-Chuan Wang
2019 ◽  
Vol 250 ◽  
pp. 1280-1291 ◽  
Author(s):  
C.Q. Chen ◽  
Y.H. Diao ◽  
Y.H. Zhao ◽  
W.H. Ji ◽  
Z.Y. Wang ◽  
...  

2021 ◽  
Vol 14 (2) ◽  
pp. 106-111
Author(s):  
Ridho Syahrul ◽  
Amnur Akhyan

Penelitian ini menggunakan metode ɛ-NTU untuk menganalisis data. Radiator yang digunakan adalah radiator sepeda motor Yamaha Nmax 155cc dengan jenis aliran vertical, flat tube dan louvered fins, kipas/fan sebagai sumber angin simulasi, dengan campuran 50% air + 50% coolant radiator. Laju aliran air konstan 4 lpm dan temperatur fluida panas konstan 80. Variasi kecepatan aliran udara yang digunakan pada pengujian kali ini adalah 4-8 m/s dan diatur menggunakan Dimmer sebagai alat bantu. Dari pengujian yang telah dilakukan didapat laju massa aliran udara yang paling besar terjadi pada kecepatan kipas 8 m/s. Laju perpindahan panas yang paling besar terjadi dikecepatan kipas 8 m/s sebesar 0,0735 kW dan panas menyeluruh terbesar juga terjadi dikecepatan kipas 8 m/s yaitu sebesar 9,50 W/m2°C. Efisiensi radiator maksimum terjadi pada kecepatan kipas 5 m/s dengan nilai sebesar 7,59. Kata kunci: Efektifitas, Metode ε-NTU, Radiator Nmax 155cc. This study uses the ε-NTU method to analyze the data. The radiator used is a 155cc Yamaha Nmax motorcycle radiator with vertical flow type, flat tube and louvered fins, fan/fan as a simulation source, with a mixture of 50% water + 50% coolant radiator. The water flow rate is constant 4 lpm and the hot fluid temperature is constant 80℃. The variation of air flow velocity used in this test is 4-8 m/s and is adjusted using a dimmer as a tool. From the tests that have been carried out, the largest air flow rate occurs at a fan speed of 8 m/s. The highest heat transfer rate occurs at a fan speed of 8 m/s at 0.0735 kW and the largest overall heat also occurs at a fan speed of 8 m/s at 9.50 W/m2°C. The maximum radiator efficiency occurs at a fan speed of 5 m/s with a value of 7.59 Keywords: Effectivenes, ɛ-NTU Method, Nmax 155cc Radiator


2020 ◽  
Vol 92 (3) ◽  
pp. 30901
Author(s):  
Suvanjan Bhattacharyya ◽  
Debraj Sarkar ◽  
Ulavathi Shettar Mahabaleshwar ◽  
Manoj K. Soni ◽  
M. Mohanraj

The current study experimentally investigates the heat transfer augmentation on the novel axial corrugated heat exchanger tube in which the spring tape is introduced. Air (Pr = 0.707) is used as a working fluid. In order to augment the thermohydraulic performance, a corrugated tube with inserts is offered. The experimental study is further extended by varying the important parameters like spring ratio (y = 1.5, 2.0, 2.5) and Reynolds number (Re = 10 000–52 000). The angular pitch between the two neighboring corrugations and the angle of the corrugation is kept constant through the experiments at β = 1200 and α = 600 respectively, while two different corrugations heights (h) are analyzed. While increasing the corrugation height and decreasing the spring ratio, the impact of the swirling effect improves the thermal performance of the system. The maximum thermal performance is obtained when the corrugation height is h = 0.2 and spring ratio y = 1.5. Eventually, correlations for predicting friction factor (f) and Nusselt number (Nu) are developed.


2019 ◽  
Vol 50 (8) ◽  
pp. 757-772 ◽  
Author(s):  
Yicang Huang ◽  
Hui Li ◽  
Shengnan Shen ◽  
Yongbo Xue ◽  
Mingliang Xu ◽  
...  