Ultrahigh broadband absorption in metamaterials with electric and magnetic polaritons enabled by multiple materials

Author(s):  
Zhaolong Wang ◽  
Zhen Liu ◽  
Guihui Duan ◽  
Leyuan Fang ◽  
Huigao Duan
2018 ◽  
Author(s):  
Y. H. Kan ◽  
Changying Zhao ◽  
Zhuomin M. Zhang

2020 ◽  
Vol 59 (11) ◽  
pp. 110906
Author(s):  
Juan Shen ◽  
Yong Ren ◽  
Xinxin Zhu ◽  
Min Mao ◽  
Quan Zhou ◽  
...  

Molecules ◽  
2020 ◽  
Vol 25 (4) ◽  
pp. 781
Author(s):  
Ernesto Enríquez-Palacios ◽  
Teresa Arbeloa ◽  
Jorge Bañuelos ◽  
Claudia I. Bautista-Hernández ◽  
José G. Becerra-González ◽  
...  

Herein we report on a straightforward access method for boron dipyrromethene dyes (BODIPYs)-coumarin hybrids linked through their respective 8- and 6- positions, with wide functionalization of the coumarin fragment, using salicylaldehyde as a versatile building block. The computationally-assisted photophysical study unveils broadband absorption upon proper functionalization of the coumarin, as well as the key role of the conformational freedom of the coumarin appended at the meso position of the BODIPY. Such free motion almost suppresses the fluorescence signal, but enables us to apply these dyads as molecular rotors to monitor the surrounding microviscosity.


Photonics ◽  
2021 ◽  
Vol 8 (4) ◽  
pp. 114
Author(s):  
Steve Kamau ◽  
Safaa Hassan ◽  
Khadijah Alnasser ◽  
Hualiang Zhang ◽  
Jingbiao Cui ◽  
...  

It is challenging to realize the complete broadband absorption of near-infrared in thin optical devices. In this paper, we studied high light absorption in two devices: a stack of Au-pattern/insulator/Au-film and a stack of Au-pattern/weakly-absorbing-material/Au-film where the Au-pattern was structured in graded photonic super-crystal. We observed multiple-band absorption, including one near 1500 nm, in a stack of Au-pattern/spacer/Au-film. The multiple-band absorption is due to the gap surface plasmon polariton when the spacer thickness is less than 30 nm. Broadband absorption appears in the near-infrared when the insulator spacer is replaced by a weakly absorbing material. E-field intensity was simulated and confirmed the formation of gap surface plasmon polaritons and their coupling with Fabry–Pérot resonance.


Author(s):  
Yadgar I. Abdulkarim ◽  
Halgurd N. Awl ◽  
Fatih Ozkan Alkurt ◽  
Fahmi F. Muhammadsharif ◽  
Salah Raza Saeed ◽  
...  

2014 ◽  
Vol 330 ◽  
pp. 135-139 ◽  
Author(s):  
R. Miloua ◽  
Z. Kebbab ◽  
F. Chiker ◽  
M. Khadraoui ◽  
K. Sahraoui ◽  
...  

2021 ◽  
Vol 528 ◽  
pp. 167720
Author(s):  
Jing Zhang ◽  
Yuchang Su ◽  
Qiushan Yu ◽  
Zhongbao Luo ◽  
Hongzhi Zhang

Molecules ◽  
2021 ◽  
Vol 26 (13) ◽  
pp. 3820
Author(s):  
Heidi Fleischer ◽  
Christoph Lutter ◽  
Andreas Büttner ◽  
Wolfram Mittelmeier ◽  
Kerstin Thurow

The endoprosthetic care of hip and knee joints introduces multiple materials into the human body. Metal containing implant surfaces release degradation products such as particulate wear and corrosion debris, metal-protein complexes, free metallic ions, inorganic metal salts or oxides. Depending on the material composition of the prostheses, a systemic exposure occurs and may result in increasing metal concentrations in body fluids and tissues especially in the case of malfunctions of the arthroplasty components. High concentrations of Cr, Co, Ni, Ti and Al affect multiple organs such as thyroid, heart, lung and cranial nerves and may lead to metallosis, intoxications, poly-neuropathy, retinopathy, cardiomyopathy and the formation of localized pseudo tumors. The determination of the concentration of metals in body fluids and tissues can be used for predicting failure of hip or knee replacements to prevent subsequent severe intoxications. A semi-automated robot-assisted measurement system is presented for the determination of heavy metals in human tissue samples using inductively coupled plasma mass spectrometry (ICP-MS). The manual and automated measurement processes were similarly validated using certified reference material and the results are compared and discussed. The automation system was successfully applied in the determination of heavy metals in human tissue; the first results are presented.


Sign in / Sign up

Export Citation Format

Share Document