Numerical prediction of operating characteristics of micro-gas turbine combustor with on-board reformed EGR system using co-simulation model and 1D reduced model

Author(s):  
Jonghyun Kim ◽  
Hookyung Lee ◽  
Jungsoo Park
2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Kirubakaran V. ◽  
David Bhatt

Purpose The lean blowout (LBO) limit of the combustor is one of the important performance parameters for any gas turbine combustor design. This study aims to predict the LBO limits of an in-house designed swirl stabilized 3kW can-type micro gas turbine combustor. Design/methodology/approach The experimental prediction of LBO limits was performed on 3kW swirl stabilized combustor fueled with methane for the combustor inlet velocity ranging from 1.70 m/s to 6.80 m/s. The numerical prediction of LBO limits of combustor was performed on two-dimensional axisymmetric model. The blowout limits of combustor were predicted through calculated average exit gas temperature (AEGT) method and compared with experimental predictions. Findings The results show that the predicted LBO equivalence ratio decreases gradually with an increase in combustor inlet velocity. Practical implications This LBO limits predictions will use to fix the operating boundary conditions of 3kW can-type micro gas turbine combustor. This methodology will be used in design stage as well as in the testing stage of the combustor. Originality/value This is a first effort to predict the LBO limits on micro gas turbine combustor through AEGT method. The maximum uncertainty in LBO limit prediction with AEGT is 6 % in comparison with experimental results.


2008 ◽  
Vol 3 (1) ◽  
pp. 204-215
Author(s):  
Kousaku YOTORIYAMA ◽  
Shunsuke AMANO ◽  
Hidetomo FUJIWARA ◽  
Tomohiko FURUHATA ◽  
Masataka ARAI

Author(s):  
Masato Hiramatsu ◽  
Yoshifumi Nakashima ◽  
Sadamasa Adachi ◽  
Yudai Yamasaki ◽  
Shigehiko Kaneko

One approach to achieving 99% combustion efficiency (C.E.) and 10 ppmV or lower NOx (at 15%O2) in a micro gas turbine (MGT) combustor fueled by biomass gas at a variety of operating conditions is with the use of flameless combustion (FLC). This paper compares experimentally obtained results and CHEMKIN analysis conducted for the developed combustor. As a result, increase the number of stage of FLC combustion enlarges the MGT operation range with low-NOx emissions and high-C.E. The composition of fuel has a small effect on the characteristics of ignition in FLC. In addition, NOx in the engine exhaust is reduced by higher levels of CO2 in the fuel.


2017 ◽  
Vol 140 (2) ◽  
Author(s):  
Andreas Schwärzle ◽  
Thomas O. Monz ◽  
Andreas Huber ◽  
Manfred Aigner

Jet-stabilized combustion is a promising technology for fuel flexible, reliable, highly efficient combustion systems. The aim of this work is a reduction of NOx emissions of a previously published two-stage micro gas turbine (MGT) combustor (Zanger et al., 2015, “Experimental Investigation of the Combustion Characteristics of a Double-Staged FLOX-Based Combustor on an Atmospheric and a Micro Gas Turbine Test Rig,” ASME Paper No. GT2015-42313 and Schwärzle et al., 2016, “Detailed Examination of Two-Stage Micro Gas Turbine Combustor,” ASME Paper No. GT2016-57730), where the pilot stage (PS) of the combustor was identified as the main contributor to NOx emissions. The geometry optimization was carried out regarding the shape of the pilot dome and the interface between PS and main stage (MS) in order to prevent the formation of high-temperature recirculation zones. Both stages have been run separately to allow a detailed understanding of the flame stabilization within the combustor, its range of stable combustion, the interaction between both stages, and the influence of the modified geometry. All experiments were conducted at atmospheric pressure and an air preheat temperature of 650  °C. The flame was analyzed in terms of shape, length, and lift-off height, using OH* chemiluminescence (OH-CL) images. Emission measurements for NOx, CO, and unburned hydrocarbons (UHC) emissions were carried out. At a global air number of λ = 2, a fuel split variation was carried out from 0 (only PS) to 1 (only MS). The modification of the geometry leads to a decrease in NOx and CO emissions throughout the fuel split variation in comparison with the previous design. Regarding CO emissions, the PS operations are beneficial for a fuel split above 0.8. The local maximum in NOx emissions observed for the previous combustor design at a fuel split of 0.78 was not apparent for the modified design. NOx emissions were increasing, when the local air number of the PS was below the global air number. In order to evaluate the influence of the modified design on the flow field and identify the origin of the emission reduction compared to the previous design, unsteady Reynolds-averaged Navier–Stokes simulations were carried out for both geometries at fuel splits of 0.93 and 0.78, respectively, using the DLR (German Aerospace Center) in-house code turbulent heat release extension of the tau code (theta) with the k–ω shear stress transport turbulence model and the DRM22 (Kazakov and Frenklach, 1995, “DRM22,” University of California at Berkeley, Berkeley, CA, accessed Sept. 21, 2017, http://www.me.berkeley.edu/drm/) detailed reaction mechanism. The numerical results showed a strong influence of the recirculation zones on the PS reaction zone.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Vedant Dwivedi ◽  
Srikanth Hari ◽  
S. M. Kumaran ◽  
B. V. S. S. S. Prasad ◽  
Vasudevan Raghavan

Abstract Experimental and numerical study of flame and emission characteristics in a tubular micro gas turbine combustor is reported. Micro gas turbines are used for distributed power (DP) generation using alternative fuels in rural areas. The combustion and emission characteristics from the combustor have to be studied for proper design using different fuel types. In this study methane, representing fossil natural gas, and biogas, a renewable fuel that is a mixture of methane and carbon-dioxide, are used. Primary air flow (with swirl component) and secondary aeration have been varied. Experiments have been conducted to measure the exit temperatures. Turbulent reactive flow model is used to simulate the methane and biogas flames. Numerical results are validated against the experimental data. Parametric studies to reveal the effects of primary flow, secondary flow and swirl have been conducted and results are systematically presented. An analysis of nitric-oxides emission for different fuels and operating conditions has been presented subsequently.


2011 ◽  
Vol 33 (2) ◽  
pp. 3293-3300 ◽  
Author(s):  
Shoichi Tanaka ◽  
Masayasu Shimura ◽  
Naoya Fukushima ◽  
Mamoru Tanahashi ◽  
Toshio Miyauchi

Author(s):  
Marco Badami ◽  
Mauro Ferrero ◽  
Armando Portoraro

The paper deals with a simulation model, developed in Matlab Simulink®, of a small-scale Combined Heat and Power (CHP) plant based on a recuperated micro gas turbine (mGT). A minimum data set, mainly obtainable from datasheets, was defined, that allows the model to simulate different mGT plants in the small-scale range with a good accuracy. The model implements the mass, energy and momentum equations of the main components of the power plant. A double control system has also been developed, with the aim of maintaining the rotational speed of the turbine /compressor assembly at the nominal fixed value, and at limiting the Exhaust Gas Temperature (EGT) below the limit value. The model has been validated by means of experimental data obtained from a commercial mGT (100 kWel, 170 kWth), installed at the Politecnico di Torino, whose energetic characterization has been performed both at rated and at partial load conditions. The layout and the characteristics of the measurement system are also described in the paper.


2005 ◽  
Vol 2005.3 (0) ◽  
pp. 5-6
Author(s):  
Kousaku YOTORIYAMA ◽  
Shunsuke AMANO ◽  
Hidetomo FUJIWARA ◽  
Tomohiko FURUHATA ◽  
Masataka ARAI

Sign in / Sign up

Export Citation Format

Share Document