scholarly journals Field evaluation of a novel loop mediated isothermal amplification (LAMP) assay for molecular diagnosis of asymtomatic malaria in a field setting in sub-Saharan Africa

2016 ◽  
Vol 45 ◽  
pp. 155
Author(s):  
E.C. Oriero ◽  
J. Jacobs ◽  
J.-P. Van Geertruyden ◽  
D.C. Nwakanma ◽  
U. D’Alessandro
2020 ◽  
Vol 94 ◽  
Author(s):  
M.G. Ngari ◽  
I.N. Mwangi ◽  
M.P. Njoroge ◽  
J. Kinyua ◽  
F.A. Osuna ◽  
...  

Abstract Whipworm infection or trichuriasis caused by Trichuris trichiura is of major public health concern in sub-Saharan Africa, particularly among pre-school and school-going children. It is among the neglected tropical diseases targeted for elimination through mass drug administration (MDA). One of the outcomes of MDA is a rapid decline in levels of infection intensity, making it difficult to monitor effectiveness of control measures using the conventional Kato–Katz procedure, which relies on the microscopic detection of parasite ova in faecal samples. In the present study, a loop-mediated isothermal amplification (LAMP) test was developed for the detection of T. trichiura infection in faecal samples. LAMP technology offers greater sensitivity and specificity than the microscopy-based tests. A set of four specific primers targeting the internal transcribed spacer 2 region of the ribosomal DNA were designed using Primer Explorer software. DNA was extracted from faecal samples using the alkaline lysis method (HotSHOT) and the LAMP reaction performed at 63°C for 1 h. The amplicons were visualized by both gel electrophoresis and with the naked eye following staining with SYBR green dye. Sensitivity and specificity tests were determined using the standard Kato–Katz diagnostic procedure as a reference test. The developed LAMP assay reliably detected T. trichiura DNA in faecal samples, with a specificity and sensitivity of 88% and 77%, respectively. No cross-reactivity was observed with several common helminth parasites. The developed LAMP assay is an appropriate diagnostic method for the detection of T. trichiura DNA in human faecal samples due to its simplicity, low cost, high sensitivity and specificity.


2018 ◽  
Vol 3 (4) ◽  
pp. 124 ◽  
Author(s):  
Zhi-Qiang Qin ◽  
Jing Xu ◽  
Ting Feng ◽  
Shan Lv ◽  
Ying-Jun Qian ◽  
...  

Schistosoma infection in snails can be monitored by microscopy or indirectly by sentinel mice. As both these approaches can miss infections, more sensitive tests are needed, particularly in low-level transmission settings. In this study, loop-mediated isothermal amplification (LAMP) technique, designed to detect a specific 28S ribosomal Schistosoma japonicum (Sj28S) gene with high sensitivity, was compared to microscopy using snail samples from 51 areas endemic for schistosomiasis in five Chinese provinces. In addition, the results were compared with those from polymerase chain reaction (PCR) by adding DNA sequencing as a reference. The testing of pooled snail samples with the LAMP assay showed that a dilution factor of 1/50, i.e., one infected snail plus 49 non-infected ones, would still result in a positive reaction after the recommended number of amplification cycles. Testing a total of 232 pooled samples, emanating from 4006 snail specimens, showed a rate of infection of 6.5%, while traditional microscopy found only 0.4% positive samples in the same materials. Parallel PCR analysis confirmed the diagnostic accuracy of the LAMP assay, with DNA sequencing even giving LAMP a slight lead. Microscopy and the LAMP test were carried out at local schistosomiasis-control stations, demonstrating that the potential of the latter assay to serve as a point-of-care (POC) test with results available within 60–90 min, while the more complicated PCR test had to be carried out at the National Institute of Parasitic Diseases (NIPD) in Shanghai, China. In conclusion, LAMP was found to be clearly superior to microscopy and as good as, or better than, PCR. As it can be used under field conditions and requires less time than other techniques, LAMP testing would improve and accelerate schistosomiasis control.


Author(s):  
Zhi-Qiang Qin ◽  
Jing Xu ◽  
Ting Feng ◽  
Shan Lv ◽  
Yin-Jun Qian ◽  
...  

Schistosoma infection in snails can be monitored by microscopy or indirectly by sentinel mice. As both these approaches sometimes miss infections, more sensitive tests are needed, particularly in low-level transmission settings. In this study, the loop-mediated isothermal amplification (LAMP) technique, designed to detect a specific 28S ribosomal S. japonicum gene with high sensitivity, was compared to microscopy using snail samples from 51 areas endemic for schistosomiasis in five Chinese provinces. The results were compared with those by polymerase chain reaction (PCR) adding DNA sequencing as a reference when needed. The testing of pooled snail samples showed that a dilution factor of 1/50, i.e., one infected snail plus 49 non-infected ones, would still result in a positive reaction after the recommended number of amplification cycles. Testing a total of 232 pooled samples, emanating from 4,006 snail specimens, with the LAMP assay showed a 6.5% rate of infection, while traditional microscopy found only 0.04% positive samples in the same materials. Parallel PCR analysis confirmed the diagnostic accuracy of the LAMP assay, with DNA sequencing even giving LAMP a slight lead. Microscopy and the LAMP test were carried out at local schistosomiasis-control stations demonstrating that the potential of the latter assay to serve as a point-of-care (POC) test with results available within 60–90 minutes, while the more complicated PCR test had to be carried out at the National Institute of Parasitic Diseases (NIPD) in Shanghai, China. In conclusion, LAMP was found to be clearly superior to microscopy and as good as, or better, than PCR. Application of LAMP testing would be useful for surveillance and risk prediction as it requires less time than other techniques and can be used under field conditions, which improves and accelerates schistosomiasis control.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Somayyeh Sedaghatjoo ◽  
Monika K. Forster ◽  
Ludwig Niessen ◽  
Petr Karlovsky ◽  
Berta Killermann ◽  
...  

AbstractTilletia controversa causing dwarf bunt of wheat is a quarantine pathogen in several countries. Therefore, its specific detection is of great phytosanitary importance. Genomic regions routinely used for phylogenetic inferences lack suitable polymorphisms for the development of species-specific markers. We therefore compared 21 genomes of six Tilletia species to identify DNA regions that were unique and conserved in all T. controversa isolates and had no or limited homology to other Tilletia species. A loop-mediated isothermal amplification (LAMP) assay for T. controversa was developed based on one of these DNA regions. The specificity of the assay was verified using 223 fungal samples comprising 43 fungal species including 11 Tilletia species, in particular 39 specimens of T. controversa, 92 of T. caries and 40 of T. laevis, respectively. The assay specifically amplified genomic DNA of T. controversa from pure cultures and teliospores. Only Tilletia trabutii generated false positive signals. The detection limit of the LAMP assay was 5 pg of genomic DNA per reaction. A test performance study that included five laboratories in Germany resulted in 100% sensitivity and 97.7% specificity of the assay. Genomic regions, specific to common bunt (Tilletia caries and Tilletia laevis together) are also provided.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Severino Jefferson Ribeiro da Silva ◽  
Keith Pardee ◽  
Udeni B. R. Balasuriya ◽  
Lindomar Pena

AbstractWe have previously developed and validated a one-step assay based on reverse transcription loop-mediated isothermal amplification (RT-LAMP) for rapid detection of the Zika virus (ZIKV) from mosquito samples. Patient diagnosis of ZIKV is currently carried out in centralized laboratories using the reverse transcription-quantitative polymerase chain reaction (RT-qPCR), which, while the gold standard molecular method, has several drawbacks for use in remote and low-resource settings, such as high cost and the need of specialized equipment. Point-of-care (POC) diagnostic platforms have the potential to overcome these limitations, especially in low-resource countries where ZIKV is endemic. With this in mind, here we optimized and validated our RT-LAMP assay for rapid detection of ZIKV from patient samples. We found that the assay detected ZIKV from diverse sample types (serum, urine, saliva, and semen) in as little as 20 min, without RNA extraction. The RT-LAMP assay was highly specific and up to 100 times more sensitive than RT-qPCR. We then validated the assay using 100 patient serum samples collected from suspected cases of arbovirus infection in the state of Pernambuco, which was at the epicenter of the last Zika epidemic. Analysis of the results, in comparison to RT-qPCR, found that the ZIKV RT-LAMP assay provided sensitivity of 100%, specificity of 93.75%, and an overall accuracy of 95.00%. Taken together, the RT-LAMP assay provides a straightforward and inexpensive alternative for the diagnosis of ZIKV from patients and has the potential to increase diagnostic capacity in ZIKV-affected areas, particularly in low and middle-income countries.


3 Biotech ◽  
2021 ◽  
Vol 11 (2) ◽  
Author(s):  
Domenico Rizzo ◽  
Nicola Luchi ◽  
Daniele Da Lio ◽  
Linda Bartolini ◽  
Francesco Nugnes ◽  
...  

AbstractThe red-necked longhorn beetle Aromia bungii (Faldermann, 1835) (Coleoptera: Cerambycidae) is native to east Asia, where it is a major pest of cultivated and ornamental species of the genus Prunus. Morphological or molecular discrimination of adults or larval specimens is required to identify this invasive wood borer. However, recovering larval stages of the pest from trunks and branches causes extensive damage to plants and is timewasting. An alternative approach consists in applying non-invasive molecular diagnostic tools to biological traces (i.e., fecal pellets, frass). In this way, infestations in host plants can be detected without destructive methods. This paper presents a protocol based on both real-time and visual loop-mediated isothermal amplification (LAMP), using DNA of A. bungii extracted from fecal particles in larval frass. Laboratory validations demonstrated the robustness of the protocols adopted and their reliability was confirmed performing an inter-lab blind panel. The LAMP assay and the qPCR SYBR Green method using the F3/B3 LAMP external primers were equally sensitive, and both were more sensitive than the conventional PCR (sensitivity > 103 to the same starting matrix). The visual LAMP protocol, due to the relatively easy performance of the method, could be a useful tool to apply in rapid monitoring of A. bungii and in the management of its outbreaks.


Sign in / Sign up

Export Citation Format

Share Document