Near-infrared Triggered Ropivacaine Liposomal Gel for Adjustable and Prolonged Local Anaesthesia

Author(s):  
Yufei Hou ◽  
Xiangxue Meng ◽  
Shixin Zhang ◽  
Fengying Sun ◽  
Wenhua Liu
Vascular ◽  
2020 ◽  
Vol 28 (3) ◽  
pp. 301-308
Author(s):  
Donatas Inčiūra ◽  
Aleksandras Antuševas ◽  
Adomas Aladaitis ◽  
Agnė Gimžauskaitė ◽  
Linas Velička ◽  
...  

Objectives The aim of our study was to evaluate the near-infrared spectroscopy monitoring system to detect cerebral ischaemia, find indications for selective shunting during carotid endarterectomy and compare it with an internal carotid artery stump pressure monitoring technique in patients operated under local anaesthesia. Methods During January 2015 and November 2018, 131 patients undergoing carotid endarterectomy under local anaesthesia were prospectively included in the study. Near-infrared spectroscopy as intraoperative monitoring was applied and compared with stump pressure. Results Carotid endarterectomy was performed successfully in 106 patients operated under local anaesthesia. Meanwhile, 25 patients developed neurological changes (motor or consciousness impairment, weakness of extremities, cognitive decline) during clamping, and all of them received a shunt. ΔrSO2, stump pressure and rSO2 (–11 ± 8%, 31 ± 6mmHg, 58 ± 11) values were smaller in the group of shunted subjects versus non-shunted group subjects (–2 ± 5%, 61 ± 17 mmHg, 64 ± 8) after 1 min of internal carotid artery clamping ( p < 0.05). Statistical analysis showed a sensitivity of 90% (95% CI: 0.85–0.95) and a specificity of 70% (95% CI: 0.62–0.78) for a ≥10% drop in ΔrSO2 to predict ischaemia symptoms during carotid clamping. Using stump pressure with a cut-off value of ≤40 mmHg for predicting symptoms, the sensitivity was 82% and specificity 54%. Conclusions Near-infrared spectroscopy is a suitable non-invasive cerebral oxygenation monitoring method during carotid endarterectomy. A 10% decrease of ΔrSO2 had a good correlation with clinical cerebral ischaemia signs and matched well with the stump pressure cut-off value of ≤40 mmHg. There is a possibility of near-infrared spectroscopy to replace stump pressure in cerebral oxygenation monitoring during carotid endarterectomy. However, we need larger prospective multicentre studies to identify the optimal threshold for shunt requirement.


Nanoscale ◽  
2020 ◽  
Vol 12 (14) ◽  
pp. 7875-7887 ◽  
Author(s):  
Ying Lan ◽  
Xiaohui Zhu ◽  
Ming Tang ◽  
Yihan Wu ◽  
Jing Zhang ◽  
...  

A near-infrared (NIR) activated theranostic nanoplatform based on upconversion nanoparticles (UCNPs) is developed in order to overcome the hypoxia-associated resistance in photodynamic therapy by photo-release of NO upon NIR illumination.


2020 ◽  
Vol 56 (43) ◽  
pp. 5819-5822
Author(s):  
Jing Zheng ◽  
Yongzhuo Liu ◽  
Fengling Song ◽  
Long Jiao ◽  
Yingnan Wu ◽  
...  

In this study, a near-infrared (NIR) theranostic photosensitizer was developed based on a heptamethine aminocyanine dye with a long-lived triplet state.


2020 ◽  
Vol 48 (6) ◽  
pp. 2657-2667
Author(s):  
Felipe Montecinos-Franjola ◽  
John Y. Lin ◽  
Erik A. Rodriguez

Noninvasive fluorescent imaging requires far-red and near-infrared fluorescent proteins for deeper imaging. Near-infrared light penetrates biological tissue with blood vessels due to low absorbance, scattering, and reflection of light and has a greater signal-to-noise due to less autofluorescence. Far-red and near-infrared fluorescent proteins absorb light &gt;600 nm to expand the color palette for imaging multiple biosensors and noninvasive in vivo imaging. The ideal fluorescent proteins are bright, photobleach minimally, express well in the desired cells, do not oligomerize, and generate or incorporate exogenous fluorophores efficiently. Coral-derived red fluorescent proteins require oxygen for fluorophore formation and release two hydrogen peroxide molecules. New fluorescent proteins based on phytochrome and phycobiliproteins use biliverdin IXα as fluorophores, do not require oxygen for maturation to image anaerobic organisms and tumor core, and do not generate hydrogen peroxide. The small Ultra-Red Fluorescent Protein (smURFP) was evolved from a cyanobacterial phycobiliprotein to covalently attach biliverdin as an exogenous fluorophore. The small Ultra-Red Fluorescent Protein is biophysically as bright as the enhanced green fluorescent protein, is exceptionally photostable, used for biosensor development, and visible in living mice. Novel applications of smURFP include in vitro protein diagnostics with attomolar (10−18 M) sensitivity, encapsulation in viral particles, and fluorescent protein nanoparticles. However, the availability of biliverdin limits the fluorescence of biliverdin-attaching fluorescent proteins; hence, extra biliverdin is needed to enhance brightness. New methods for improved biliverdin bioavailability are necessary to develop improved bright far-red and near-infrared fluorescent proteins for noninvasive imaging in vivo.


1997 ◽  
Vol 62 (26) ◽  
pp. 9387-9387 ◽  
Author(s):  
Narasimhachari Narayanan ◽  
Lucjan Strekowski ◽  
Malgorzata Lipowska ◽  
Gabor Patonay

VASA ◽  
2009 ◽  
Vol 38 (3) ◽  
pp. 225-233 ◽  
Author(s):  
Aleksic ◽  
Luebke ◽  
Brunkwall

Background: In the present study the perioperative complication rate is compared between high- and low-risk patients when carotid endarterectomy (CEA) is routinely performed under local anaesthesia (LA). Patients and methods: From January 2000 through June 2008 1220 consecutive patients underwent CEA under LA. High-risk patients fulfilled at least one of the following characteristics: ASA 4 classification, “hostile neck”, recurrent ICA stenosis, contralateral ICA occlusion, age ≥ 80 years. The combined complication rate comprised any new neurological deficit (TIA or stroke), myocardial infarction or death within 30 days after CEA, which was compared between patient groups. Results: Overall 309 patients (25%) were attributed to the high-risk group, which differed significantly regarding sex distribution (more males: 70% vs. 63%, p = 0,011), neurological presentation (more asymptomatic: 72% vs. 62%, p = 0,001) and shunt necessity (33% vs. 14%, p < 0,001). In 32 patients 17 TIAs and 15 strokes were observed. In 3 patients a myocardial infarction occurred. Death occurred in one patient following a stroke and in another patient following myocardial infarction, leading to a combined complication rate of 2,9% (35/1220). In the multivariate analysis only previous neurological symptomatology (OR 2,85, 95% CI 1,38-5,91) and intraoperative shunting (OR 5,57, 95% CI 2,69-11,55) were identified as independent risk factors for an increased combined complication rate. Conclusions: With the routine use of LA, CEA was not associated with worse outcome in high-risk patients. Considering the data reported in the literature, it does not appear justified to refer high-risk patients principally to carotid angioplasty and stenting (CAS) when LA can be chosen to perform CEA.


Sign in / Sign up

Export Citation Format

Share Document