Characterization of ground motion intensity for the seismic fragility assessment of plan-irregular RC buildings

Structures ◽  
2020 ◽  
Vol 27 ◽  
pp. 1763-1776
Author(s):  
Rohan Bhasker ◽  
Arun Menon
Author(s):  
Yusuke Maida ◽  
Tomofusa Akita ◽  
Nobuyuki Izumi

This report presents studies on the seismic response of high-rise RC buildings in Japan. Data concerning the seismic response of approximately 600 high-rise RC buildings constructed from 1972 to 2015 were collected. Seismic response characteristics were analyzed by focusing on differences in seismic resistant structures, seismic response control structures, and seismic isolation structures. The results indicated that the maximum story drift ratio response under the level 1 study seismic ground motion (R) and the level 2 study seismic ground motion (R) criteria is smaller for seismic isolation structures than that of the seismic resistant structure and seismic response control structures. In addition, focusing on the R-R relationship, the correlation is low in the seismic resistant and seismic response control structures, but is almost linear in the seismic isolation structure. This is because the seismic isolation structure is designed such that the superstructure does not become plastic even with level 2 seismic ground motion.


Author(s):  
Erkan Akpinar ◽  
Seckin Ersin

Strengthening of non-ductile public buildings is a never-ending issue. Selection of the suitable strengthening method and appropriate analysis type for the assessment of pre- and the post-intervention performances are still open to question. The displacement or drift limitations are crucial as well as demand capacity ratios for determination of such buildings performance under severe ground motion. In this chapter, an investigation of seismic performance focused on displacement criterion of strengthened non-ductile public RC buildings in Turkey is presented. Both the nonlinear static and response history analysis were conducted. Friction dampers which are fairly modern technique and conventional RC wall implementation method were introduced to as-is building. For the simplicity and the easy of the process, 2D frame selected for investigation. Comparison of the aforementioned techniques for non-ductile public RC buildings and performances particularly by means of displacement obtained using different methods for those investigated schemes are carried out and presented in the chapter.


2019 ◽  
pp. 1073-1089
Author(s):  
Erkan Akpinar ◽  
Seckin Ersin

Strengthening of non-ductile public buildings is a never-ending issue. Selection of the suitable strengthening method and appropriate analysis type for the assessment of pre- and the post-intervention performances are still open to question. The displacement or drift limitations are crucial as well as demand capacity ratios for determination of such buildings performance under severe ground motion. In this chapter, an investigation of seismic performance focused on displacement criterion of strengthened non-ductile public RC buildings in Turkey is presented. Both the nonlinear static and response history analysis were conducted. Friction dampers which are fairly modern technique and conventional RC wall implementation method were introduced to as-is building. For the simplicity and the easy of the process, 2D frame selected for investigation. Comparison of the aforementioned techniques for non-ductile public RC buildings and performances particularly by means of displacement obtained using different methods for those investigated schemes are carried out and presented in the chapter.


Sign in / Sign up

Export Citation Format

Share Document