Absence of lesional features on reflectance confocal microscopy: Quality control steps to avoid false-negative results

2019 ◽  
Vol 81 (3) ◽  
pp. e71-e73 ◽  
Author(s):  
Melissa Gill ◽  
Jane M. Grant-Kels ◽  
Christi Alessi Fox
Polymers ◽  
2021 ◽  
Vol 13 (3) ◽  
pp. 340
Author(s):  
Elisa Chiodi ◽  
Francesco Damin ◽  
Laura Sola ◽  
Lucia Ferraro ◽  
Dario Brambilla ◽  
...  

The manufacture of a very high-quality microarray support is essential for the adoption of this assay format in clinical routine. In fact, poorly surface-bound probes can affect the diagnostic sensitivity or, in worst cases, lead to false negative results. Here we report on a reliable and easy quality control method for the evaluation of spotted probe properties in a microarray test, based on the Interferometric Reflectance Imaging Sensor (IRIS) system, a high-resolution label free technique able to evaluate the variation of the mass bound to a surface. In particular, we demonstrated that the IRIS analysis of microarray chips immediately after probe immobilization can detect the absence of probes, which recognizably causes a lack of signal when performing a test, with clinical relevance, using fluorescence detection. Moreover, the use of the IRIS technique allowed also to determine the optimal concentration of the probe, that has to be immobilized on the surface, to maximize the target recognition, thus the signal, but to avoid crowding effects. Finally, through this preliminary quality inspection it is possible to highlight differences in the immobilization chemistries. In particular, we have compared NHS ester versus click chemistry reactions using two different surface coatings, demonstrating that, in the diagnostic case used as an example (colorectal cancer) a higher probe density does not reflect a higher binding signal, probably because of a crowding effect.


2020 ◽  
Vol 58 (8) ◽  
pp. 1372-1380 ◽  
Author(s):  
Wayne J. Dimech ◽  
Giuseppe A. Vincini ◽  
Liza M. Cabuang ◽  
Megan Wieringa

AbstractBackgroundLaboratories use quality control (QC) testing to monitor the extent of normal variation. Assay lot number changes contribute the greatest amount of variation in infectious disease serology testing. An unexpected change in six lots of an anti-HCV assay allowed the determination of the effect these lot changes made to the assay’s clinical sensitivity.MethodsTwo sets of seroconversion samples comprising of 44 individual samples and 9 external quality assessment scheme (EQAS) samples, all positive to anti-HCV, were tested in affected and unaffected assay lots, and the difference in the quantitative and qualitative results of the samples was analyzed.ResultsOf 44 low-positive seroconversion samples tested in affected and unaffected assay lots, only three samples had results reported below the assay cutoff when tested on two of the six affected assay lot. A further sample had results below the cutoff for only one affected lot. None of the EQAS samples reported false-negative results. Samples having a signal to cutoff value of less than 6.0 generally had lower results in the affected lots compared with the unaffected lots.ConclusionsUnexpected changes in QC reactivity related to variation, in particular assay lot changes, may affect patient results. This study demonstrated that QConnect Limits facilitated the detection of an unexpectedly large variation in QC test results, allowed for the identification of the root cause of the change, and showed that the risk associated with the change was low but credible. The use of evidence-based QC program is essential to detect changes in test systems.


1980 ◽  
Vol 14 (2) ◽  
pp. 173-177 ◽  
Author(s):  
Michael F. W. Festing ◽  
Peter Totman

Strain-specific polyvalent anoantisera may be obtained by injecting lymphocytes pooled from several different strains into an inbred recipient. 6 sera of this type were produced in rats and 23 in mice. A dye-exclusion microcytotoxic test was used to evaluate the strain specificity of such sera. A total of 663 out of 713 (93·0%) of the tests conformed with expectation, but there were 48 (6·7%) false negative results in which the test failed to detect non-authentic animals. There were also 2 (0·3%) false positive results, in which authentic animals were shown as non-authentic. These were attributed to technical errors. Most false negative results occurred when serum and test cell suspensions matched at the major histocompatibility complex. It was concluded that the use of strain-specific polyvalent immune sera, coupled with a simple immunological test such as the microcytotoxic test, offers a sensitive and quick new method for routine genetic quality control.


1974 ◽  
Vol 31 (02) ◽  
pp. 273-278
Author(s):  
Kenneth K Wu ◽  
John C Hoak ◽  
Robert W Barnes ◽  
Stuart L Frankel

SummaryIn order to evaluate its daily variability and reliability, impedance phlebography was performed daily or on alternate days on 61 patients with deep vein thrombosis, of whom 47 also had 125I-fibrinogen uptake tests and 22 had radiographic venography. The results showed that impedance phlebography was highly variable and poorly reliable. False positive results were noted in 8 limbs (18%) and false negative results in 3 limbs (7%). Despite its being simple, rapid and noninvasive, its clinical usefulness is doubtful when performed according to the original method.


2020 ◽  
Vol 13 (1) ◽  
pp. 413-414 ◽  
Author(s):  
Mohamed Farouk Allam

Due to the international spread of COVID-19, the difficulty of collecting nasopharyngeal swab specimen from all suspected patients, the costs of RT-PCR and CT, and the false negative results of RT-PCR assay in 41% of COVID-19 patients, a scoring system is needed to classify the suspected patients in order to determine the need for follow-up, home isolation, quarantine or the conduction of further investigations. A scoring system is proposed as a diagnostic tool for suspected patients. It includes Epidemiological Evidence of Exposure, Clinical Symptoms and Signs, and Investigations (if available). This scoring system is simple, could be calculated in a few minutes, and incorporates the main possible data/findings of any patient.


2020 ◽  
Vol 18 ◽  
Author(s):  
Pegah Shakib ◽  
Mohammad Reza Zolfaghari

Background: Conventional laboratory culture-based methods for diagnosis of Streptococcus pneumoniae are time-consuming and yield false negative results. Molecular methods including real-time (RT)-PCR rapid methods and conventional PCR due to higher sensitivity and accuracy have been replaced instead traditional culture assay. The aim of the current study was to evaluate lytA gene for detection of Streptococcus pneumoniae in the cerebrospinal fluid of human patients with meningitis using real-time PCR assay. Material and Methods: In this cross-sectional study, a total of 30 clinical specimens were collected from patients in a period from September to December 2018. In order to evaluate the presence of lytA gene, conventional and real-time PCR methods were used without culture. Results: From 30 sputum samples five (16.66%) isolates were identified as S. pneumoniae by lytA PCR and sequencing. Discussion: In this research, an accurate and rapid real-time PCR method was used, which is based on lytA gene for diagnosis of bacteria so that it can be diagnosed. Based on the sequencing results, the sensitivity for detection of lytA gene was 100% (5/5).


Coronaviruses ◽  
2020 ◽  
Vol 01 ◽  
Author(s):  
Maria Silvia De Feo ◽  
Viviana Frantellizzi ◽  
Giuseppe De Vincentis

Background: We present the case of a 55-year-old woman, admitted to the Infectious Disease Department of Policlinico Umberto I, Rome, in mid-March 2020, with suspicion of COVID-19 infection. Objective: The rRT-PCR was negative and the following CT scan, performed to exclude false-negative results and help diagnosis, was inconclusive. Methods: It was decided to submit the patient to 99mTc-HMPAO-labelled leukocyte scan. Results: This exam led to the diagnosis of infective endocarditis. Conclusion: In the present pandemic scenario, 99mTc-HMPAO-labelled leukocyte scan represents a reliable imaging technique for differential diagnosis with COVID-19 in patients with confusing clinical signs, possible false-negative rRT-PCR results and inconclusive CT scan.


Author(s):  
Hyoung-Jin Moon ◽  
Won Lee ◽  
Ji-Soo Kim ◽  
Eun-Jung Yang ◽  
Hema Sundaram

Abstract Background Aspiration testing before filler injection is controversial. Some believe that aspiration can help prevent inadvertent intravascular injection, while others cite false-negative results and question its value given that the needle position always changes somewhat during injection procedures. Objectives To test the relation of false-negative results to the viscosity of the material within the needle lumen and determine whether a less viscous material within the needle lumen could decrease the incidence of false-negative results. Methods In vitro aspiration tests were performed using 30-G and 27-G needle gauges, two cross-linked hyaluronic acid fillers, normal saline bags pressurized at 140 and 10 mmHg to mimic human arterial and venous pressures, and three needle lumen conditions (normal saline, air, and filler). Testing was repeated three times under each study condition (72 tests in total). For in vivo correlation, aspiration tests were performed on femoral arteries and central auricular veins in three rabbits (4–5 aspirations per site, 48 tests in total). Results In vitro and in vivo testing using 30-G needles containing filler both showed false-negative results on aspiration testing. In vitro and in vivo testing using needles containing saline or air showed positive findings. Conclusions False-negative results from aspiration testing may be reduced by pre-filling the needle lumen with saline rather than a filler. The pressurized system may help overcome challenges of animal models with intravascular pressures significantly different from those of humans. The adaptability of this system to mimic various vessel pressures may facilitate physiologically relevant studies of vascular complications.


Sign in / Sign up

Export Citation Format

Share Document