Importance of the PMMA viscoelastic rheology on the reduction of the leakage risk during osteoporotic bone augmentation: A numerical leakage model through a porous media

Author(s):  
Salem Alenezi ◽  
Saeed Jerban ◽  
Saïd Elkoun
Coatings ◽  
2020 ◽  
Vol 11 (1) ◽  
pp. 20
Author(s):  
Xingya Ni ◽  
Chenbo Ma ◽  
Jianjun Sun ◽  
Yuyan Zhang ◽  
Qiuping Yu

A theoretical model for calculating the leakage rate of contact mechanical seals based on the fractal theory of the porous media, which can consider the real seal contact interface and objectively reflect the flow of the interfacial fluid from a microscopic perspective, is established. In order to obtain the microstructural parameters of the porous media included in the leakage model, such as the fractal dimension and the maximum pore diameter, the real seal contact interface obtained from experiments is reconstructed, a contact model between the dynamic and static rings is proposed, and then the calculation methods for the interface characteristic parameters are provided. Numerical simulation results show that as the contact pressure increases from 0.05 to 0.5 MPa, the interface porosity and the maximum pore diameter decreases gradually. Furthermore, the fractal dimension of the pore area increases and the leakage rate of the interface decreases from 0.48 to 0.33 mL/h. The proposed method provides a novel way of calculating the leakage rate of contact mechanical seals.


Coatings ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 1338
Author(s):  
Guangyao Bei ◽  
Chenbo Ma ◽  
Jianjun Sun ◽  
Xingya Ni ◽  
Yafei Ma

The fluid leakage channel found in contact mechanical seals belongs to the microchannel category. Thus, upon further inspection, the influence of surface wettability and other factors neglected in previous studies becomes obvious. The porous leakage model of contact mechanical seals considering the surface wettability presented in this paper was based on the Cassie model and slip theory. The variations of the microchannel slip length and the velocity under various wettability conditions were studied and the relationship between the slip length and the apparent contact angle was established. Moreover, using porous media theory, the theoretical model of the leakage rate in contact mechanical seals considers the surface wettability depending on various parameters. The observed parameters included the surface contact angle, sealing medium pressure, viscosity coefficient, fractal dimension, and maximum pore diameter. The simulation results obtained using the proposed model have shown that the leakage rate increases with the increase of the apparent contact angle. Particularly when the contact pressure is small, the influence of the surface wettability is more significant. Furthermore, the leakage rate results obtained via the proposed model were compared to those of existing models. The comparison confirmed that the proposed model is applicable and that the necessity of considering wettability significantly affects the leakage rate calculation accuracy. The proposed model lays a foundation for further improving the calculation accuracy, making it easier for both the researchers and practitioners to suppress the leakage in contact mechanical seals.


2020 ◽  
Vol 188 ◽  
pp. 104227 ◽  
Author(s):  
Chuanjun Liao ◽  
Haipeng Chen ◽  
Haoran Lu ◽  
Ruitao Dong ◽  
Hailiang Sun ◽  
...  

Author(s):  
Amirhossein Farvardin ◽  
Mehran Armand

Abstract A potential effective treatment for prevention of osteoporotic hip fractures is augmentation of the mechanical properties of the femur by injecting it with Polymethyl-Methacrylate (PMMA). We have previously developed a preoperative planning workstation to optimize the pattern of cement injection. In this planning paradigm, injections occur on a straight line limiting the overall match between the optimal and injected volumes of the cement. In addition, new advancements in drilling techniques has made it possible to plan and drill the bone based on a curved trajectory. In this study, we introduced a methodology to find the optimal drill path for PMMA injection. With the aid of Finite Element (FE) and hydrodynamic simulations, the effectiveness of the proposed approach was evaluated. Results showed that with an average injection of 7.2 ml, the proposed method can increase the yield load of the femur by 69%. Future works involve experimental validation of this method in cadaveric studies.


PLoS ONE ◽  
2013 ◽  
Vol 8 (6) ◽  
pp. e67958 ◽  
Author(s):  
Ehsan Basafa ◽  
Ryan J. Murphy ◽  
Michael D. Kutzer ◽  
Yoshito Otake ◽  
Mehran Armand

Sign in / Sign up

Export Citation Format

Share Document