scholarly journals Experimental study and operation optimization of a parallel-loop heat pump for exhaust air recovery in residential buildings

2021 ◽  
pp. 103468
Author(s):  
Xiaoya Jia ◽  
Guoyuan Ma ◽  
Feng Zhou ◽  
Shuailing Liu ◽  
Guoqiang Wu ◽  
...  
Membranes ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 725
Author(s):  
Ahmadou Tidiane Diaby ◽  
Paul Byrne ◽  
Patrick Loulergue ◽  
Ousmane Sow ◽  
Thierry Maré

Heat pump systems can simultaneously produce cooling energy for space cooling in hotels, office and residential buildings and heat for desalination using membrane distillation (MD). The MD technique uses a heat input at a temperature compatible with the levels of heat pump condensers (<60 °C). A heat pump prototype coupled with an air-gap membrane distillation unit was constructed and tested. This paper presents the experimental study on a lab-scale prototype and details the two operating modes “continuous” and “controlled” simulating an air conditioning system and a food storage, respectively. The experimental results enable to analyze the performance of the prototype and the physical phenomena involved. Finally, the study shows that this system could be a promising solution to help supplying freshwater to people in hot regions of the world.


Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1321
Author(s):  
Yu-Jin Hwang ◽  
Jae-Weon Jeong

The objective of this research is to establish an appropriate operating strategy for a radiant floor heating system that additionally has an air source heat pump for providing convective air heating separately, leading to heating energy saving and thermal comfort in residential buildings. To determine the appropriate optimal operating ratio of each system taking charge of combined heating systems, the energy consumption of the entire system was drawn, and the adaptive floor surface temperature was reviewed based on international standards and literature on thermal comfort. For processing heating loads with radiant floor heating and air source heating systems, the heating capacity of radiant floor heating by 1 °C variation in floor temperature was calculated, and the remaining heating load was handled by the heating capacity of the convective air heating heat pump. Consequently, when the floor temperature was 25 °C, all heating loads were removed by radiant floor heating only. When handling all heating loads with the heat pump, 59.2% less energy was used compared with radiant floor heating only. Considering the local discomfort of the soles of the feet, the floor temperature is expected to be suitable at 22–23 °C, and 31.5–37.6% energy saving compared with those of radiant floor heating alone were confirmed.


2021 ◽  
Vol 11 (11) ◽  
pp. 5218
Author(s):  
Matteo Zatti ◽  
Matteo Moncecchi ◽  
Marco Gabba ◽  
Alberto Chiesa ◽  
Filippo Bovera ◽  
...  

Energy communities (EC) are expected to have a pivotal role to reach European decarbonization targets. One of the key aspects is the regulatory framework adopted by each Member State to properly manage such new customers’ aggregation. The paper firstly provides an updated overview of the EC regulation, focusing on the current Italian legislation. Next, a novel methodology for the design and management of energy community initiatives is proposed. The procedure firstly solves a design and operation optimization problem to calculate the best size of energy assets (boiler, heat pump, photovoltaic, thermal storage) to be installed. Second, a Shapley value-based approach is exploited to distribute a part of the community’s incomes to members, based on their contribution to the overall welfare. Results demonstrate that the adopted methodology is effective in ensuring a proper cash flow for the community, while pushing its members towards energy efficient behaviors.


2021 ◽  
pp. 111204
Author(s):  
Hannah Krützfeldt ◽  
Christian Vering ◽  
Philipp Mehrfeld ◽  
Dirk Müller

2013 ◽  
Vol 732-733 ◽  
pp. 564-570 ◽  
Author(s):  
Ying Ning Hu ◽  
Ya Zhao Liu ◽  
Jun Lin ◽  
Yan Wang

A ground source heat pump system of combined office and residential buildings in hot summer and warm winter region is introduced. The system performance is studied through the experiment, and the performance of underground heat balance is analyzed by TRNSYS. The results show the superiority and applicability of the ground source heat pump system.


2017 ◽  
Vol 110 ◽  
pp. 835-843 ◽  
Author(s):  
Minglu Qu ◽  
Yanan Fan ◽  
Jianbo Chen ◽  
Tianrui Li ◽  
Zhao Li ◽  
...  

2013 ◽  
Vol 61 ◽  
pp. 39-50 ◽  
Author(s):  
Amir Rezaei-Bazkiaei ◽  
Ehsan Dehghan-Niri ◽  
Ebrahim M. Kolahdouz ◽  
A. Scott Weber ◽  
Gary F. Dargush

Sign in / Sign up

Export Citation Format

Share Document