A case study in the field of building sustainability energy: Performance enhancement of solar air heater equipped with PCM: A trade-off between energy consumption and absorbed energy

2021 ◽  
pp. 103903
Author(s):  
Nidal H. Abu-Hamdeh ◽  
Radi A. Alsulami ◽  
Randa I. Hatamleh
2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Thanh Truc Le Gia ◽  
Hoang-Anh Dang ◽  
Van-Binh Dinh ◽  
Minh Quan Tong ◽  
Trung Kien Nguyen ◽  
...  

PurposeIn many countries, innovation in building design for improving energy performance, reducing CO2 emissions and minimizing life cycle cost has received much attention for sustainable development. This paper investigates the importance of optimization tools for enhancing the design performance in the early stages of Vietnam's cooling-dominated buildings in hot and humid climates using an integrated building design approach.Design/methodology/approachThe methodology of this study exploits the non-dominated sorting genetic algorithm (NSGA-II) optimization algorithm coupled with building simulation to research a trade-off between the optimization of investment cost and energy consumption. Our approach focuses on the whole optimization problem of thermal envelope, glazing and energy systems from preliminary design phases. The methodology is then tested for a case study of a non-residential building located in Hanoi.FindingsThe results show a considerable improvement in design performance by our method compared to current building design. The optimal solutions present the trade-off between energy consumption and capital cost in the form of a Pareto front. This helps architects, engineers and investors make important decisions in the early design stages with a large view of impacts of all factors on energy performance and cost.Originality/valueThis is one of the original research to study integrated building design applying the simulation-based genetic optimization algorithm for cooling-dominated buildings in Vietnam. The case study in this article is for a non-residential building in the north of Vietnam but the methodology can also be applied to residential buildings and other regions.


2020 ◽  
Vol 147 ◽  
pp. 2345-2357 ◽  
Author(s):  
C. Sivakandhan ◽  
T.V. Arjunan ◽  
M.M. Matheswaran

Solar Energy ◽  
2018 ◽  
Vol 174 ◽  
pp. 556-569 ◽  
Author(s):  
Ajeet Pratap Singh ◽  
O.P. Singh

2020 ◽  
Vol 10 (3) ◽  
pp. 893 ◽  
Author(s):  
Laura Cirrincione ◽  
Maria La Gennusa ◽  
Giorgia Peri ◽  
Gianfranco Rizzo ◽  
Gianluca Scaccianoce ◽  
...  

In the line of pursuing better energy efficiency in human activities that would result in a more sustainable utilization of resources, the building sector plays a relevant role, being responsible for almost 40% of both energy consumption and the release of pollutant substances in the atmosphere. For this purpose, techniques aimed at improving the energy performances of buildings’ envelopes are of paramount importance. Among them, green roofs are becoming increasingly popular due to their capability of reducing the (electric) energy needs for (summer) climatization of buildings, hence also positively affecting the indoor comfort levels for the occupants. Clearly, reliable tools for the modelling of these envelope components are needed, requiring the availability of suitable field data. Starting with the results of a case study designed to estimate how the adoption of green roofs on a Sicilian building could positively affect its energy performance, this paper shows the impact of this technology on indoor comfort and energy consumption, as well as on the reduction of direct and indirect CO2 emissions related to the climatization of the building. Specifically, the ceiling surface temperatures of some rooms located underneath six different types of green roofs were monitored. Subsequently, the obtained data were used as input for one of the most widely used simulation models, i.e., EnergyPlus, to evaluate the indoor comfort levels and the achievable energy demand savings of the building involved. From these field analyses, green roofs were shown to contribute to the mitigation of the indoor air temperatures, thus producing an improvement of the comfort conditions, especially in summer conditions, despite some worsening during transition periods seeming to arise.


2019 ◽  
Vol 13 (3) ◽  
pp. 5562-5587 ◽  
Author(s):  
M. S. Manjunath ◽  
R. Venkatesh ◽  
N. Madhwesh

The aim of this study is to determine the effect of U-shaped rib turbulator on the flow and heat transfer characteristics of flat plate solar air heater using two dimensional CFD analysis. The analysis is carried out using the CFD software tool ANSYS Fluent for the flow Reynolds number ranging from 9000 to 21,000.The relative pitch(P/e) of the U-shaped rib is varied as 5, 10, 25 and 40 for a fixed relative rib height of 0.0421. It is shown that the U-shaped rib augments the Nusselt number by about 1.76 times while the friction factor increased by about 1.95 times with reference to smooth duct for a relative pitch of 10 and 5 respectively. The maximum thermal enhancement factor is obtained as 1.5 for the configuration of P/e=25. A comparative analysis of U-shaped rib with circular rib reveals that the U-shaped rib turbulator is found to be more effective in providing heat transfer enhancement and has about 15% higher thermal enhancement factor as compared to circular turbulator.


Buildings ◽  
2019 ◽  
Vol 9 (9) ◽  
pp. 190
Author(s):  
Irina Susorova ◽  
Brent Stephens ◽  
Benjamin Skelton

A common envelope performance problem in buildings is thermal bridging through balcony slab connections, which can be improved with the use of commercially available thermal break products. Several prior studies have used simulation-based and/or hot box test apparatus approaches to quantify the likely effect of balcony thermal breaks on effective thermal resistance of building enclosures. However, in-situ measurements of thermal performance in real buildings remain limited to date. This study uses a combination of field measurements and models to investigate the effects of installing balcony thermal breaks on the interior surface temperatures, effective thermal resistance, and annual building energy consumption. For the field experiment, yearlong measurements were conducted on the 13th floor of a 14-story multi-family building in Chicago, IL, in which thermocouple sensors were embedded into eight balconies and their adjacent interior floor slabs just before concrete was poured to complete the construction. The eight balconies included four control balconies without thermal breaks and four thermally-broken balconies with a commercially available thermal break product installed. The experimental data were then combined with 2-D heat transfer modeling and whole building energy simulations to investigate the impacts of the thermal break product installation on the envelope thermal resistance and overall energy use in the case study building as well as in several more generic building designs with simpler geometries. The results demonstrate that although the balcony thermal breaks helped regulate interior slab temperatures and improved the effective thermal resistance of the curtain wall enclosure assembly by an estimated ~14% in the case study building, the predicted effect on annual energy consumption in all modeled building types was small (i.e., less than 2%). The results also highlight the importance of paying careful attention to envelope design details when using thermal break products and considering the use of thermal break products in combination with other energy efficiency strategies to achieve high performance enclosures.


Sign in / Sign up

Export Citation Format

Share Document