thermal enhancement factor
Recently Published Documents


TOTAL DOCUMENTS

16
(FIVE YEARS 12)

H-INDEX

3
(FIVE YEARS 1)

Entropy ◽  
2021 ◽  
Vol 23 (11) ◽  
pp. 1482
Author(s):  
Yuting Jia ◽  
Jianwei Huang ◽  
Jingtao Wang ◽  
Hongwei Li

A novel microchannel heat sink with oval-shaped micro pin fins (MOPF) is proposed and the characteristics of fluid flow and heat transfer are studied numerically for Reynolds number (Re) ranging from 157 to 668. In order to study the influence of geometry on flow and heat transfer characteristics, three non-dimensional variables are defined, such as the fin axial length ratio (α), width ratio (β), and height ratio (γ). The thermal enhancement factor (η) is adopted as an evaluation criterion to evaluate the best comprehensive thermal-hydraulic performance of MOPF. Results indicate that the oval-shaped pin fins in the microchannel can effectively prevent the rise of heat surface temperature along the flow direction, which improves the temperature distribution uniformity. In addition, results show that for the studied Reynolds number range and microchannel geometries in this paper, the thermal enhancement factor η increases firstly and then decreases with the increase of α and β. In addition, except for Re = 157, η decreases first and then increases with the increase of the fin height ratio γ. The thermal enhancement factor for MOPF with α = 4, β = 0.3, and γ = 0.5 achieves 1.56 at Re = 668. The results can provide a theoretical basis for the design of a microchannel heat exchanger.


Energies ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6764
Author(s):  
Sadiq Ali ◽  
Faraz Ahmad ◽  
Kareem Akhtar ◽  
Numan Habib ◽  
Muhammad Aamir ◽  
...  

The present study investigates the thermo-hydraulic characteristics of a microchannel sink with novel trefoil Shaped ribs. The motivation for this form of rib shape is taken from the design of lung alveoli that exchange oxygen and carbon dioxide. This study has been conducted numerically by using a code from the commercially available Fluent software. The trefoil shaped ribs were mounted on the centerline of different walls of the microchannel in three different configurations. These consisted of base wall trefoil ribs (MC-BWTR), sidewall trefoil ribs (MC-SWTR), all wall trefoil ribs (MC-AWTR) and smooth channel (MC-SC) having no ribs on its wall. The streamline distance between the ribs was kept constant at 0.4 mm, and the results were compared by using pressure drop (Δp), Nusselt number (Nu), thermal resistance (Rth) and thermal enhancement factor (η). The results indicated that the addition of trefoil ribs to any wall improved heat transfer characteristics at the expense of an increase in the friction factor. The trends of the pressure drop and heat transfer coefficient were the same, which indicated higher values for MC-AWTR followed by MC-SWTR and a lower value for MC-BWTR. In order to compare the thermal and hydraulic performance of all the configurations simultaneously, the overall performance was quantified in terms of the thermal enhancement factor, which was higher than one in each case, except for MC-AWTR, in 100 < Re < 200 regimes. The thermal enhancement factor in the ribbed channel was the highest for MC-SWTR followed by MC-BWTR, and it was the lowest for MC-AWTR. Moreover, the thermal enhancement factor increases with the Reynolds number (Re) for each case. This confirms that the increment in the Nusselt number with velocity is more significant than the pressure drop. The highest thermal enhancement factor of 1.6 was attained for MC-SWTR at Re = 1000, and the lowest value of 0.87 was achieved for MC-AWTR at Re = 100.


Fluids ◽  
2021 ◽  
Vol 6 (10) ◽  
pp. 344
Author(s):  
Syaiful ◽  
Tri Wahyuni ◽  
Bambang Yunianto ◽  
Nazaruddin Sinaga

Improving heat transfer from surface to airflow is a current research concern for enhancing energy efficiency. The use of vortex generators for improving heat transfer from the surface to the airflow is very effective. Therefore, this study focuses on applying flat and concave vortex generators with and without holes in order to improve heat transfer. In this study, the number of pairs of vortex generators was varied from one to three pairs at a certain angle of attack for various forms of vortex generators. The airflow velocity through the duct was varied in the range of 0.4 to 2.0 m/s at 0.2 m/s intervals. From the investigation results, we observed that the highest thermal performance was found with the use of concave delta winglets without holes for various pairs of vortex generators in terms of the overall Reynolds number. The highest thermal enhancement factor was found to be around 1.42 at a Reynolds number of approximately 9000. From this study, it was also shown that the lowest cost–benefit ratio was about 1.75 at a Reynolds number of approximately 3500 for three pairs of vortex generators.


Author(s):  
Dr. Dolfred Vijay Fernandes ◽  
Manjunath M.S.

Two-dimensional numerical analysis is conducted to determine the influence of upstream surface modifications of a novel clerestory shaped rib turbulator on thermal performance augmentation. The upstream surface of the rib is divided into two parts where the upper rib surface is always normal to the incoming flow and the lower rib surface, which is inclined to the flow. The elevation of the vertical surface is varied using non-dimensional approach length (h/e=0, 0.25, 0.5 and 0.75), and the inclination of the lower surface is varied using the rib angle (θ=15°, 45° and 90°). The relative roughness height and pitch of rib is fixed as 0.0421 and 12.5, respectively. RNG k-ϵ turbulence model is used in the analysis, and Reynolds number is varied from 8000-20000. The results reveal that the combined effect of flow impingement and the suppression of formation of recirculation zone leads to increased heat transfer. Lower values of non-dimensional approach length and rib angle provides a higher thermal enhancement factor. The highest increase in Nusselt number is found to be about 1.82 times that of the smooth duct at Re=8000 for h/e=0.25 and rib angle of 15°. The maximum thermal enhancement factor is found to have a range of 1.6-1.45 for an approach length of 0.25 and a rib angle of 15°.


2021 ◽  
pp. 172-186
Author(s):  
Shamoon Jamshed

Optimization in engineering is a significant tool for selecting the best fit when several design variables are present. It helps in determining the optimum through a combination of a set of design variables with objective functions subject to certain constraints. In the design of heat exchangers too, where tremendous research is going on to optimize its effectiveness, certain efforts are being done to improve the quality of the inner tube, shell, or plate design. In this respect, surface enhancement has been actively researched in recent decades. This sort of augmentation is usually dominant on the tube side. It has been seen that the study is greatly conducted in the past experimentally, but numerical studies are limited to determine friction factor or Nusselt number. Only a few discussed an important factor called entropy generation minimization. In this paper, with the optimization in view, the design is based on multiple disciplines. That is, first a numerical study is performed on the helically grooved tubes to examine the thermal enhancement factor. Numerical results are initially validated with published experimental results. The optimized tube is then selected based on the D-optimal design for the thermal enhancement factor and finally, the entropy minimization study concerning the Reynolds number is conducted on the optimized tube. It is observed that the tube with the greatest number of grooves, the maximum depth, and the least pitch performs the best. However, the optimum Reynolds number is at the point where the tube has the least entropy generated as compared to the smooth tube.


2021 ◽  
pp. 183-183
Author(s):  
Sendogan Karagoz ◽  
Semih Erzincanli ◽  
Orhan Yildirim ◽  
Ilker Firat ◽  
Mehmet Kaya ◽  
...  

This experimental study deals with the heat transfer and friction effects of sinusoidal part turbulators for single-phase flows occurring in a circular shaped pipe. Turbulators with three different radius values are placed in the pipe to make the flow turbulent. In this way, changes in Nusselt number and friction coefficient are examined. As a result of the experiments made with Reynolds numbers in the range of 6614-20710, the increase rates of the Nusselt numbers of turbulators with 20 mm, 110 mm and 220 mm radius compared to the empty pipe were obtained as 153.49%, 85.36%, and 52.09%, respectively. As a result of the decrease in the radius, there was an increase in the Nusselt number and the friction factor. Parallel to the Nusselt number, the highest friction factor was obtained in the smallest radius turbulator. It was found that the thermal enhancement factors of 110 mm and 220 mm radius turbulators increased by 179.54% and 132.95%, respectively, compared to the 20 mm radius turbulator. Similarly, it was determined that the thermal enhancement factor of the 110 mm radius turbulator increased by 20% compared to the 220 mm radius turbulator.


2020 ◽  
Vol 14 (3) ◽  
pp. 7282-7295
Author(s):  
R. Venkatesh ◽  
Nitesh Kumar ◽  
N. Madhwesh ◽  
Manjunath M.S.

This paper presents the effect of deflector ribs on the thermal performance of flat plate solar air heater using Computational Fluid Dynamics (CFD) methodology. The analysis is carried out using two-dimensional computational domain for the Reynolds number range of 6000-18000. RNG k-є turbulence model is used to capture the turbulence characteristics of the flow. The deflector rib has a cross-section of isosceles triangle and is placed transversely with respect to the flow. The distance between consecutive ribs is varied as 40mm, 80mm, 160mm and 320mm while the air gap height is varied as 2mm, 3mm, 5mm and 10mm. The numerical model is validated against the well-known correlation of Dittus-Boelter for smooth duct. The simulation results reveal that the presence of deflector ribs provide augmented heat transfer through flow acceleration and enhanced turbulence levels. With reference to smooth duct, the maximum achieved heat transfer improvement is about 1.39 times for the inter-rib distance of 40mm and an air gap height of 3mm while the maximum fiction factor achieved was about 3.82 times for pitch value of 40mm and air gap height of 3mm. The highest thermal enhancement factor is achieved for the pitch value of 320mm and an air gap height of 3mm at Re=6000. The air gap height value of 10mm exhibits thermal enhancement factor values lesser than 1.0 and hence is not recommended for use as heat transfer enhancement device for the entire Reynolds number range used in the analysis. The pitch value of 320 mm exhibits thermal enhancement factor greater than 1.0 for almost all the Reynolds number range used in the analysis and varies between 0.93 and 1.07.


Solar Energy ◽  
2020 ◽  
Vol 198 ◽  
pp. 295-310 ◽  
Author(s):  
A. Leander Antony ◽  
Shreyas P. Shetty ◽  
N. Madhwesh ◽  
N. Yagnesh Sharma ◽  
K. Vasudeva Karanth

2020 ◽  
Vol 2020 ◽  
pp. 1-22
Author(s):  
Amnart Boonloi ◽  
Withada Jedsadaratanachai

Thermal performance development, heat transfer structure, and flow behavior in the heat exchanger square duct equipped with a 45° inclined square ring are investigated numerically. The effects of flow blockage ratios and spacing ratios for the inclined square ring on fluid flow and heat transfer are considered. The Reynolds number (Re = 100–2000, laminar regime) based on the hydraulic diameter of the square duct is selected for the present work. The numerical domain of the square duct inserted with the 45° inclined square ring is solved with the finite volume method. The SIMPLE algorithm is picked for the numerical investigation. The heat transfer characteristics and flow topologies in the square duct inserted with the inclined square ring are plotted in the numerical report. The heat transfer rate, pressure loss, and efficiency for the square duct placed with the inclined square ring are presented in forms of Nusselt number, friction factor, and thermal enhancement factor, respectively. As the numerical results, it is detected that the heat transfer rate of the heat exchanger square duct inserted with the inclined square ring is around 1.00–10.05 times over the smooth duct with no inclined square ring. Additionally, the maximum thermal enhancement factor for the heat exchanger square duct inserted with the inclined square ring is around 2.84.