Fast and efficient zirconia-based reversed phase chromatography for selective determination of triptans in rat plasma

2017 ◽  
Vol 143 ◽  
pp. 241-251 ◽  
Author(s):  
Sameh Ahmed ◽  
Noha N. Atia
Bioanalysis ◽  
2020 ◽  
Vol 12 (9) ◽  
pp. 597-613
Author(s):  
Aml A Emam ◽  
Neven M Habib ◽  
Hamada M Mahmoud ◽  
Nada S Abdelwhab ◽  
Maha M Abdelrahman

Background: Olanzapine (OLZ) is one of most recommended drugs for the treatment of schizophrenia while metformin (MET) is the most commonly used hypoglycemic agent. Aim: Development and validation of two green, sensitive and accurate chromatographic methods for the simultaneous determination of OLZ along with the co-prescribed, MET. Materials & methods: TLC-densitometric method with a developing system consisting of methylene chloride:methanol:ethyl acetate:triethylamine (4:4:5:0.1, by volume) and a reversed-phase (RP)-HPLC method where the chromatographic separation was performed using ethanol:water mixture (50: 50, v/v) as a mobile phase. Results: TLC-densitometric method had linearity over concentration ranges of 160–4000 ng/band for OLZ and 150–4500 ng/band for MET, while RP-HPLC method was linear and validated over concentration range of 300–20000 ng/ml for OLZ and MET. Conclusion: Pharmacokinetic study was successfully performed and suggested the possibility of co-administration of MET with OLZ and their further formulation in one pharmaceutical preparation to enhance patient’s compliance.


2020 ◽  
Vol 35 (3) ◽  
pp. 560-566
Author(s):  
Jakub Karasiński ◽  
Cuc Thi Nguyen-Marcińczyk ◽  
Marcin Wojciechowski ◽  
Ewa Bulska ◽  
Ludwik Halicz

A robust and sensitive method for the precise isotopic analysis of 53Cr/50Cr during Cr(iii) oxidation by coupling ion pair reversed-phase chromatography and Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICPMS) is presented.


2001 ◽  
Vol 84 (3) ◽  
pp. 634-639 ◽  
Author(s):  
John J Johnston ◽  
Margaret J Goodall ◽  
Jerome C Hurley ◽  
Christi A Yoder ◽  
Lowell A Miller

Abstract Liquid chromatographic (LC) methods were developed for quantitating the potential avian contraceptive DiazaCon in quail feed and serum. DiazaCon was extracted from ground quail feed with basic n-butyl chloride. The n-butyl chloride extract was evaporated to dryness. The DiazaCon residues were dissolved in an aqueous methanolic ion pairing solution and quantitated by LC at 206 nm. Avian sera was combined with an equal volume of a pH 4 aqueous solution of ion pairing reagent and filtered to remove interfering proteins. DiazaCon was quantitated by LC. Mean recoveries for 500 and 2000 ppm fortified feed were 89.1 and 91.0%, respectively. The mean recovery for sera fortified at 5 levels ranging from 35 to 2000 ppm was 84.9%. Method limits of detection were approximately 14 and 13 ppm for feed and sera, respectively.


Sign in / Sign up

Export Citation Format

Share Document