Uncertainties in prediction of local peak wind pressures on mid- and high-rise buildings by considering gumbel distributed pressure coefficients

2020 ◽  
Vol 206 ◽  
pp. 104364
Author(s):  
Si Han Li ◽  
John Kilpatrick ◽  
Matthew T.L. Browne ◽  
Will Yakymyk ◽  
Maryam Refan
2021 ◽  
Vol 11 (15) ◽  
pp. 7121
Author(s):  
Shouke Li ◽  
Feipeng Xiao ◽  
Yunfeng Zou ◽  
Shouying Li ◽  
Shucheng Yang ◽  
...  

Wind tunnel tests are carried out for the Commonwealth Advisory Aeronautical Research Council (CAARC) high-rise building with a scale of 1:400 in exposure categories D. The distribution law of extreme pressure coefficients under different conditions is studied. Probability distribution fitting is performed on the measured area-averaged extreme pressure coefficients. The general extreme value (GEV) distribution is preferred for probability distribution fitting of extreme pressure coefficients. From the comparison between the area-averaged coefficients and the value from GB50009-2012, it is indicated that the wind load coefficients from GB50009-2012 may be non-conservative for the CAARC building. The area reduction effect on the extreme wind pressure is smaller than that on the mean wind pressure from the code. The recommended formula of the area reduction factor for the extreme pressure coefficient is proposed in this study. It is found that the mean and the coefficient of variation (COV) for the directionality factors are 0.85 and 0.04, respectively, when the orientation of the building is given. If the uniform distribution is given for the building’s orientation, the mean value of the directionality factors is 0.88, which is close to the directionality factor of 0.90 given in the Chinese specifications.


2020 ◽  
Vol 2020 ◽  
pp. 1-24
Author(s):  
Fu-Bin Chen ◽  
Xiao-Lu Wang ◽  
Yun Zhao ◽  
Yuan-Bo Li ◽  
Qiu-Sheng Li ◽  
...  

High-rise buildings are very sensitive to wind excitations, and wind-induced responses have always been the key factors for structural design. Facade openings have often been used as aerodynamic measures for wind-resistant design of high-rise buildings to meet the requirement of structural safety and comfort. Obvious wind speed amplifications can also be observed inside the openings. Therefore, implementing wind turbines in the openings is of great importance for the utilization of abundant wind energy resources in high-rise buildings and the development of green buildings. Based on numerical simulation and wind tunnel testing, the wind loads and wind speed amplifications on high-rise buildings with openings are investigated in detail. The three-dimensional numerical simulation for wind effects on high-rise building with openings was firstly carried out on FLUENT 15.0 platform by SST k − ε model. The mean wind pressure coefficients and the wind flow characteristics were obtained. The wind speed amplifications at the opening were analyzed, and the distribution law of wind speed in the openings is presented. Meanwhile, a series of wind tunnel tests were conducted to assess the mean and fluctuating wind pressure coefficients in high-rise building models with various opening rates. The variation of wind pressure distribution at typical measuring layers with wind direction was analyzed. Finally, the wind speed amplifications in the openings were studied and verified by the numerical simulation results.


2020 ◽  
Vol 313 ◽  
pp. 00047
Author(s):  
Michal Franek ◽  
Marek Macák ◽  
Oľga Hubová

The wind flow around the elliptical object was investigated experimentally in the BLWT wind tunnel in Bratislava and subsequently solved by computer wind flow simulation. On a high-rise building model, the external wind pressure coefficients were evaluated for different wind directions and then compared with the numerical CFD simulation in ANSYS, where different models of turbulence and mesh types were used. The aim of the article was to evaluate and compare the obtained values and after analysing the results to choose the most suitable model of turbulence and mesh types, which showed the smallest deviations from the experimental values.


2011 ◽  
Vol 94-96 ◽  
pp. 1026-1030
Author(s):  
Yue Ming Luo ◽  
Yue Yin ◽  
Xi Liang Liu

Due to the increasing of wind disaster, structural wind engineering arouses more and more attention recently, with rapid development on spatial structure and continuous innovation of structural style. The main purpose of structural wind engineering is to calculate the wind pressure coefficients of structure. In this paper, the numerical wind tunnel method (NWTM), based on the Computational Fluid Dynamics (CFD), is applied to study wind load. The wind pressure coefficients of reticulated spherical shell with the 4.6m high wall were first determined, using the NWTM. The results are then compared with the wind tunnel test (WTT) and good agreement is found. The feasibility and reliability of NWTM were then verified. As the second example, NWTM is carried out to predict wind-induced pressure on reticulated spherical shell without wall. Further the distribution behavior of wind pressures on this kind of structures is discussed which could provide professionals the reference for the design of structure.


2013 ◽  
Vol 639-640 ◽  
pp. 515-522
Author(s):  
Yong Gui Li ◽  
Q.S. Li

Wind tunnel test of 1:500 rigid model of tall building with atrium was carried out. Based on the experimental results, characteristics of wind pressures on atrium facades and wind loads on the structure were investigated in detail. The results show that the formation of flow separation on the building top plays a critical role in the generation of wind pressures on the atrium facades. Meanwhile, wind pressure coefficient distributions on the atrium facades are found to be relatively uniform. Moreover, the horizontal and vertical correlations of pressure coefficient exhibit high at most locations on atrium facades. With the increasing of the opening ratio, the mean wind pressure coefficients first decreased and then stabilized, and the fluctuating wind pressure coefficients first decreased and then increased. A design guideline for the wind-resistant design of atrium facades was proposed, and the results predicted by the proposed guideline were in good agreement with those from the wind tunnel tests, indicating that the proposed guideline can be used in engineering applications. When the opening ratio is no more than 5.33%, the effect of the facade pressures within the atrium on the wind loads on the structure can be ignored. For such cases, the wind-resistant design for a tall building with atrium can refer to that of a similar shape tall building without atrium.


Sign in / Sign up

Export Citation Format

Share Document