Effect of rib arrangements on the flow pattern and heat transfer in internally ribbed rectangular divergent channels

Author(s):  
K. Sivakumar ◽  
T. Sampath Kumar ◽  
S. Sivasankar ◽  
V. Ranjithkumar ◽  
A. Ponshanmugakumar
Keyword(s):  
Author(s):  
Weilin Qu ◽  
Seok-Mann Yoon ◽  
Issam Mudawar

Knowledge of flow pattern and flow pattern transitions is essential to the development of reliable predictive tools for pressure drop and heat transfer in two-phase micro-channel heat sinks. In the present study, experiments were conducted with adiabatic nitrogen-water two-phase flow in a rectangular micro-channel having a 0.406 × 2.032 mm cross-section. Superficial velocities of nitrogen and water ranged from 0.08 to 81.92 m/s and 0.04 to 10.24 m/s, respectively. Flow patterns were first identified using high-speed video imaging, and still photos were then taken for representative patterns. Results reveal that the dominant flow patterns are slug and annular, with bubbly flow occurring only occasionally; stratified and churn flow were never observed. A flow pattern map was constructed and compared with previous maps and predictions of flow pattern transition models. Annual flow is identified as the dominant flow pattern for conditions relevant to two-phase micro-channel heat sinks, and forms the basis for development of a theoretical model for both pressure drop and heat transfer in micro-channels. Features unique to two-phase micro-channel flow, such as laminar liquid and gas flows, smooth liquid-gas interface, and strong entrainment and deposition effects are incorporated into the model. The model shows good agreement with experimental data for water-cooled heat sinks.


1962 ◽  
Vol 28 (192) ◽  
pp. 930-939 ◽  
Author(s):  
Shu HASEGAWA ◽  
Kiyoshi YAMAGATA ◽  
Kaneyasu NISHIKAWA
Keyword(s):  

1982 ◽  
Vol 5 (3) ◽  
pp. 151-159
Author(s):  
Yung‐Chien Hsu ◽  
Ching‐Tein Liou ◽  
Jui‐Hu Shih ◽  
Tzü‐Hu Shei

2009 ◽  
Vol 131 (9) ◽  
Author(s):  
Chang Yong Park ◽  
Pega Hrnjak

Abstract C O 2 flow boiling heat transfer coefficients and pressure drop in a 3.5mm horizontal smooth tube are presented. Also, flow patterns were visualized and studied at adiabatic conditions in a 3mm glass tube located immediately after a heat transfer section. Heat was applied by a secondary fluid through two brass half cylinders to the test section tubes. This research was performed at evaporation temperatures of −15°C and −30°C, mass fluxes of 200kg∕m2s and 400kg∕m2s, and heat flux from 5kW∕m2 to 15kW∕m2 for vapor qualities ranging from 0.1 to 0.8. The CO2 heat transfer coefficients indicated the nucleate boiling dominant heat transfer characteristics such as the strong dependence on heat fluxes at a mass flux of 200kg∕m2s. However, enhanced convective boiling contribution was observed at 400kg∕m2s. Surface conditions for two different tubes were investigated with a profilometer, atomic force microscope, and scanning electron microscope images, and their possible effects on heat transfer are discussed. Pressure drop, measured at adiabatic conditions, increased with the increase of mass flux and quality, and with the decrease of evaporation temperature. The measured heat transfer coefficients and pressure drop were compared with general correlations. Some of these correlations showed relatively good agreements with measured values. Visualized flow patterns were compared with two flow pattern maps and the comparison showed that the flow pattern maps need improvement in the transition regions from intermittent to annular flow.


2019 ◽  
Vol 20 (5) ◽  
pp. 507 ◽  
Author(s):  
Lijun Deng ◽  
Jian Zhang ◽  
Guannan Hao ◽  
Jing Liu

To study factors affecting the formation and conversion of two-phase flow pattern as well as the heat transfer of piston cooling gallery, a transient visual target test bench was set up to research the oscillatory flow characteristics in the cooling gallery under idle condition of the engine. The computational fluid dynamics (CFD) was employed while dynamic mesh technology, SST k–ω turbulence model and volume of fluid (VOF) two-phase flow model were applied to simulate the flow process of piston cooling gallery so as to predict the distribution pattern of two-phase flow. Simulation results were in good agreement with that experimentally obtained. It was observed that in the reciprocating movement of the piston, the action of two-phase flow oscillation was severe, forming some unstable wave flows and slug flows. Results show that under the same pipe diameter, the increase of fluid viscosity results in the decrease of amplitude and the increase of the liquid slugs number as well as the enhancement on heat transfer effect. In addition, it was revealed that injection pressure has little effect on the two-phase flow pattern. However, when the pressure is reduced, the change of the liquid phase is weakened and the locations of flow pattern transition move towards to the behind, thus the impact on the heat transfer is also faint.


Sign in / Sign up

Export Citation Format

Share Document