scholarly journals Handheld near-infrared spectrometer allows on-line prediction of beef quality traits

Meat Science ◽  
2021 ◽  
pp. 108694
Author(s):  
Arianna Goi ◽  
Jean François Hocquette ◽  
Erika Pellattiero ◽  
Massimo De Marchi
Author(s):  
Carmen L. Manuelian ◽  
Matteo Ghetti ◽  
Claudia De Lorenzi ◽  
Marta Pozza ◽  
Marco Franzoi ◽  
...  

2021 ◽  
pp. 103206
Author(s):  
Xiting Sun ◽  
Peng Zhang ◽  
Ziwei Shen ◽  
Hongfu Yuan ◽  
Chunfeng Song ◽  
...  

1993 ◽  
Vol 47 (6) ◽  
pp. 812-815 ◽  
Author(s):  
Chris W. Brown ◽  
Su-Chin Lo

Optical-fiber measurements coupled with near-infrared spectra in the range of 5500 to 10,000 cm−1 are used to determine the optimum spectral region for remotely monitoring the energy content of natural gas at above ambient pressures. The system was configured with a Fourier transform near-infrared spectrometer and a fused-silica fiber bundle. The total energy values at a pressure of 100 psi were determined by the partial least-squares (PLS) calibration algorithm. The precision and accuracy for predicting the BTU content of an industry standard gas sample were less than 0.4% in the lower-frequency region of 5700 to 6400 cm−1.


Fuel ◽  
2019 ◽  
Vol 254 ◽  
pp. 115680 ◽  
Author(s):  
Rafaella Sales ◽  
Neirivaldo C. da Silva ◽  
Josivan P. da Silva ◽  
Higor H. França ◽  
Maria Fernanda Pimentel ◽  
...  

2008 ◽  
Vol 62 (8) ◽  
pp. 866-872 ◽  
Author(s):  
David S. Cho ◽  
Jonathon T. Olesberg ◽  
Michael J. Flanigan ◽  
Mark A. Arnold

Micromachines ◽  
2019 ◽  
Vol 10 (2) ◽  
pp. 149 ◽  
Author(s):  
Zifeng Lu ◽  
Jinghang Zhang ◽  
Hua Liu ◽  
Jialin Xu ◽  
Jinhuan Li

In the Hadamard transform (HT) near-infrared (NIR) spectrometer, there are defects that can create a nonuniform distribution of spectral energy, significantly influencing the absorbance of the whole spectrum, generating stray light, and making the signal-to-noise ratio (SNR) of the spectrum inconsistent. To address this issue and improve the performance of the digital micromirror device (DMD) Hadamard transform near-infrared spectrometer, a split waveband scan mode is proposed to mitigate the impact of the stray light, and a new Hadamard mask of variable-width stripes is put forward to improve the SNR of the spectrometer. The results of the simulations and experiments indicate that by the new scan mode and Hadamard mask, the influence of stray light is restrained and reduced. In addition, the SNR of the spectrometer also is increased.


NIR news ◽  
2019 ◽  
Vol 30 (5-6) ◽  
pp. 35-38
Author(s):  
Verena Wiedemair ◽  
Christian Wolfgang Huck

The use of ever smaller near-infrared instruments is becoming more and more prevalent, since they are cheaper, more versatile and often advertised as high-performance spectrometer. The last claim is rarely verified by independent researchers, which is why the presented work evaluates the performance of three hand-held spectrometers in comparison to a benchtop instrument. Seventy-seven samples comprising buckwheat, millet and oat were investigated for their total antioxidant capacity using Folin–Ciocalteu and near-infrared spectroscopy. Partial least squares regression models were established using cross- and test set validation. Results showed that all instruments were able to predict total antioxidant capacity to some extent. The coefficients of determinations ranged from 0.823 to 0.951 for cross-validated and from 0.849 to 0.952 for test set validated models. Errors for cross-validated models ranged from 1.11 to 2.08 mgGAE/g and for test set validated models from 1.02 to 1.86 mgGAE/g.


Sign in / Sign up

Export Citation Format

Share Document