[1.02] Catheter-based intraluminal optical coherence tomography (OCT) and endoluminal ultrasound (ELUS) in the delineation of different wall layers of porcine ureters ex vivo

2009 ◽  
Vol 24 (2) ◽  
pp. 1
Author(s):  
Ulrike Müller-Lisse ◽  
Oliver Meissner ◽  
Margit Bauer ◽  
Christoph Weber ◽  
Gregor Babaryka ◽  
...  
The Analyst ◽  
2020 ◽  
Vol 145 (4) ◽  
pp. 1445-1456 ◽  
Author(s):  
Fabian Placzek ◽  
Eliana Cordero Bautista ◽  
Simon Kretschmer ◽  
Lara M. Wurster ◽  
Florian Knorr ◽  
...  

Characterization of bladder biopsies, using a combined fiber optic probe-based optical coherence tomography and Raman spectroscopy imaging system that allows a large field-of-view imaging and detection and grading of cancerous bladder lesions.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
R Bhoite ◽  
H Jinnouchi ◽  
F Otsuka ◽  
Y Sato ◽  
A Sakamoto ◽  
...  

Abstract Background In many studies, struts coverage is defined as >0 mm of tissue overlying the stent struts by optical coherence tomography (OCT). However, this definition has never been validated using histology as the “gold standard”. The present study sought to assess the appropriate cut-off value of neointimal thickness of stent strut coverage by OCT using histology. Methods OCT imaging was performed on 39 human coronary arteries with stents from 25 patients at autopsy. A total of 165 cross-sectional images from 46 stents were co-registered with histology. The optimal cut-off value of strut coverage by OCT was determined. Strut coverage by histology was defined as endothelial cells with at least underlying two layers of smooth muscle cells. Considering the resolution of OCT is 10–20 μm, 3 different cut-off values (i.e. at ≥20, ≥40, and ≥60 μm) were assessed. Results A total of 2235 struts were evaluated by histology. Eventually, 1216 struts which were well-matched struts were analyzed in this study. By histology, uncovered struts were observed in 160 struts and covered struts were observed in 1056 struts. The broadly used definition of OCT-coverage which does not consider neointimal thickness yielded a poor specificity of 37.5% and high sensitivity 100%. Of 3 cut-off values, the cut-off value of >40 μm was more accurate as compared to >20 and >60 mm [sensitivity (99.3%), specificity (91.0%), positive predictive value (98.6%), and negative predictive value (95.6%)] Conclusion The most accurate cut-off value was ≥40 μm neointimal thickness by OCT in order to identify stent strut coverage validated by histology. Funding Acknowledgement Type of funding source: None


2002 ◽  
Vol 30 (3) ◽  
pp. 209-215 ◽  
Author(s):  
Hans Hoerauf ◽  
J�rg Winkler ◽  
Christian Scholz ◽  
Christopher Wirbelauer ◽  
Roswitha S. Gordes ◽  
...  

2021 ◽  
Vol 10 (1) ◽  
Author(s):  
Peijun Tang ◽  
Mitchell A. Kirby ◽  
Nhan Le ◽  
Yuandong Li ◽  
Nicole Zeinstra ◽  
...  

AbstractCollagen organization plays an important role in maintaining structural integrity and determining tissue function. Polarization-sensitive optical coherence tomography (PSOCT) is a promising noninvasive three-dimensional imaging tool for mapping collagen organization in vivo. While PSOCT systems with multiple polarization inputs have demonstrated the ability to visualize depth-resolved collagen organization, systems, which use a single input polarization state have not yet demonstrated sufficient reconstruction quality. Herein we describe a PSOCT based polarization state transmission model that reveals the depth-dependent polarization state evolution of light backscattered within a birefringent sample. Based on this model, we propose a polarization state tracing method that relies on a discrete differential geometric analysis of the evolution of the polarization state in depth along the Poincare sphere for depth-resolved birefringent imaging using only one single input polarization state. We demonstrate the ability of this method to visualize depth-resolved myocardial architecture in both healthy and infarcted rodent hearts (ex vivo) and collagen structures responsible for skin tension lines at various anatomical locations on the face of a healthy human volunteer (in vivo).


2009 ◽  
Vol 47 (7) ◽  
pp. e51-e52
Author(s):  
Zaid Hamdoon ◽  
Waseem Jerjes ◽  
Tahwinder Upile ◽  
Gordon McKenzie ◽  
Christian S. Betz ◽  
...  

2020 ◽  
Vol 245 (18) ◽  
pp. 1629-1636
Author(s):  
Ruiming Kong ◽  
Wenjuan Wu ◽  
Rui Qiu ◽  
Lei Gao ◽  
Fengxian Du ◽  
...  

Optical coherence tomography has become an indispensable diagnostic tool in ophthalmology for imaging the retina and the anterior segment of the eye. However, the imaging depth of optical coherence tomography is limited by light attenuation in tissues due to optical scattering and absorption. In this study of rabbit eye both ex vivo and in vivo, optical coherence tomography imaging depth of the anterior and posterior segments of the eye was extended by using optical clearing agents to reduce multiple scattering. The sclera, the iris, and the ciliary body were clearly visualized by direct application of glycerol at an incision on the conjunctiva, and the posterior boundary of sclera and even the deeper tissues were detected by submerging the posterior segment of eye in glycerol solution ex vivo or by retro-bulbar injection of glycerol in vivo. The ex vivo rabbit eyes recovered to their original state in 60 s after saline-wash treatment, and normal optical coherence tomography images of the posterior segment of the sample eyes proved the self-recovery of in vivo performance. Signal intensities of optical coherence tomography images obtained before and after glycerol treatment were compared to analysis of the effect of optical clearing. To the best of our knowledge, this is the first study for imaging depth extension of optical coherence tomography in both the anterior and posterior segments of eye by using optical clearing agents.