scholarly journals High-resolution neutron imaging: a new approach to characterize water in anodic aluminum oxides

2020 ◽  
Vol 8 ◽  
pp. 100121
Author(s):  
Noémie Ott ◽  
Claudia Cancellieri ◽  
Pavel Trtik ◽  
Patrik Schmutz
Materials ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3281
Author(s):  
Chiara Soffritti ◽  
Annalisa Fortini ◽  
Anna Nastruzzi ◽  
Ramona Sola ◽  
Mattia Merlin ◽  
...  

This work evaluates the dry sliding behavior of anodic aluminum oxides (AAO) formed during one traditional hard anodizing treatment (HA) and two golden hard anodizing treatments (named G and GP, respectively) on a EN AW-6060 aluminum alloy. Three different thicknesses of AAO layers were selected: 25, 50, and 100 μm. Prior to wear tests, microstructure and mechanical properties were determined by scanning electron microscopy (VPSEM/EDS), X-ray diffractometry, diffuse reflectance infrared Fourier transform (DRIFT-FTIR) spectroscopy, roughness, microhardness, and scratch tests. Wear tests were carried out by a pin-on-disc tribometer using a steel disc as the counterpart material. The friction coefficient was provided by the equipment. Anodized pins were weighed before and after tests to assess the wear rate. Worn surfaces were analyzed by VPSEM/EDS and DRITF-FTIR. Based on the results, the GP-treated surfaces with a thickness of 50 μm exhibit the lowest friction coefficients and wear rates. In any case, a tribofilm is observed on the wear tracks. During sliding, its detachment leads to delamination of the underlying anodic aluminum oxides and to abrasion of the aluminum substrate. Finally, the best tribological performance of G- and GP-treated surfaces may be related to the existence of a thin Ag-rich film at the coating/aluminum substrate interfaces.


2021 ◽  
Vol 7 (1) ◽  
pp. 4
Author(s):  
Katsuya Hirota ◽  
Tomoko Ariga ◽  
Masahiro Hino ◽  
Go Ichikawa ◽  
Shinsuke Kawasaki ◽  
...  

A neutron detector using a fine-grained nuclear emulsion has a sub-micron spatial resolution and thus has potential to be applied as high-resolution neutron imaging. In this paper, we present two approaches to applying the emulsion detectors for neutron imaging. One is using a track analysis to derive the reaction points for high resolution. From an image obtained with a 9 μm pitch Gd grating with cold neutrons, periodic peak with a standard deviation of 1.3 μm was observed. The other is an approach without a track analysis for high-density irradiation. An internal structure of a crystal oscillator chip, with a scale of approximately 30 μm, was able to be observed after an image analysis.


2011 ◽  
Vol 159 (2) ◽  
pp. B235-B245 ◽  
Author(s):  
P. Oberholzer ◽  
P. Boillat ◽  
R. Siegrist ◽  
R. Perego ◽  
A. Kästner ◽  
...  

2021 ◽  
pp. 2101194
Author(s):  
Xue Zhao ◽  
Tong Jin ◽  
Wanru Gao ◽  
Guangda Niu ◽  
Jinsong Zhu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document