Towards high performance Li metal batteries: Nanoscale surface modification of 3D metal hosts for pre-stored Li metal anodes

Nano Energy ◽  
2018 ◽  
Vol 54 ◽  
pp. 375-382 ◽  
Author(s):  
Keegan R. Adair ◽  
Muhammad Iqbal ◽  
Changhong Wang ◽  
Yang Zhao ◽  
Mohammad Norouzi Banis ◽  
...  
2017 ◽  
Vol 5 (48) ◽  
pp. 25368-25377 ◽  
Author(s):  
Yeong A. Lee ◽  
Jiyoung Lee ◽  
Dae Wook Kim ◽  
Chung-Yul Yoo ◽  
Sang Hyun Park ◽  
...  

The mussel-inspired surface modification for high-performance electrochemical capacitors is demonstrated.


RSC Advances ◽  
2020 ◽  
Vol 10 (40) ◽  
pp. 23749-23758
Author(s):  
Yu Wang ◽  
Wangsheng Chen ◽  
Bo Zhao ◽  
Huaqin Wang ◽  
Linbo Qin ◽  
...  

A series of activated carbons were prepared by carbonizing sugarcane bagasse combined with surface modification, which showed an excellent performance of adsorbing toluene (522 mg g−1 at 30 °C).


2017 ◽  
Vol 139 (6) ◽  
Author(s):  
X. P. Zhu ◽  
P. C. Du ◽  
Y. Meng ◽  
M. K. Lei ◽  
D. M. Guo

Inverse problem of manufacturing is studied under a framework of high performance manufacturing of components with functional surface layer, where controllable generation of surface integrity is emphasized due to its pivotal role determining final performance. Surface modification techniques capable of controlling surface integrity are utilized to verify such a framework of manufacturing, by which the surface integrity desired for a high performance can be more effectively achieved as reducing the material and geometry constraints of manufacturing otherwise unobtainable during conventional machining processes. Here, thermal spraying of WC–Ni coatings is employed to coat stainless steel components for water-lubricated wear applications, on which a strategy for direct problem from process to performance is implemented with surface integrity adjustable through spray angle and inert N2 shielding. Subsequently, multiple surface integrity parameters can be evaluated to identify the major ones responsible for wear performance by elucidating the wear mechanism, involving surface features (coating porosity and WC phase retention) and surface characteristics (microhardness, elastic modulus, and toughness). The surface features predominantly determine tribological behaviors of coatings in combination with the surface characteristics that are intrinsically associated with the surface features. Consequently, the spray process with improved N2 shielding is designed according to the desired surface integrity parameters for higher wear resistance. It is demonstrated that the correlations from processes to performance could be fully understood and established via controllable surface integrity, facilitating solution to inverse problem of manufacturing, i.e., realization of a material and geometry integrated manufacturing.


2021 ◽  
Vol 570 ◽  
pp. 151159
Author(s):  
Weishang Jia ◽  
Hudong Li ◽  
Zihao Wang ◽  
Yuchi Liu ◽  
Yao-Yue Yang ◽  
...  

2021 ◽  
pp. 088532822110511
Author(s):  
Youbin Li ◽  
Shaochuan Wang ◽  
Shidan Li ◽  
Jun Fei

Implant-related infection is a disastrous complication. Surface modification of titanium is considered as an important strategy to prevent implant-related infection. However, there is no recognized surface modification strategy that can be applied in clinic so far. We explored a new strategy of coating. The clindamycin-loaded titanium was constructed by layer-by-layer self-assembly. The release of clindamycin from titanium was detected through high performance liquid chromatography. Different titanium was co-cultured with Staphylococcus aureus for 24 h in vitro, then the effect of different titanium on bacterial colonization and biofilm formation was determined by spread plate method and scanning electron microscopy. Cytotoxicity and cytocompatibility of clindamycin-loaded titanium on MC3T3-E1 cells were measured by CCK8. The antibacterial ability of clindamycin-loaded titanium in vivo was also evaluated using a rat model of osteomyelitis. The number of osteoclasts in bone defect was observed by tartrate-resistant acid phosphatase staining. Bacterial burden of surrounding tissues around the site of infection was calculated by tissue homogenate and colony count. Clindamycin-loaded titanium could release clindamycin slowly within 160 h. It reduced bacterial colonization by three orders of magnitude compare to control ( p < .05) and inhibits biofilm formation in vitro. Cells proliferation and adhesion were similar on three titanium surfaces ( p > .05). In vivo, clindamycin-loaded titanium improved bone healing, reduced microbial burden, and decreased the number of osteoclasts compared control titanium in the rat model of osteomyelitis. This study demonstrated that clindamycin-loaded titanium exhibited good biocompatibility, and showed antibacterial activity both in vivo and in vitro. It is promising and might have potential for clinical application.


2017 ◽  
Vol 29 (8) ◽  
pp. 3572-3579 ◽  
Author(s):  
Haiping Wu ◽  
Yue Cao ◽  
Linxiao Geng ◽  
Chao Wang

Sign in / Sign up

Export Citation Format

Share Document