scholarly journals Impact of aperture-thickness on the real-time imaging characteristics of coded-aperture gamma cameras

Author(s):  
Seoryeong Park ◽  
Jiwhan Boo ◽  
Mark Hammig ◽  
Manhee Jeong
2019 ◽  
Vol 10 (33) ◽  
pp. 7690-7694 ◽  
Author(s):  
Yiming Hu ◽  
Xiaoyi Li ◽  
Yu Fang ◽  
Wen Shi ◽  
Xiaohua Li ◽  
...  

A reactive oxygen species-triggered off-on fluorescence H2S donor is develop for the real-time imaging of H2S delivery and the cytoprotection against the hazardous oxidative environment.


2007 ◽  
Vol 61 (suppl_3) ◽  
pp. ONS-146-ONS-160 ◽  
Author(s):  
Klaus D.M. Resch ◽  
H. W.S. Schroeder

Abstract Objective: To evaluate the usefulness of transendoscopic ultrasound in neurosurgery, we studied two new sonoprobes measuring 6 and 8 French in diameter in 20 fresh specimens. The application and indication are discussed in the first clinical series of 75 patients. Methods: Sonocatheters (ALOKA, Meerbusch, Germany) 1.9 mm (6 French) and 2.4 mm (8 French) in diameter were introduced into the working channel of an endoscope. The preparations were done in nonfixed skulls in a surgical simulation-setting laboratory. Based on these experiences with imaging possibilities, intraoperative transendoscopic ultrasound was applied in 75 patients and a variety of lesions. It was used for imaging (41 patients), targeting (18 patients), and neuronavigation (16 patients) in neuroendoscopy. Results: The sonoprobe adds a transverse scan at the tip of the probe to the anterior endoscopic view. This axial scan to the longitudinal axis of the endoscope is geometrically comparable with radar scanning. Three probes working with 10, 15, and 20 MHz were used, resulting in a short penetration with a radius of 3 cm. The orthogonal scanning plane had limitations, which were documented. We observed precise imaging of well known anatomic structures and, moreover, achieved an additional dimension in endoscopy. The axial scan presents the anatomic landmarks like a map at the tip of the endoscope where the endoscope is represented as a spot. The real-time imaging and representation of the tip of the endoscope showed a capacity for navigation. This preclinical study rectified clinical application. The real-time imaging of this technique showed the ability of the navigation of endoscopes to detect more overall movements, such as blood flow or change of ventricle size during endoscopy. The primary benefit in this first clinical series was witnessed in difficult endoscopy cases and complex lesions, but benefit was also observed in cases in which vision through the endoscope alone was obscured. The main limitation was the result of little penetration depth and lack of anterior scanning. Conclusion: Application of transendoscopic ultrasound is appropriate in neurosurgery. Training is necessary to understand the imaging and the geometry of scans because this technique does not scan along the axis of the endoscope. Further development to overcome the current limits of this technique and more clinical experience are needed.


2014 ◽  
Author(s):  
Irving Biederman ◽  
Ori Amir
Keyword(s):  

2015 ◽  
Vol 2 (1) ◽  
pp. 35-41
Author(s):  
Rivan Risdaryanto ◽  
Houtman P. Siregar ◽  
Dedy Loebis

The real-time system is now used on many fields, such as telecommunication, military, information system, evenmedical to get information quickly, on time and accurate. Needless to say, a real-time system will always considerthe performance time. In our application, we define the time target/deadline, so that the system should execute thewhole tasks under predefined deadline. However, if the system failed to finish the tasks, it will lead to fatal failure.In other words, if the system cannot be executed on time, it will affect the subsequent tasks. In this paper, wepropose a real-time system for sending data to find effectiveness and efficiency. Sending data process will beconstructed in MATLAB and sending data process has a time target as when data will send.


Sign in / Sign up

Export Citation Format

Share Document