Simulation study of a photoneutron source for Bragg edge transmission imaging

Author(s):  
Lu Lu ◽  
Xuewu Wang ◽  
Yigang Yang ◽  
Zhi Zhang
Author(s):  
K. A. Brookes ◽  
D. Finbow ◽  
Madeleine Samuel

Investigation of the particulate matter contained in the water sample, revealed the presence of a number of different types and certain of these were selected for analysis.An A.E.I. Corinth electron microscope was modified to accept a Kevex Si (Li) detector. To allow for existing instruments to be readily modified, this was kept to a minimum. An additional port is machined in the specimen region to accept the detector, with the liquid nitrogen cooling dewar conveniently housed in the left hand cupboard adjacent to the microscope column. Since background radiation leads to loss in the sensitivity of the instrument, great care has been taken to reduce this effect by screening and manufacturing components that are near the specimen from material of low atomic number. To change from normal transmission imaging to X-ray analysis, the special 4-position specimen rod is inserted through the normal specimen airlock.


Author(s):  
Steve Lindaas ◽  
Chris Jacobsen ◽  
Alex Kalinovsky ◽  
Malcolm Howells

Soft x-ray microscopy offers an approach to transmission imaging of wet, micron-thick biological objects at a resolution superior to that of optical microscopes and with less specimen preparation/manipulation than electron microscopes. Gabor holography has unique characteristics which make it particularly well suited for certain investigations: it requires no prefocussing, it is compatible with flash x-ray sources, and it is able to use the whole footprint of multimode sources. Our method serves to refine this technique in anticipation of the development of suitable flash sources (such as x-ray lasers) and to develop cryo capabilities with which to reduce specimen damage. Our primary emphasis has been on biological imaging so we use x-rays in the water window (between the Oxygen-K and Carbon-K absorption edges) with which we record holograms in vacuum or in air.The hologram is recorded on a high resolution recording medium; our work employs the photoresist poly(methylmethacrylate) (PMMA). Following resist “development” (solvent etching), a surface relief pattern is produced which an atomic force microscope is aptly suited to image.


2006 ◽  
Vol 11 (1) ◽  
pp. 12-24 ◽  
Author(s):  
Alexander von Eye

At the level of manifest categorical variables, a large number of coefficients and models for the examination of rater agreement has been proposed and used. The most popular of these is Cohen's κ. In this article, a new coefficient, κ s , is proposed as an alternative measure of rater agreement. Both κ and κ s allow researchers to determine whether agreement in groups of two or more raters is significantly beyond chance. Stouffer's z is used to test the null hypothesis that κ s = 0. The coefficient κ s allows one, in addition to evaluating rater agreement in a fashion parallel to κ, to (1) examine subsets of cells in agreement tables, (2) examine cells that indicate disagreement, (3) consider alternative chance models, (4) take covariates into account, and (5) compare independent samples. Results from a simulation study are reported, which suggest that (a) the four measures of rater agreement, Cohen's κ, Brennan and Prediger's κ n , raw agreement, and κ s are sensitive to the same data characteristics when evaluating rater agreement and (b) both the z-statistic for Cohen's κ and Stouffer's z for κ s are unimodally and symmetrically distributed, but slightly heavy-tailed. Examples use data from verbal processing and applicant selection.


Methodology ◽  
2016 ◽  
Vol 12 (1) ◽  
pp. 11-20 ◽  
Author(s):  
Gregor Sočan

Abstract. When principal component solutions are compared across two groups, a question arises whether the extracted components have the same interpretation in both populations. The problem can be approached by testing null hypotheses stating that the congruence coefficients between pairs of vectors of component loadings are equal to 1. Chan, Leung, Chan, Ho, and Yung (1999) proposed a bootstrap procedure for testing the hypothesis of perfect congruence between vectors of common factor loadings. We demonstrate that the procedure by Chan et al. is both theoretically and empirically inadequate for the application on principal components. We propose a modification of their procedure, which constructs the resampling space according to the characteristics of the principal component model. The results of a simulation study show satisfactory empirical properties of the modified procedure.


Methodology ◽  
2015 ◽  
Vol 11 (1) ◽  
pp. 3-12 ◽  
Author(s):  
Jochen Ranger ◽  
Jörg-Tobias Kuhn

In this manuscript, a new approach to the analysis of person fit is presented that is based on the information matrix test of White (1982) . This test can be interpreted as a test of trait stability during the measurement situation. The test follows approximately a χ2-distribution. In small samples, the approximation can be improved by a higher-order expansion. The performance of the test is explored in a simulation study. This simulation study suggests that the test adheres to the nominal Type-I error rate well, although it tends to be conservative in very short scales. The power of the test is compared to the power of four alternative tests of person fit. This comparison corroborates that the power of the information matrix test is similar to the power of the alternative tests. Advantages and areas of application of the information matrix test are discussed.


Sign in / Sign up

Export Citation Format

Share Document