A new SOLARIS beamline optimized for X-ray spectroscopy in the tender energy range

Author(s):  
Josef Hormes ◽  
Wantana Klysubun ◽  
Jost Göttert ◽  
Henning Lichtenberg ◽  
Alexey Maximenko ◽  
...  
Keyword(s):  
1987 ◽  
Vol 48 (C9) ◽  
pp. C8-669-C8-672 ◽  
Author(s):  
S. SINGH ◽  
S. KUMAR ◽  
D. MEHTA ◽  
M. L. GARG ◽  
N. SINGH ◽  
...  
Keyword(s):  

2002 ◽  
Vol 17 (12n13) ◽  
pp. 1799-1808 ◽  
Author(s):  
MARCO TAVANI

Gamma-ray astrophysics in the energy range between 30 MeV and 30 GeV is in desperate need of arcminute angular resolution and source monitoring capability. The AGILE Mission planned to be operational in 2004-2006 will be the only space mission entirely dedicated to gamma-ray astrophysics above 30 MeV. The main characteristics of AGILE are the simultaneous X-ray and gamma-ray imaging capability (reaching arcminute resolution) and excellent gamma-ray timing (10-100 microseconds). AGILE scientific program will emphasize a quick response to gamma-ray transients and multiwavelength studies of gamma-ray sources.


1976 ◽  
Vol 47 (12) ◽  
pp. 1475-1478 ◽  
Author(s):  
L. S. Birks ◽  
J. W. Sandelin ◽  
C. M. Dozier
Keyword(s):  

Author(s):  
P. Laurent ◽  
F. Acero ◽  
V. Beckmann ◽  
S. Brandt ◽  
F. Cangemi ◽  
...  

AbstractBased upon dual focusing techniques, the Polarimetric High-Energy Modular Telescope Observatory (PHEMTO) is designed to have performance several orders of magnitude better than the present hard X-ray instruments, in the 1–600 keV energy range. This, together with its angular resolution of around one arcsecond, and its sensitive polarimetry measurement capability, will give PHEMTO the improvements in scientific performance needed for a mission in the 2050 era in order to study AGN, galactic black holes, neutrons stars, and supernovae. In addition, its high performance will enable the study of the non-thermal processes in galaxy clusters with an unprecedented accuracy.


2021 ◽  
Vol 16 (11) ◽  
pp. C11014
Author(s):  
K. Malinowski ◽  
M. Chernyshova ◽  
S. Jabłoński ◽  
I. Casiragi

Abstract The paper presents an optimization of a readout structure of the GEM-based detector designed for X-ray imaging for DTT tokamak in the energy range of 2–15 keV. The readout electrode of approximately 100 cm2 surface is composed of hexagonal pixels connected in a way that allows reducing the actual number of signal pixels (electronics channels). At the same time, based on time coincidence analysis, it makes possible to unambiguously identify the position of the recorded X-ray photon. For the input spectrum, the Detective Quantum Efficiency (DQE) of the detector was calculated using the Geant4 program and the spatial distributions of electron avalanches at the readout electrode were simulated using the Garfield++ program. These were conducted for a given energy range of radiation and a statistical distribution consistent with the shape of the spectrum considering the DQE of the detector. As a result, the size of a single hexagonal pixel was proposed to capture the position of the recorded radiation quanta in an optimal and effective way.


2013 ◽  
Vol 21 (1) ◽  
pp. 273-279 ◽  
Author(s):  
L. Xue ◽  
R. Reininger ◽  
Y.-Q. Wu ◽  
Y. Zou ◽  
Z.-M. Xu ◽  
...  

A new ultrahigh-energy-resolution and wide-energy-range soft X-ray beamline has been designed and is under construction at the Shanghai Synchrotron Radiation Facility. The beamline has two branches: one dedicated to angle-resolved photoemission spectroscopy (ARPES) and the other to photoelectron emission microscopy (PEEM). The two branches share the same plane-grating monochromator, which is equipped with four variable-line-spacing gratings and covers the 20–2000 eV energy range. Two elliptically polarized undulators are employed to provide photons with variable polarization, linear in every inclination and circular. The expected energy resolution is approximately 10 meV at 1000 eV with a flux of more than 3 × 1010 photons s−1at the ARPES sample positions. The refocusing of both branches is based on Kirkpatrick–Baez pairs. The expected spot sizes when using a 10 µm exit slit are 15 µm × 5 µm (horizontal × vertical FWHM) at the ARPES station and 10 µm × 5 µm (horizontal × vertical FWHM) at the PEEM station. The use of plane optical elements upstream of the exit slit, a variable-line-spacing grating and a pre-mirror in the monochromator that allows the influence of the thermal deformation to be eliminated are essential for achieving the ultrahigh-energy resolution.


1998 ◽  
Vol 5 (3) ◽  
pp. 989-991 ◽  
Author(s):  
Andrei Rogalev ◽  
Vincent Gotte ◽  
Jose´ Goulon ◽  
Christophe Gauthier ◽  
Joel Chavanne ◽  
...  

The first experimental applications of the undulator gap-scan technique in X-ray absorption spectroscopy are reported. The key advantage of this method is that during EXAFS scans the undulator is permanently tuned to the maximum of its emission peak in order to maximize the photon statistics. In X-MCD or spin-polarized EXAFS studies with a helical undulator of the Helios type, the polarization rate can also be kept almost constant over a wide energy range.


2008 ◽  
Vol 55 (6) ◽  
pp. 3684-3691 ◽  
Author(s):  
Stratos L. David ◽  
Christos M. Michail ◽  
Ioannis G. Valais ◽  
Adrianos E. Toutountzis ◽  
Panagiotis F. Liaparinos ◽  
...  

1987 ◽  
Vol 125 ◽  
pp. 202-202
Author(s):  
Y.Q. Ma ◽  
G.H. Li ◽  
C.M. Zhang ◽  
Q.Y. Xiao ◽  
Y.M. Qian ◽  
...  

On September 22, 1985, a hard X-ray observation of Cyg X-1 was performed by using a balloon-borne CsI-NaI phoswich telescope HAPI-2 at Xianghe Balloon Facility in China. The main detector is CsI(T1) with a thickness of 0.4cm and an area of 140cm2. The energy range is 20–200KeV. The telescope reached a float altitude of about 38Km(4g/cm2). The photon's arrival time and energy loss spectrum were measured for both background and active tracking on-source observations.


Sign in / Sign up

Export Citation Format

Share Document