scholarly journals Long term cooling safe shutdown performance analysis for SMART with passive safety system using MARS-KS

Author(s):  
S.H. Bae ◽  
Y.S. Kim ◽  
N.H. Hoang ◽  
S.K. Sim
2017 ◽  
Vol 2017 ◽  
pp. 1-9
Author(s):  
Kwon-Yeong Lee ◽  
Hyun-Gi Yoon ◽  
Dong Kyou Park

An innovative integrated passive safety system for a research reactor is proposed in this study to improve the safety of the research reactor. This integrated system has three functions in the facility as a decay tank, siphon breaker, and long-term cooling tank. This paper also deals with the process of designing and optimizing the decay tank and the siphon breaker of the integrated passive safety system. At first, the decay tank was designed and improved step by step, while considering the computational fluid dynamics analysis results. Consequently, we could satisfy the design requirements of the decay tank. In addition, the performance of a new type of siphon breaker that was installed in the final decay tank model was tested. We designed an 18-inch diameter siphon breaker at the top of the decay tank’s third section, and we could observe the breaking of the siphon that prevented the occurrence of a severe accident in the research reactor. By locating the siphon breaker at the third section of the decay tank, we could also use the coolant of the front three sections for long-term cooling of the research reactor.


Author(s):  
Byong Guk Jeon ◽  
Yeon-Sik Cho ◽  
Hwang Bae ◽  
Yeon-Sik Kim ◽  
Sung-Uk Ryu ◽  
...  

2016 ◽  
Vol 98 ◽  
pp. 191-199 ◽  
Author(s):  
Hassan Nawaz Butt ◽  
Muhammad Ilyas ◽  
Masroor Ahmad ◽  
Fatih Aydogan

Author(s):  
Akira Murase ◽  
Mikihide Nakamaru ◽  
Ryoichi Hamazaki ◽  
Masahiko Kuroki ◽  
Munetaka Takahashi

Considering the delay of the first breeding reactor (FBR), it is expected that the light water reactor will still play the main role of the electric power generation in the 2030’s. Accordingly, Toshiba has been developing a new conceptual ABWR as the near-term BWR. We tentatively call it AB1600. The AB1600 has introduced the hybrid active/passive safety system in order to have independent countermeasure for severe accidents and better probability of core damage frequency (CDF) considered external events such as earthquake. On the other hand, we have another goal of the AB1600, which is to retain the safety performance superior or equivalent to the current ABWR without deterioration of economy. In order to achieve both economy and safety performance, we have optimized the safety system configuration of the AB1600 by partly introducing passive safety system to design basis event (DBEs). At the same time, we have adopted the simplification of the overall plant systems in order to improve economy. In order to reduce capital cost, to shorten refueling period and to reduce maintenance effort, the AB1600 introduces the large fuel bundle size. The bundle size is 1.2 times as large as that of the ABWR and the fuel rod array is 12 by 12. And then by progressing the core design, we can reduce the number of reactor internal pumps (RIPs) to eight from the current ABWR of ten. The core power density, the number of fuel bundles, and the core diameter of AB1600 are decided in order to achieve 24 months fuel cycle length on the condition with below 5wt% enrichment of fuel and with eight RIPs.


Author(s):  
Mian Xing ◽  
Zhaocan Meng ◽  
Xiaotao Liao ◽  
Canhui Sun ◽  
Shuming Zhang ◽  
...  

SPICRI (State Power Investment Central Research Institute) is developing a new conceptual design of heating-reactor, named Heating-reactor of Advanced low-Pressurized and Passive safetY system (HAPPY), which is targeted for the district heating, desalination of seawater, and other heat applications. It is a 200MWth two-loop low-pressurized water reactor with low thermal parameters. The whole reactor vessel is deployed inside a shielding and cooling pool with thermal insulation measure. The conceptual design of HAPPY is described in this paper, including the design criteria, safety features, main parameters and main components. A preliminary safety analysis is carried out to provide a reference for the design and optimization of HAPPY. In this paper, four different LOCA analyses are described and compared. The results show that the current design can deal well with all the selected LOCA scenarios and the effectiveness of the safety systems is proved.


Sign in / Sign up

Export Citation Format

Share Document