scholarly journals High Speed 3D Motion Capture System for Flying Golf Ball

2011 ◽  
Vol 19 ◽  
pp. 214-219 ◽  
Author(s):  
Yi-Hong Lin ◽  
Wen-Hong Wu ◽  
Wei-Zhe Huang
Author(s):  
Jonathan Kenneth Sinclair ◽  
Lindsay Bottoms

AbstractRecent epidemiological analyses in fencing have shown that injuries and pain linked specifically to fencing training/competition were evident in 92.8% of fencers. Specifically the prevalence of Achilles tendon pathology has increased substantially in recent years, and males have been identified as being at greater risk of Achilles tendon injury compared to their female counterparts. This study aimed to examine gender differences in Achilles tendon loading during the fencing lunge.Achilles tendon load was obtained from eight male and eight female club level epee fencers using a 3D motion capture system and force platform information as they completed simulated lunges. Independent t-tests were performed on the data to determine whether differences existed.The results show that males were associated with significantly greater Achilles tendon loading rates in comparison to females.This suggests that male fencers may be at greater risk from Achilles tendon pathology as a function of fencing training/ competition.


2017 ◽  
Vol 49 (5S) ◽  
pp. 757
Author(s):  
Jessica L. Halle ◽  
Jacob A. Goldsmith ◽  
Cameron Trepeck ◽  
Ryan K. Byrnes ◽  
Daniel M. Cooke ◽  
...  

Author(s):  
Per-Anders Fransson ◽  
Maria H. Nilsson ◽  
Diederick C. Niehorster ◽  
Marcus Nyström ◽  
Stig Rehncrona ◽  
...  

Abstract Background Tremor is a cardinal symptom of Parkinson’s disease (PD) that may cause severe disability. As such, objective methods to determine the exact characteristics of the tremor may improve the evaluation of therapy. This methodology study aims to validate the utility of two objective technical methods of recording Parkinsonian tremor and evaluate their ability to determine the effects of Deep Brain Stimulation (DBS) of the subthalamic nucleus and of vision. Methods We studied 10 patients with idiopathic PD, who were responsive to L-Dopa and had more than 1 year use of bilateral subthalamic nucleus stimulation. The patients did not have to display visible tremor to be included in the study. Tremor was recorded with two objective methods, a force platform and a 3 dimensional (3D) motion capture system that tracked movements in four key proximal sections of the body (knee, hip, shoulder and head). They were assessed after an overnight withdrawal of anti-PD medications with DBS ON and OFF and with eyes open and closed during unperturbed and perturbed stance with randomized calf vibration, using a randomized test order design. Results Tremor was detected with the Unified Parkinson’s Disease Rating Scale (UPDRS) in 6 of 10 patients but only distally (hands and feet) with DBS OFF. With the force platform and the 3D motion capture system, tremor was detected in 6 of 10 and 7 of 10 patients respectively, mostly in DBS OFF but also with DBS ON in some patients. The 3D motion capture system revealed that more than one body section was usually affected by tremor and that the tremor amplitude was non-uniform, but the frequency almost identical, across sites. DBS reduced tremor amplitude non-uniformly across the body. Visual input mostly reduced tremor amplitude with DBS ON. Conclusions Technical recording methods offer objective and sensitive detection of tremor that provide detailed characteristics such as peak amplitude, frequency and distribution pattern, and thus, provide information that can guide the optimization of treatments. Both methods detected the effects of DBS and visual input but the 3D motion system was more versatile in that it could detail the presence and properties of tremor at individual body sections.


2016 ◽  
Vol 53 (1) ◽  
pp. 22-29 ◽  
Author(s):  
Xiangyang Ju ◽  
Emer O'leary ◽  
Matthew Peng ◽  
Thamer Al-Anezi ◽  
Ashraf Ayoub ◽  
...  

Healthcare ◽  
2021 ◽  
Vol 9 (8) ◽  
pp. 1076
Author(s):  
Laisi Cai ◽  
Dongwei Liu ◽  
Ye Ma

Low-cost, portable, and easy-to-use Kinect-based systems achieved great popularity in out-of-the-lab motion analysis. The placement of a Kinect sensor significantly influences the accuracy in measuring kinematic parameters for dynamics tasks. We conducted an experiment to investigate the impact of sensor placement on the accuracy of upper limb kinematics during a typical upper limb functional task, the drinking task. Using a 3D motion capture system as the golden standard, we tested twenty-one Kinect positions with three different distances and seven orientations. Upper limb joint angles, including shoulder flexion/extension, shoulder adduction/abduction, shoulder internal/external rotation, and elbow flexion/extension angles, are calculated via our developed Kinect kinematic model and the UWA kinematic model for both the Kinect-based system and the 3D motion capture system. We extracted the angles at the point of the target achieved (PTA). The mean-absolute-error (MEA) with the standard represents the Kinect-based system’s performance. We conducted a two-way repeated measure ANOVA to explore the impacts of distance and orientation on the MEAs for all upper limb angles. There is a significant main effect for orientation. The main effects for distance and the interaction effects do not reach statistical significance. The post hoc test using LSD test for orientation shows that the effect of orientation is joint-dependent and plane-dependent. For a complex task (e.g., drinking), which involves body occlusions, placing a Kinect sensor right in front of a subject is not a good choice. We suggest that place a Kinect sensor at the contralateral side of a subject with the orientation around 30∘ to 45∘ for upper limb functional tasks. For all kinds of dynamic tasks, we put forward the following recommendations for the placement of a Kinect sensor. First, set an optimal sensor position for capture, making sure that all investigated joints are visible during the whole task. Second, sensor placement should avoid body occlusion at the maximum extension. Third, if an optimal location cannot be achieved in an out-of-the-lab environment, researchers could put the Kinect sensor at an optimal orientation by trading off the factor of distance. Last, for those need to assess functions of both limbs, the users can relocate the sensor and re-evaluate the functions of the other side once they finish evaluating functions of one side of a subject.


Motor Control ◽  
2021 ◽  
pp. 1-36
Author(s):  
Bryony Buck ◽  
Scott Beveridge ◽  
Gerard Breaden Madden ◽  
Hans-Christian Jabusch

Background: High-speed drumming requires precise control over the timing, velocity, and magnitude of striking movements. Aim: To examine effects of tempo and expertise on unaccented repetitive drumming performance using 3D motion capture. Methods: Expert and amateur drummers performed unimanual, unaccented, repetitive drum strikes, using their dominant right hand, at five different tempi. Performance was examined with regard to timing variability, striking velocity variability, the ability to match the prescribed tempo, and additional variables. Results: Permutated multivariate analysis of variance (PERMANOVA) revealed significant main effects of tempo (p < .001) and expertise (p <.001) on timing variability and striking velocity variability; low timing variability and low striking velocity variability were associated with low/medium tempo as well as with increased expertise. Individually, improved precision appeared across an optimum tempo range. Precision was poorest at maximum tempo (400 hits per minute) for precision variables. Conclusions: Expert drummers demonstrated greater precision and consistency than amateurs. Findings indicate an optimum tempo range that extends with increased expertise.


2016 ◽  
Vol 31 (4) ◽  
pp. 591-596 ◽  
Author(s):  
Yu HORIMIZU ◽  
Minoru KIMOTO ◽  
Yoshino TERUI ◽  
Akiho TAKAHASHI ◽  
Tomoko FUKUI ◽  
...  

Author(s):  
Jenny Clarke

This study investigated the relationship between wrist flexion and the dynamics of the swing of a croquet mallet. Twenty seven subjects participated in a study which used 3D motion capture equipment and high speed and high-definition video to determine if there is a correlation between the lateral twist of a croquet player&rsquo;s swing and the flexion of the wrist during that swing. The study found a significant correlation between the amount of flexion of the wrist from the start of the stroke to the top of the backswing and the twist of the mallet head at the top of the backswing (r=0.330, p&lt;0.01). The methodology and findings are relevant to all sports where minimising wrist flexion is favourable for improving consistency of stroke making. Additionally, reducing wrist motion in stroke-making may reduce the incidence of wrist pain and injury in croquet, further supporting recommendations to reduce the amount of wrist flexion during the croquet swing.


Sign in / Sign up

Export Citation Format

Share Document