scholarly journals Optimization of Wind Tower Cooling Performance: A Wind Tunnel Study of Indoor Air Movement and Thermal Comfort

2017 ◽  
Vol 180 ◽  
pp. 611-620 ◽  
Author(s):  
Mahsan Sadeghi ◽  
Richard de Dear ◽  
Bijan Samali ◽  
Graeme Wood
2021 ◽  
Vol 16 (3) ◽  
pp. 774-793
Author(s):  
Nur Baitul Izati Rasli ◽  
Nor Azam Ramli ◽  
Mohd Rodzi Ismail

This study observed the influence of different ventilation, indoor and outdoor activities (i.e., cooking, praying, sweeping, gathering, and exhaust from motorcycle) between a bungalow house (i.e., stack and cross ventilation applications) and a terrace house (i.e., one-sided ventilation application). We appraised the indoor air quality (IAQ) and thermal comfort. We monitored the indoor air contaminants (i.e., TVOC, CO, CH2O, PM10, O3, and CO2) and specific physical parameters (i.e., T, RH, and AS) for four days in the morning (i.e., 6.00 a.m. – 9.00 a.m.), morning-evening (i.e., 11.00 a.m. – 2.00 p.m.), and evening-night (i.e., 5.00 p.m. – 8.00 p.m.) sessions. The results found that cooking activities are the major activities that contributed to the increase of the TVOC, CO, PM10, O3, and CO2 concentrations in the bungalow and terrace houses. However, IAQ exceeded the Industry Code of Practice on IAQ (ICOP) limit in the terrace house. The bungalow house applies stack and cross ventilation, double area, and a long pathway of indoor air contaminants movements. Besides that, the results indicated that cooking activities worsen the ventilation system because CO2 exceeded the ICOP limit on Day 2 at 74.1 % (evening-night session) and Day 3 at 13.2 % (morning session), 11% (morning-evening session), and 50.1 % (evening-night session). Moreover, the combination of mechanical (i.e., opened all fans) and natural ventilation (i.e., opened all doors, windows, and fans) is the best application in the house without a cooking ventilator with lower indoor air movement. Furthermore, the temperatures exceeding the ICOP limit of 23-26 °C for both bungalow and terrace houses could be lower indoor air movement, which is less than the ICOP limit of 0.15-0.5 m/s and high outdoor air temperature. Therefore, it is prudent to have an efficient ventilation system for acceptable indoor air quality and thermal comfort in the family house.


2002 ◽  
Vol 14 (04) ◽  
pp. 175-181
Author(s):  
TANG-JEN LIU ◽  
MING-SHING YOUNG

Opening windows is frequently done to refresh the indoor air for the occupants. To maintain the cleanliness and freshness of the indoor air, more outdoor air is needed. But its high temperature and humidity are harmful to the thermal comfort of the indoor environment. Therefore, determining the amount of outdoor air allowed to enter the room is very important for the optimum conditioning of the indoor air. The ASHRAE comfort charts indicate the percentage of subjects feeling comfortable during various combinations of dry-bulb temperature, humidity, and air movement. A set of mathematical expressions were proposed to model the charts in order to calculate the comfort degree of the outdoor air automatically with its temperature and humidity. In this paper, the measurement of temperature and humidity was completed by a self-developed digital method. Besides, the comfort level of the sampled air was also simultaneously determined by this digital method based on the mathematical model of comfort charts. The system implemented based on our method is portable. This will let us make good use of the outdoor air and controll the ventilation machine more effectively.


2021 ◽  
Vol 35 (4) ◽  
pp. 1757-1770
Author(s):  
Ho Yeon Choi ◽  
Jae Hyun Oh ◽  
Man Su Park ◽  
Sai Kee Oh ◽  
Yong Gap Park ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document