Total sulfur determination in gasoline, kerosene and diesel fuel using inductively coupled plasma optical emission spectrometry after direct sample introduction as detergent emulsions

2008 ◽  
Vol 63 (7) ◽  
pp. 800-804 ◽  
Author(s):  
Ricardo Erthal Santelli ◽  
Eliane Padua Oliveira ◽  
Maria de Fátima Batista de Carvalho ◽  
Marcos Almeida Bezerra ◽  
Aline Soares Freire
2020 ◽  
Vol 35 (6) ◽  
pp. 1125-1130 ◽  
Author(s):  
Ahmed Al Hejami ◽  
Mirah J. Burgener ◽  
John Burgener ◽  
Diane Beauchemin

A compact infrared-heated sample introduction system provides similar analytical performance with higher robustness and faster washout than commercially available nebulization systems.


2017 ◽  
Vol 2 (1) ◽  
Author(s):  
Man He ◽  
Bin Hu ◽  
Beibei Chen ◽  
Zucheng Jiang

Abstract Inductively coupled plasma optical emission spectrometry (ICP-OES) merits multielements capability, high sensitivity, good reproducibility, low matrix effect and wide dynamic linear range for rare earth elements (REEs) analysis. But the spectral interference in trace REEs analysis by ICP-OES is a serious problem due to the complicated emission spectra of REEs, which demands some correction technology including interference factor method, derivative spectrum, Kalman filtering algorithm and partial least-squares (PLS) method. Matrix-matching calibration, internal standard, correction factor and sample dilution are usually employed to overcome or decrease the matrix effect. Coupled with various sample introduction techniques, the analytical performance of ICP-OES for REEs analysis would be improved. Compared with conventional pneumatic nebulization (PN), acid effect and matrix effect are decreased to some extent in flow injection ICP-OES, with higher tolerable matrix concentration and better reproducibility. By using electrothermal vaporization as sample introduction system, direct analysis of solid samples by ICP-OES is achieved and the vaporization behavior of refractory REEs with high boiling point, which can easily form involatile carbides in the graphite tube, could be improved by using chemical modifier, such as polytetrafluoroethylene and 1-phenyl-3-methyl-4-benzoyl-5-pyrazone. Laser ablation-ICP-OES is suitable for the analysis of both conductive and nonconductive solid samples, with the absolute detection limit of ng-pg level and extremely low sample consumption (0.2 % of that in conventional PN introduction). ICP-OES has been extensively employed for trace REEs analysis in high-purity materials, and environmental and biological samples.


Sign in / Sign up

Export Citation Format

Share Document