On-line/on-site analysis of heavy metals in water and soils by laser induced breakdown spectroscopy

2017 ◽  
Vol 137 ◽  
pp. 39-45 ◽  
Author(s):  
Deshuo Meng ◽  
Nanjing Zhao ◽  
Yuanyuan Wang ◽  
Mingjun Ma ◽  
Li Fang ◽  
...  
The Analyst ◽  
2019 ◽  
Vol 144 (11) ◽  
pp. 3567-3572 ◽  
Author(s):  
Pengfei Zhang ◽  
Zhixuan Huang ◽  
Yiwen Ma ◽  
Yang Li ◽  
Naqash Ali ◽  
...  

A portable laser-induced breakdown spectroscopy (PLIBS) device is proposed for on-line detection of radioactive and non-radioactive heavy metals in tobacco smoke with ultra-high sensitivity.


2019 ◽  
Vol 27 (8) ◽  
pp. A495 ◽  
Author(s):  
N. J. Zhao ◽  
D. S. Meng ◽  
Y. Jia ◽  
M. J. Ma ◽  
L. Fang ◽  
...  

2012 ◽  
Vol 39 (2) ◽  
pp. 0215001 ◽  
Author(s):  
闫静 Yan Jing ◽  
丁蕾 Ding Lei ◽  
葛琳琳 Ge Linlin ◽  
王颖萍 Wang Yingping ◽  
郑海洋 Zheng Haiyang ◽  
...  

2019 ◽  
Vol 48 (10) ◽  
pp. 1005006
Author(s):  
李业秋 Li Yeqiu ◽  
孙成林 Sun Chenglin ◽  
李 倩 Li Qian ◽  
岱 钦 Dai Qin ◽  
乌日娜 Wu Rina ◽  
...  

2019 ◽  
Vol 11 (29) ◽  
pp. 3657-3664 ◽  
Author(s):  
Yu Ding ◽  
Guiyu Xia ◽  
Huiwen Ji ◽  
Xiong Xiong

A rapid detection method for heavy metals in oily soil is needed to provide accurate data support for in situ soil pollution assessment and restoration.


2009 ◽  
Vol 63 (8) ◽  
pp. 865-872 ◽  
Author(s):  
Wangbao Yin ◽  
Lei Zhang ◽  
Lei Dong ◽  
Weiguang Ma ◽  
Suotang Jia

It is vitally important for a power plant to determine the chemical composition of coal prior to combustion in order to obtain optimal boiler control. In this work, a fully software-controlled laser-induced breakdown spectroscopy (LIBS) system comprising a LIBS apparatus and sampling equipment has been designed for possible application to power plants for on-line quality analysis of pulverized coal. Special attention was given to the LIBS system, the data processing methods (especially the normalization with Bode Rule/DC Level) and the specific settings (the software-controlled triggering source, high-pressure gas cleaning device, sample-preparation module, sampling module, etc.), which gave the best direct measurement for C, H, Si, Na, Mg, Fe, Al, and Ti with measurement errors less than 10% for pulverized coal. Therefore, the apparatus is accurate enough to be applied to industries for on-line monitoring of pulverized coal. The method of proximate analysis was also introduced and the experimental error of Aad (Ash, ‘ad’ is an abbreviation for ‘air dried’) was shown in the range of 2.29 to 13.47%. The programmable logic controller (PLC) controlled on-line coal sampling equipment, which is designed based upon aerodynamics, and is capable of performing multipoint sampling and sample-preparation operation.


Sign in / Sign up

Export Citation Format

Share Document