Construction of skin-electrode mechanosensing structure for wearable and epidermal electronic sensor

2021 ◽  
Author(s):  
Wenke Yang ◽  
Hu Liu ◽  
Chuntai Liu ◽  
Changyu Shen
2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Ran Zhao ◽  
Yanqing Liu ◽  
Hua Tian

Abstract Background Soft tissue balancing is essential for the success of total knee arthroplasty (TKA) and is mainly dependent on surgeon-defined assessment (SDA) or a gap-balancer (GB). However, an electronic sensor has been developed to objectively measure the gap pressure. This study aimed to evaluate the accuracy of soft tissue balancing using SDA and GB compared with a sensor. Methods Forty-eight patients undergoing TKA (60 knees) were prospectively enrolled. Soft tissue balancing was sequentially performed using SDA, a GB, and an electronic sensor. We compared the SDA, GB, and sensor data to calculate the sensitivity, specificity, and accuracy at 0°, 45°, 90°, and 120° flexion. Cumulative summation (CUSUM) analysis was performed to assess the surgeon’s performance during the sensor introductory phase. Results The sensitivity of SDA was 63.3%, 68.3%, 80.0%, and 80.0% at 0°, 45°, 90°, and 120°, respectively. The accuracy of the GB compared with sensor data was 76.7% and 71.7% at 0° and 90°, respectively. Cohen’s kappa coefficient for the accuracy of the GB was 0.406 at 0° (moderate agreement) and 0.227 at 90° (fair agreement). The CUSUM 0° line achieved good prior performance at case 45, CUSUM 90° and 120° showed a trend toward good prior performance, while CUSUM 45° reached poor prior performance at case 8. Conclusion SDA was a poor predictor of knee balance. GB improved the accuracy of soft tissue balancing, but was still less accurate than the sensor, particularly for unbalanced knees. SDA improved with ongoing use of the sensor, except at 45° flexion.


2021 ◽  
Author(s):  
Krasimir Cheshmedzhiev ◽  
Evgeniya Gospodinova ◽  
Mitko Gospodinov ◽  
Penio Lebamovski

2021 ◽  
Author(s):  
Marco Tartagni

Get up to speed with the fundamentals of electronic sensor design with this comprehensive guide, and discover powerful techniques to reduce the overall design timeline for your specific applications. Includes a step-by-step introduction to a generalized information-centric approach for designing electronic sensors, demonstrating universally applicable practical approaches to speed up the design process. Features detailed coverage of all the tools necessary for effective characterization and organization of the design process, improving overall process efficiency. Provides a coherent and rigorous theoretical framework for understanding the fundamentals of sensor design, to encourage an intuitive understanding of sensor design requirements. Emphasising an integrated interdisciplinary approach throughout, this is an essential tool for professional engineers and graduate students keen to improve their understanding of cutting-edge electronic sensor design.


Sensors ◽  
2017 ◽  
Vol 17 (8) ◽  
pp. 1757 ◽  
Author(s):  
Csongor Gedeon ◽  
Norbert Flórián ◽  
Péter Liszli ◽  
Beáta Hambek-Oláh ◽  
Oxána Bánszegi ◽  
...  

2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Jinzhong Song ◽  
Tianshu Zhou ◽  
Zhonggang Liang ◽  
Ruoxi Liu ◽  
Jianping Guo ◽  
...  

Based on one simulated skin-electrode electrochemical interface, some electrochemical characteristics based on skin-electrode contact pressure (SECP) for dry biomedical electrodes were analysed and applied in this research. First, 14 electrochemical characteristics including 2 static impedance (SI) characteristics, 11 alternating current impedance (ACI) characteristics and one polarization voltage (PV), and 4 SECP characteristics were extracted in one electrochemical evaluation platform, and their correlation trends were statistically analysed. Second, dry biomedical electrode samples developed by the company and the laboratory, including textile electrodes, Apple watch, AMAZFIT rice health bracelet 1S, and stainless steel electrodes, were placed horizontally and vertically on the “skin” surface of the electrochemical evaluation platform, whose polarization voltages were quantitatively analysed. Third, electrocardiogram (ECG) collection circuits based on an impedance transformation (IT) circuit for textile electrodes were designed, and a wearable ECG acquisition device was designed, which could obtain complete ECG signals. Experimental results showed SECP characteristics for dry electrodes had good correlations with static impedance and ACI characteristics and the better correlation values among 2-10 Hz. In addition, polarization voltages in vertical state were smaller in horizontal state for dry biomedical electrodes, and polarization voltage of electrode pair (PVEP) values for Apple watch bottom was always smaller than ones for Apple watch crown and LMF-2 textile electrode. And the skin-electrode contact impedance of IT textile electrodes was less than the traditional textile electrodes.


Sign in / Sign up

Export Citation Format

Share Document