Confining signal probe in porous PdPtCoNi@Pt-skin nanopolyhedra to construct a sandwich-type electrochemical immmunosensor for ultrasensitive detection of creatine kinase-MB

2020 ◽  
Vol 315 ◽  
pp. 128088 ◽  
Author(s):  
Xiao-Yu Wang ◽  
Yao Chen ◽  
Li-Ping Mei ◽  
Ai-Jun Wang ◽  
Pei-Xin Yuan ◽  
...  
1984 ◽  
Vol 30 (8) ◽  
pp. 1399-1401 ◽  
Author(s):  
J J Fenton ◽  
S Brunstetter ◽  
W C Gordon ◽  
D F Rippe ◽  
M L Bell

Abstract A new commercial enzyme immunoassay kit for quantification of creatine kinase-MB (CK-MB) isoenzyme was compared with its electrophoretic determination with respect to efficacy in diagnosis of acute myocardial infarction. Enzygnost CK-MB (Behring Diagnostics) is a solid-phase "sandwich"-type enzyme immunoassay with antibodies to the B-subunit coated on plastic tubes and peroxidase-conjugated antibodies to the M-subunit added after incubation with sample. This kit is designed to measure only CK-MB and not CK-MM, CK-BB, adenylate kinase, or atypical CK molecules. The linear-regression equation comparing the two methods was: Enzygnost = 0.98 . electrophoresis - 0.72, with a correlation coefficient of r = 0.967 (n = 143). For 51 patients admitted for diagnosis of possible acute myocardial infarction, the Enzygnost kit achieved 100% sensitivity, specificity, and efficiency in predicting the correct diagnosis. Corresponding values for the electrophoretic assay were: 95.5% sensitivity, 93.1% specificity, and 94.1% efficiency. We conclude that this kit method provides an excellent alternative to electrophoresis.


Circulation ◽  
1995 ◽  
Vol 92 (7) ◽  
pp. 1927-1932 ◽  
Author(s):  
Kurt Bachmaier ◽  
Johannes Mair ◽  
Felix Offner ◽  
Christian Pummerer ◽  
Nikolaus Neu

1985 ◽  
Vol 71 (5) ◽  
pp. 463-468 ◽  
Author(s):  
Giovanni Carulli ◽  
Aldo Clerico ◽  
Alessandra Marini ◽  
Maria Grazia Del Chicca ◽  
Renato Vanacore ◽  
...  

The modifications in the concentration of circulating myoglobin have been studied by means of a radioimmunoassay in 15 cancer patients undergoing polychemotherapy including adriamycin. In 8 patients significant increases in myoglobin levels were found after injection of low doses of the drug (25-50 mg/m2). Moreover, a disturbance of the normal biorhythm of the protein was evident in 12 patients. Creatine kinase-MB was evaluated by means of a radioimmunoassay, but there was no relation between an increase in the isoenzyme and an increase in myoglobin. No ECG modifications were detected. These data indicate that the measurement of myoglobin may offer an indication of myocardial or skeletal muscle damage caused by adriamycin.


Author(s):  
Qing H Meng ◽  
William C Irwin ◽  
Jennifer Fesser ◽  
K Lorne Massey

Background: Ascorbic acid can interfere with methodologies involving redox reactions, while comprehensive studies on main chemistry analysers have not been reported. We therefore attempted to determine the interference of ascorbic acid with analytes on the Beckman Synchron LX20®. Methods: Various concentrations of ascorbic acid were added to serum, and the serum analytes were measured on the LX20. Results: With a serum ascorbic acid concentration of 12.0 mmol/L, the values for sodium, potassium, calcium and creatinine increased by 43%, 58%, 103% and 26%, respectively ( P<0.01). With a serum ascorbic acid concentration of 12.0 mmol/L, the values for chloride, total bilirubin and uric acid decreased by 33%, 62% and 83%, respectively ( P<0.01), and were undetectable for total cholesterol, triglyceride, ammonia and lactate. There was no definite influence of ascorbic acid on analytical values for total CO2, urea, glucose, phosphate, total protein, albumin, amylase, creatine kinase, creatine kinase-MB, aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase, total iron, unbound iron-binding capacity or magnesium. Conclusions: Ascorbic acid causes a false increase in sodium, potassium, calcium and creatinine results and a false decrease in chloride, total bilirubin, uric acid, total cholesterol, triglyceride, ammonia and lactate results.


2011 ◽  
Vol 12 (10) ◽  
pp. 736-740 ◽  
Author(s):  
Fabrizio Ricci ◽  
Raffaele De Caterina

2012 ◽  
Vol 164 (5) ◽  
pp. 779-785 ◽  
Author(s):  
Camilla Lund Søraas ◽  
Charlotte Friis ◽  
Kristin Victoria Tunheim Engebretsen ◽  
Leiv Sandvik ◽  
Sverre Erik Kjeldsen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document