Signal on-off ratiometric electrochemical sensor based on semi-complementary aptamer couple for sensitive cadmium detection in mussel

2021 ◽  
pp. 130506
Author(s):  
Zhiyu Chen ◽  
Chao Liu ◽  
Xiaoyu Su ◽  
Wen Zhang ◽  
Xiaobo Zou
Sensors ◽  
2019 ◽  
Vol 19 (24) ◽  
pp. 5482 ◽  
Author(s):  
Jingheng Ning ◽  
Xin Luo ◽  
Faxiang Wang ◽  
Shouen Huang ◽  
Jianhui Wang ◽  
...  

In the present work, a novel electrochemical sensor was developed for the detection of trace cadmium with high sensitivity and selectivity in an easy and eco-friendly way. Firstly, a glassy carbon electrode (GCE) was modified with nontoxic sodium carboxymethyl cellulose (CMC) by a simple drop-casting method, which was applied to detect cadmium by differential pulse anodic stripping voltammetry (DPASV) in a solution containing both target cadmium and eco-friendly bismuth ions, based on a quick electro-codeposition of these two metal ions on the surface of the modified electrode (CMC-GCE). Investigated by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and Fourier transform infrared spectroscopy (FT-IR), both CMC (with good film-forming ability) and bismuth (with well-defined stripping signal) were found to be well complexed with target cadmium, leading to vital signal amplification for cadmium detection at a sub-nanomolar level. Under the optimal conditions, the proposed sensor exhibited a good linear stripping signal response to cadmium (Ⅱ) ion, in a concentration range of 0.001 μmol/L–1 μmol/L with a limit of detection of 0.75 nmol/L (S/N = 3). Meanwhile, the results demonstrate that this novel electrochemical sensor has excellent sensitivity and reproducibility, which can be used as a promising detection technique for testing natural samples such as tap water.


2020 ◽  
Vol 16 (4) ◽  
pp. 424-437
Author(s):  
Kubra Ozturk ◽  
Nurgul K. Bakirhan ◽  
Sibel A. Ozkan ◽  
Bengi Uslu

Background:: new and selective electrochemical sensor was developed for the determination of levocetirizine dihydrochloride, which is an antihistaminic drug. Method:: The investigation was performed by using cyclic, differential pulse and square wave voltammetric methods on the β-cyclodextrin modified glassy carbon electrode. It is thereby planned to obtain information about levocetirizine determination and its mechanism. Result:: The efficiency of experimental parameters including pH, scan rate, and accumulation potential and time on the anodic response of levocetirizine dihydrochloride was studied. By employing the developed method and under optimized conditions, the current showed linear dependence with a concentration in the range between 2 × 10-8 M and 6 × 10-6 M in pH 2.0 Britton Robinson (BR) buffer. Conclusion:: The achieved limits of detection and quantification were found as 3.73 × 10-10 M and 1.24 × 10-9 M, respectively. In addition, the possibility of applying the developed sensor for real sample analysis was investigated, so β-cyclodextrin modified glassy carbon electrode was used to determine levocetirizine dihydrochloride in Xyzal® tablet dosage form. Finally, this sensor was successfully applied to the real sample as a selective, simple, reproducible, repeatable electrochemical sensor.


2020 ◽  
Vol 16 (3) ◽  
pp. 341-348
Author(s):  
Surinya Traipop ◽  
Suchada Chuanuwatanakul ◽  
Orawon Chailapakul ◽  
Eakkasit Punrat

Background: Recently, Derris scandens, a Thai herbal medicine with anti-inflammatory activity, is widely used as beverage and supplementary food. When the traditional medicine is a choice for health therapy, the simple and reliable equipment is required to control the suitable consuming amount of the active component. Objective: To develop the electrochemical sensor for genistein determination in Derris scandens with high sensitivity and rapid operation. Methods: An in-house screen-printed electrochemical sensor consisting of a three-electrode system was developed for genistein determination. A silver/silver chloride (Ag/AgCl) reference electrode, a carbon counter electrode and a carbon working electrode were prepared on a 0.3-mm-thick plastic substrate by the screen-printing technique using conductive ink. The dimensions of each sensor were 2.5×1.0 cm. Only 50 µL of sample solution was required on this device for the determination of genistein concentration by rapid response square wave voltammetry. Results: The oxidation peak of genistein appeared with good response in acidic media at a peak potential of 0.6 V. Moreover, the signal was enhanced by modifying the conductive carbon ink with cobalt( II) phthalocyanine. Under the optimized conditions, the linear range was found to be 2.5-150 µM and the detection limit was 1.5 µM. Moreover, the small volume extraction was successfully developed without any further pre-concentration. This proposed method was applied to determine genistein in Derris scandens with satisfying results. Conclusion: The proposed method is promising as an alternative method for genistein determination with facile and fast analysis.


2015 ◽  
Vol 11 (4) ◽  
pp. 237-243 ◽  
Author(s):  
Zhou Yaoyu ◽  
Tang Lin ◽  
Xie Xia ◽  
Zeng Guangming ◽  
Gong Jilai ◽  
...  

2020 ◽  
Vol 16 (4) ◽  
pp. 413-420 ◽  
Author(s):  
Youyuan Peng ◽  
Qiaolan Ji

Background: As a broad-spectrum antibiotic of the sulfonamide family, Sulfadimethoxine (SDM) has been widely utilized for therapeutic and growth-promoting purposes in animals. However, the use of SDM can cause residual problems. Even a low concentration of SDM in the aquatic system can exert toxic effects on target organisms and green algae. Therefore, the quantitation of SDM residues has become an important task. Methods: The present work describes the development of a sensitive and selective electrochemical sensor for sulfadimethoxine based on molecularly imprinted poly(o-aminophenol) film. The molecular imprinted polymer film was fabricated by electropolymerizing o-aminophenol in the presence of SDM after depositing carboxylfunctionalized multi-walled carbon nanotubes onto a glassy carbon electrode surface. SDM can be quickly removed by electrochemical methods. The imprinted polymer film was characterized by cyclic voltammetry, differential pulse voltammetry and scanning electron microscopy. Results: Under the selected optimal conditions, the molecularly imprinted sensor shows a linear range from 1.0 × 10-7 to 2.0 × 10-5 mol L-1 for SDM, with a detection limit of 4.0 × 10-8 mol L-1. The sensor was applied to the determination of SDM in aquaculture water samples successfully, with the recoveries ranging from 95% to 106%. Conclusion: The proposed sensor exhibited a high degree of selectivity for SDM in comparison to other structurally similar molecules, along with long-term stability, good reproducibility and excellent regeneration capacity. The sensor may offer a feasible strategy for the analysis of SDM in aquaculture water samples.


2019 ◽  
Vol 15 (6) ◽  
pp. 628-634
Author(s):  
Rong Liu ◽  
Jie Li ◽  
Tongsheng Zhong ◽  
Liping Long

Background: The unnatural levels of dopamine (DA) result in serious neurological disorders such as Parkinson’s disease. Electrochemical methods which have the obvious advantages of simple operation and low-cost instrumentation were widely used for determination of DA. In order to improve the measurement performance of the electrochemical sensor, molecular imprinting technique and graphene have always been employed to increase the selectivity and sensitivity. Methods: An electrochemical sensor which has specific selectivity to (DA) was proposed based on the combination of a molecular imprinting polymer (MIP) with a graphene (GR) modified gold electrode. The performance and effect of MIP film were investigated by differential pulse voltammetry (DPV) and cyclic voltammetry (CV) in the solution of 5.0 ×10-3 mol/L K3[Fe(CN)6] and K4[Fe(CN)6] with 0.2 mol/L KCl at room temperature. Results: This fabricated sensor has well repeatability and stability, and was used to determine the dopamine of urine. Under the optimized experiment conditions, the current response of the imprinted sensor was linear to the concentration of dopamine in the range of 1.0×10-7 ~ 1.0×10-5 mol/L, the linear equation was I (µA) = 7.9824+2.7210lgc (mol/L) with the detection limit of 3.3×10-8 mol/L. Conclusion: In this work, a highly efficient sensor for determination of DA was prepared with good sensitivity by GR and great selectivity of high special recognization ability by molecular imprinting membrane. This proposed sensor was used to determine the dopamine in human urine successfully.


2015 ◽  
Vol 11 (6) ◽  
pp. 710-721 ◽  
Author(s):  
Lili Li ◽  
Pui Mun Lee ◽  
Guocheng Yang ◽  
Erjia Liu

Sign in / Sign up

Export Citation Format

Share Document