The study on outdoor pedestrian thermal comfort in blocks: A case study of the Dao He Old Block in hot-summer and cold-winter area of southern China

Solar Energy ◽  
2019 ◽  
Vol 179 ◽  
pp. 210-225 ◽  
Author(s):  
Xuan Ma ◽  
Hiroatsu Fukuda ◽  
Dian Zhou ◽  
Weijun Gao ◽  
Mengying Wang
2021 ◽  
Vol 13 (8) ◽  
pp. 4563
Author(s):  
Nuno Baía Baía Saraiva ◽  
Luisa Dias Dias Pereira ◽  
Adélio Rodrigues Gaspar ◽  
José Joaquim da Costa

The adaptation of spaces to different usage typologies can be complex in heritage buildings. Facilities were initially planned for a specific type of use that, when changed, require additional measures to ensure a suitable indoor environment. Passive strategies—e.g., free cooling—are commonly used as an alternative without requiring equipment installation. However, its implementation often leads to unsatisfactory conditions. Therefore, it is important to clarify the main barriers to achieving thermal comfort in readapted historic buildings. The present work investigates the thermal comfort conditions reported by workers in office spaces of a historic building in the University of Coimbra. A monitoring campaign was carried out between May and September 2020 to assess indoor conditions’ quality. Due to the current pandemic of COVID-19, offices were not occupied at full capacity. A one-day evaluation of thermal comfort was made using a climate analyzer and six occupants were surveyed on 19 August 2020. The main results highlighted discomfort due to overheating of spaces. The causes were related to the combination of inadequate implementation of the free cooling actions and the building use. Furthermore, it was recommended the installation of HVAC systems in case of full capacity.


Buildings ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 232
Author(s):  
Juan Manuel Medina ◽  
Carolina M. Rodriguez ◽  
Maria Camila Coronado ◽  
Lina Maria Garcia

The analysis of thermal comfort in buildings, energy consumption, and occupant satisfaction is crucial to influencing the architectural design methodologies of the future. However, research in these fields in developing countries is sectorised. Most times, the standards to study and assess thermal comfort such as ASHRAE Standard 55, EN 15251, and ISO 7730 are insufficient and not appropriate for the geographical areas of application. This article presents a scoping review of published work in Colombia, as a representative case study, to highlight the state-of-the-art, research trends, gaps, and potential areas for further development. It examines the amount, origin, extent, and content of research and peer-reviewed documentation over the last decades. The findings allow new insights regarding the preferred models and the evaluation tools that have been used to date and that are recommended to use in the future. It also includes additional information regarding the most and least studied regions, cities, and climates in the country. This work could be of interest for the academic community and policymakers in the areas related to indoor and urban climate management and energy efficiency.


Energies ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2776
Author(s):  
Xin Ye ◽  
Jun Lu ◽  
Tao Zhang ◽  
Yupeng Wang ◽  
Hiroatsu Fukuda

Space cooling is currently the fastest-growing end-user in buildings. The global warming trend combined with increased population and economic development will lead to accelerated growth in space cooling in the future, especially in China. The hot summer and cold winter (HSCW) zone is the most densely populated and economically developed region in China, but with the worst indoor thermal environment. Relatively few studies have been conducted on the actual measurements in the optimization of insulation design under typical intermittent cooling modes in this region. This case study was conducted in Chengdu—the two residences selected were identical in design, but the south bedroom of the case study residence had interior insulation (inside insulation on all opaque interior surfaces of a space) retrofitted in the bedroom area in 2017. In August 2019, a comparative on-site measurement was done to investigate the effect of the retrofit work under three typical intermittent cooling patterns in the real-life scenario. The experimental result shows that interior insulation provides a significant improvement in energy-saving and the indoor thermal environment. The average energy savings in daily cooling energy consumption of the south bedroom is 42.09%, with the maximum reaching 48.91%. In the bedroom with interior insulation retrofit, the indoor temperature is closer to the set temperature and the vertical temperature difference is smaller during the cooling period; when the air conditioner is off, the room remains a comfortable temperature for a slightly longer time.