Suppression of reflected signals from substrate as clutters for cell measurements using acoustic impedance microscopy

Ultrasonics ◽  
2022 ◽  
Vol 118 ◽  
pp. 106580
Author(s):  
Ryo Nagaoka ◽  
Hideyuki Hasegawa ◽  
Kazuki Tamura ◽  
Sachiko Yoshida ◽  
Naohiro Hozumi ◽  
...  
Keyword(s):  
1978 ◽  
Vol 21 (2) ◽  
pp. 295-308
Author(s):  
Terry L. Wiley ◽  
Raymond S. Karlovich

Contralateral acoustic-reflex measurements were taken for 10 normal-hearing subjects using a pulsed broadband noise as the reflex-activating signal. Acoustic impedance was measured at selected times during the on (response maximum) and off (response minimum) portions of the pulsed activator over a 2-min interval as a function of activator period and duty cycle. Major findings were that response maxima increased as a function of time for longer duty cycles and that response minima increased as a function of time for all duty cycles. It is hypothesized that these findings are attributable to the recovery characteristics of the stapedius muscle. An explanation of portions of the results from previous temporary threshold shift experiments on the basis of acoustic-reflex dynamics is proposed.


2014 ◽  
Vol 33 (2) ◽  
pp. 163-168
Author(s):  
Xiujuan WANG ◽  
Jiliang WANG ◽  
Wei LI ◽  
Nittala Satyavani ◽  
Kalachand Sain

Acoustics ◽  
2020 ◽  
Vol 3 (1) ◽  
pp. 3-10
Author(s):  
Hideki Kumagai ◽  
Kazuto Kobayashi ◽  
Sachiko Yoshida ◽  
Koji Yokoyama ◽  
Norio Hirota ◽  
...  

Scanning acoustic microscopy reveals information on histology and acoustic impedance through tissues. The objective of the present study was to investigate whether acoustic impedance values in the liver over time reflect the progression of steatohepatitis through different grades and stages, and whether this approach can visualize histologic features of the disease. Mice were divided into two groups: a control group and a steatohepatitis group prepared by keeping the mice on a methionine and choline-deficient diet for 56 weeks. The hepatic lobe was excised for measurement of impedance and observation of microscopic structure using a commercially available scanning acoustic microscopy system with a central frequency of 320 MHz. Scanning acoustic microscopy revealed that acoustic impedance through liver tissue with steatohepatitis temporarily decreased with the degree of fat deposition and then increased in parallel with the progression of inflammation and fibrosis. However, the acoustic images obtained did not allow discrimination of detailed microstructures from those seen using light microscopy. In conclusion, estimation of acoustic impedance appears to have potential clinical applications, such as for monitoring or follow-up studies.


Metrology ◽  
2021 ◽  
Vol 1 (1) ◽  
pp. 17-38
Author(s):  
Nandeesh Hiremath ◽  
Vaibhav Kumar ◽  
Nicholas Motahari ◽  
Dhwanil Shukla

In order to progress in the area of aeroacoustics, experimental measurements are necessary. Not only are they required for engineering applications in acoustics and noise engineering, but also they are necessary for developing models of acoustic phenomenon around us. One measurement of particular importance is acoustic impedance. Acoustic Impedance is the measure of opposition of acoustical flow due to the acoustic pressure. It indicates how much sound pressure is generated by the vibration of molecules of a particular acoustic medium at a given frequency and can be a characteristic of the medium.The aim of the present paper is to give a synthetic overview of the literature on impedance measurements and to discuss the advantage and disadvantage of each measurement technique. In this work, we investigate the three main categories of impedance measurement techniques, namely reverberation chamber techniques, impedance tube techniques, and far-field techniques. Theoretical principles for each technique are provided along with a discussion on historical development and recent advancements for each technique.


Sign in / Sign up

Export Citation Format

Share Document