scholarly journals Detection of scene-irrelevant head movements via eye-head coordination information

2021 ◽  
Vol 3 (6) ◽  
pp. 501-514
Author(s):  
Xiaoxiong Fan ◽  
Yun Cai ◽  
Yufei Yang ◽  
Tianxing Xu ◽  
Yike Li ◽  
...  
Keyword(s):  
1999 ◽  
Vol 58 (3) ◽  
pp. 170-179 ◽  
Author(s):  
Barbara S. Muller ◽  
Pierre Bovet

Twelve blindfolded subjects localized two different pure tones, randomly played by eight sound sources in the horizontal plane. Either subjects could get information supplied by their pinnae (external ear) and their head movements or not. We found that pinnae, as well as head movements, had a marked influence on auditory localization performance with this type of sound. Effects of pinnae and head movements seemed to be additive; the absence of one or the other factor provoked the same loss of localization accuracy and even much the same error pattern. Head movement analysis showed that subjects turn their face towards the emitting sound source, except for sources exactly in the front or exactly in the rear, which are identified by turning the head to both sides. The head movement amplitude increased smoothly as the sound source moved from the anterior to the posterior quadrant.


2004 ◽  
Vol 35 (03) ◽  
Author(s):  
P Wagner ◽  
J Cunha ◽  
C Mauerer ◽  
C Vollmar ◽  
B Feddersen ◽  
...  
Keyword(s):  

2003 ◽  
Vol 10 (5) ◽  
pp. 862-869 ◽  
Author(s):  
A. W. Floris Vos ◽  
Matteus A. M. Linsen ◽  
J. Tim Marcus ◽  
Jos C. van den Berg ◽  
Jan Albert Vos ◽  
...  

2007 ◽  
Vol 29 (3) ◽  
pp. 205-212
Author(s):  
Junko Fukushima ◽  
Tadayoshi Asaka ◽  
Natsumi Ikeda ◽  
Yumi Ito

Author(s):  
F. Boehm ◽  
P. J. Schuler ◽  
R. Riepl ◽  
L. Schild ◽  
T. K. Hoffmann ◽  
...  

AbstractMicrovascular procedures require visual magnification of the surgical field, e.g. by a microscope. This can be accompanied by an unergonomic posture with musculoskeletal pain or long-term degenerative changes as the eye is bound to the ocular throughout the whole procedure. The presented study describes the advantages and drawbacks of a 3D exoscope camera system. The RoboticScope®-system (BHS Technologies®, Innsbruck, Austria) features a high-resolution 3D-camera that is placed over the surgical field and a head-mounted-display (HMD) that the camera pictures are transferred to. A motion sensor in the HMD allows for hands-free change of the exoscope position via head movements. For general evaluation of the system functions coronary artery anastomoses of ex-vivo pig hearts were performed. Second, the system was evaluated for anastomosis of a radial-forearm-free-flap in a clinical setting/in vivo. The system positioning was possible entirely hands-free using head movements. Camera control was intuitive; visualization of the operation site was adequate and independent from head or body position. Besides technical instructions of the providing company, there was no special surgical training of the surgeons or involved staff upfront performing the procedures necessary. An ergonomic assessment questionnaire showed a favorable ergonomic position in comparison to surgery with a microscope. The outcome of the operated patient was good. There were no intra- or postoperative complications. The exoscope facilitates a change of head and body position without losing focus of the operation site and an ergonomic working position. Repeated applications have to clarify if the system benefits in clinical routine.


2021 ◽  
Author(s):  
Valentin Holzwarth ◽  
Johannes Schneider ◽  
Joshua Handali ◽  
Joy Gisler ◽  
Christian Hirt ◽  
...  

AbstractInferring users’ perceptions of Virtual Environments (VEs) is essential for Virtual Reality (VR) research. Traditionally, this is achieved through assessing users’ affective states before and after being exposed to a VE, based on standardized, self-assessment questionnaires. The main disadvantage of questionnaires is their sequential administration, i.e., a user’s affective state is measured asynchronously to its generation within the VE. A synchronous measurement of users’ affective states would be highly favorable, e.g., in the context of adaptive systems. Drawing from nonverbal behavior research, we argue that behavioral measures could be a powerful approach to assess users’ affective states in VR. In this paper, we contribute by providing methods and measures evaluated in a user study involving 42 participants to assess a users’ affective states by measuring head movements during VR exposure. We show that head yaw significantly correlates with presence, mental and physical demand, perceived performance, and system usability. We also exploit the identified relationships for two practical tasks that are based on head yaw: (1) predicting a user’s affective state, and (2) detecting manipulated questionnaire answers, i.e., answers that are possibly non-truthful. We found that affective states can be predicted significantly better than a naive estimate for mental demand, physical demand, perceived performance, and usability. Further, manipulated or non-truthful answers can also be estimated significantly better than by a naive approach. These findings mark an initial step in the development of novel methods to assess user perception of VEs.


2021 ◽  
pp. 1-9
Author(s):  
Chiheon Kwon ◽  
Yunseo Ku ◽  
Shinhye Seo ◽  
Eunsook Jang ◽  
Hyoun-Joong Kong ◽  
...  

BACKGROUND: Low success and high recurrence of benign paroxysmal positional vertigo (BPPV) after home-based self-treated Epley and Barbeque (BBQ) roll maneuvers is an important issue. OBJECTIVE: To quantify the cause of low success rate of self-treated Epley and BBQ roll maneuvers and provide a clinically acceptable criterion to guide self-treatment head rotations. METHODS: Twenty-five participants without active BPPV wore a custom head-mount rotation monitoring device for objective measurements. Self-treatment and specialist-assisted maneuvers were compared for head rotation accuracy. Absolute differences between the head rotation evaluation criteria (American Academy of Otolaryngology guidelines) and measured rotation angles were considered as errors. Self-treatment and specialist-treated errors in maneuvers were compared. Between-trial variations and age effects were evaluated. RESULTS: A significantly large error and between-trial variation occurred in step 4 of the self-treated Epley maneuver, with a considerable error in the second trial. The cumulative error of all steps of self-treated BBQ roll maneuver was significantly large. Age effect occurred only in the self-treated BBQ roll maneuver. Errors in specialist-treated maneuvers ranged from 10 to 20 degrees. CONCLUSIONS: Real-time feedback of head movements during simultaneous head-body rotations could increase success rates of self-treatments. Specialist-treated maneuvers can be used as permissible rotation margin criteria.


Sign in / Sign up

Export Citation Format

Share Document