Preclinical Pharmacokinetics, Pharmacodynamics, Tissue Distribution, and Interspecies Scaling of Recombinant Human Coagulation Factor Xa I16L

2017 ◽  
Vol 106 (8) ◽  
pp. 2136-2143 ◽  
Author(s):  
Chuenlei Parng ◽  
Victoria Markiewicz ◽  
Jianqing Chen ◽  
Beth Leary ◽  
Nicole Duriga ◽  
...  
2008 ◽  
Vol 8 (3) ◽  
pp. 477-483 ◽  
Author(s):  
Yulia Vugmeyster ◽  
Pamela Szklut ◽  
Lioudmila Tchistiakova ◽  
William Abraham ◽  
Marion Kasaian ◽  
...  

1998 ◽  
Vol 79 (05) ◽  
pp. 1041-1047 ◽  
Author(s):  
Kathleen M. Donnelly ◽  
Michael E. Bromberg ◽  
Aaron Milstone ◽  
Jennifer Madison McNiff ◽  
Gordon Terwilliger ◽  
...  

SummaryWe evaluated the in vivo anti-metastatic activity of recombinant Ancylostoma caninum Anticoagulant Peptide (rAcAP), a potent (Ki = 265 pM) and specific active site inhibitor of human coagulation factor Xa originally isolated from bloodfeeding hookworms. Subcutaneous injection of SCID mice with rAcAP (0.01-0.2 mg/mouse) prior to tail vein injection of LOX human melanoma cells resulted in a dose dependent reduction in pulmonary metastases. In order to elucidate potential mechanisms of rAcAP’s anti-metastatic activity, experiments were carried out to identify specific interactions between factor Xa and LOX. Binding of biotinylated factor Xa to LOX monolayers was both specific and saturable (Kd = 15 nM). Competition experiments using antibodies to previously identified factor Xa binding proteins, including factor V/Va, effector cell protease receptor-1, and tissue factor pathway inhibitor failed to implicate any of these molecules as significant binding sites for Factor Xa. Functional prothrombinase activity was also supported by LOX, with a half maximal rate of thrombin generation detected at a factor Xa concentration of 2.4 nM. Additional competition experiments using an excess of either rAcAP or active site blocked factor Xa (EGR-Xa) revealed that most of the total factor Xa binding to LOX is mediated via interaction with the enzyme’s active site, predicting that the vast majority of cell-associated factor Xa does not participate directly in thrombin generation. In addition to establishing two distinct mechanisms of factor Xa binding to melanoma, these data raise the possibility that rAcAP’s antimetastatic effect in vivo might involve novel non-coagulant pathways, perhaps via inhibition of active-site mediated interactions between factor Xa and tumor cells.


1989 ◽  
Vol 61 (03) ◽  
pp. 437-441 ◽  
Author(s):  
Cindra Condra ◽  
Elka Nutt ◽  
Christopher J Petroski ◽  
Ellen Simpson ◽  
P A Friedman ◽  
...  

SummaryThe present work reports the discovery and charactenzation of an anticoagulant protein in the salivary gland of the giant bloodsucking leech, H. ghilianii, which is a specific and potent inhibitor of coagulation factor Xa. The inhibitor, purified to homogeneity, displayed subnanomolar inhibition of bovine factor Xa and had a molecular weight of approximately 15,000 as deduced by denaturing SDS-PAGE. The amino acid sequence of the first 43 residues of the H. ghilianii derived inhibitor displayed a striking homology to antistasin, the recently described subnanomolar inhibitor of factor Xa isolated from the Mexican leech, H. officinalis. Antisera prepared to antistasin cross-reacted with the H. ghilianii protein in Western Blot analysis. These data indicate that the giant Amazonian leech, H. ghilianii, and the smaller Mexican leech, H. officinalrs, have similar proteins which disrupt the normal hemostatic clotting mechanisms in their mammalian host’s blood.


1982 ◽  
Vol 47 (02) ◽  
pp. 096-100 ◽  
Author(s):  
K Mertens ◽  
R M Bertina

SummaryThe intrinsic activation of human factor X has been studied in a system consisting of purified factors and in plasma. In both these systems factor Xa stimulated the activation of factor X by factor IXa plus factor VIII This is due to the activation of factor VIII by factor Xa. When this factor Xa is formed via the extrinsic pathway, the extrinsic factor X activator functions as a stimulator of the intrinsic factor X activator.


2020 ◽  
Vol 27 ◽  
Author(s):  
Gabriela Bitencourt-Ferreira ◽  
Camila Rizzotto ◽  
Walter Filgueira de Azevedo Junior

Background: Analysis of atomic coordinates of protein-ligand complexes can provide three-dimensional data to generate computational models to evaluate binding affinity and thermodynamic state functions. Application of machine learning techniques can create models to assess protein-ligand potential energy and binding affinity. These methods show superior predictive performance when compared with classical scoring functions available in docking programs. Objective: Our purpose here is to review the development and application of the program SAnDReS. We describe the creation of machine learning models to assess the binding affinity of protein-ligand complexes. Method: SAnDReS implements machine learning methods available in the scikit-learn library. This program is available for download at https://github.com/azevedolab/sandres. SAnDReS uses crystallographic structures, binding, and thermodynamic data to create targeted scoring functions. Results: Recent applications of the program SAnDReS to drug targets such as Coagulation factor Xa, cyclin-dependent kinases, and HIV-1 protease were able to create targeted scoring functions to predict inhibition of these proteins. These targeted models outperform classical scoring functions. Conclusion: Here, we reviewed the development of machine learning scoring functions to predict binding affinity through the application of the program SAnDReS. Our studies show the superior predictive performance of the SAnDReS-developed models when compared with classical scoring functions available in the programs such as AutoDock4, Molegro Virtual Docker, and AutoDock Vina.


1989 ◽  
Vol 263 (1) ◽  
pp. 187-194 ◽  
Author(s):  
A Leyte ◽  
K Mertens ◽  
B Distel ◽  
R F Evers ◽  
M J M De Keyzer-Nellen ◽  
...  

The epitopes of four monoclonal antibodies against coagulation Factor VIII were mapped with the use of recombinant DNA techniques. Full-length Factor VIII cDNA and parts thereof were inserted into the vector pSP64, permitting transcription in vitro with the use of a promoter specific for SP6 RNA polymerase. Factor VIII DNA inserts were truncated from their 3′-ends by selective restriction-enzyme digestion and used as templates for ‘run-off’ mRNA synthesis. Translation in vitro with rabbit reticulocyte lysate provided defined radiolabelled Factor VIII fragments for immunoprecipitation studies. Two antibodies are shown to be directed against epitopes on the 90 kDa chain of Factor VIII, between residues 712 and 741. The 80 kDa chain appeared to contain the epitopes of the other two antibodies, within the sequences 1649-1778 and 1779-1840 respectively. The effect of antibody binding to these sequences was evaluated at two distinct levels within the coagulation cascade. Both Factor VIII procoagulant activity and Factor VIII cofactor function in Factor Xa generation were neutralized upon binding to the region 1779-1840. The antibodies recognizing the region 713-740 or 1649-1778, though interfering with Factor VIII procoagulant activity, did not inhibit in Factor Xa generation. These findings demonstrate that antibodies that virtually inhibit Factor VIII in coagulation in vitro are not necessarily directed against epitopes involved in Factor VIII cofactor function. Inhibition of procoagulant activity rather than of cofactor function itself may be explained by interference in proteolytic activation of Factor VIII. This hypothesis is in agreement with the localization of the epitopes in the proximity of thrombin-cleavage or Factor Xa-cleavage sites.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M.M Engelen ◽  
C Van Laer ◽  
M Jacquemin ◽  
C Vandenbriele ◽  
K Peerlinck ◽  
...  

Abstract Introduction Contact of blood with artificial surfaces such as mechanical support devices, catheters, and mechanical heart valves activates the contact activation (CA) pathway of coagulation. Furthermore, recent animal data and clinical studies suggest a more important contribution of CA in pathological thrombus formation in other cardiovascular diseases. Direct oral anticoagulants (DOACs) are recommended as first-line treatment in most patients who require long-term anticoagulation. However, because DOACs directly inhibit a single downstream coagulation factor (thrombin (fXIIa) or factor Xa (fXa)), it has been suggested that their efficacy could be reduced in the presence of strong activation of the CA pathway as compared to anticoagulants that target multiple, more upstream located coagulation factors. Purpose To compare the efficacy of a DOAC (apixaban) and heparin to suppress thrombin generation in the presence of strong CA pathway activation. Methods Pooled platelet-poor plasma was spiked with either apixaban (dissolved in DMSO and PBS) or unfractionated heparin to achieve therapeutic plasma levels. SynthASil, a commercially available mixture of phospholipids and silica, was used to stimulate the CA pathway in two different dilutions (1–80 and 5–80). Downstream coagulation was accessed by Thrombin Generation Test using Thrombinoscope by Stago and associated Thrombin Calibrator (activity 640 nM). The endogenous thrombin potential (area under the thrombin generation curve; ETP), peak thrombin generation (PTG), time to peak (ttPeak) and time to start (ttStart) were accessed. Results With decreasing concentrations of apixaban, stimulation with the lower dose SynthASil reveals an increasing ETP and PTG. As expected, ttPeak and ttStart decreased. Even supratherapeutic levels of apixaban (i.e. 1120 ng/mL) could not inhibit thrombin from being generated, in striking contrast with UFH where no thrombin was formed. Using a five times higher dose of SynthASil showed comparable ETP for all concentrations of apixaban, allocated around the control value. PTG, however, slightly increased with decreasing concentrations of apixaban. ttPeak and ttStart slightly decreased. Except for the subtherapeutic UFH concentration of 0,114 IU/mL, no thrombin was generated with UFH. Conclusion UFH is more effective in inhibiting downstream thrombin generation compared to apixaban as a response to activation of the CA pathway in vitro. These findings could help explain why direct inhibitors were not able to show non-inferiority in patients with mechanical heart valves and support the development of specific CA pathway inhibitors for patients with conditions that activate the CA pathway. Thrombin generation curves Funding Acknowledgement Type of funding source: None


Sign in / Sign up

Export Citation Format

Share Document