scholarly journals Tissue transglutaminase autoantibody enzyme-linked immunosorbent assay in detecting celiac disease

1998 ◽  
Vol 115 (6) ◽  
pp. 1322-1328 ◽  
Author(s):  
Satu Sulkanen ◽  
Tuula Halttunen ◽  
Kaija Laurila ◽  
Kaija-Leena Kolho ◽  
Ilma R. Korponay-Szabó ◽  
...  
1998 ◽  
Vol 114 ◽  
pp. A420 ◽  
Author(s):  
S. Sulkanen ◽  
T. Halttunen ◽  
I. Korponay-Szabo ◽  
K. Laurila ◽  
P. Collin ◽  
...  

2006 ◽  
Vol 13 (1) ◽  
pp. 150-151 ◽  
Author(s):  
Harry E. Prince

ABSTRACT New assays for antibodies to deamidated gliadin peptides (DGP) expressing celiac disease-specific epitopes were evaluated using 154 sera previously tested for endomysial immunoglobulin A (IgA) (EMA), transglutaminase IgA (TGA), and conventional gliadin antibodies. DGP antibody results showed 97% concordance with EMA and TGA results. Of 56 sera negative for EMA and TGA but positive for conventional gliadin antibodies, 54 (96%) were negative for DGP antibodies.


2011 ◽  
Vol 26 (6) ◽  
pp. 695-699 ◽  
Author(s):  
Charalampos Agakidis ◽  
Thomais Karagiozoglou-Lampoudi ◽  
Marina Kalaitsidou ◽  
Theodoros Papadopoulos ◽  
Afroditi Savvidou ◽  
...  

Author(s):  
Karsten Conrad ◽  
Dirk Roggenbuck ◽  
Annelore Ittenson ◽  
Dirk Reinhold ◽  
Thomas Buettner ◽  
...  

AbstractThis study investigated whether a dot immunoassay (DIA) can provide simultaneous detection of anti-tissue transglutaminase (tTG), anti-deamidated gliadin (DG) and total IgA antibodies, as required in the work-up of celiac disease (CD) patients.Celiac disease patients (n=111) consecutively diagnosed from 2001 to 2011 at the Children’s Hospital and Institute of Immunology (Technical University Dresden) were tested for anti-tTG, anti-DG and total IgA by enzyme-linked immunosorbent assay (ELISA) and DIA retrospectively. Blood donors (n=45) and non-CD individuals with low IgA serum levels (n=8) were included as controls. Antibodies to endomysial antigens (EmA) were assessed by indirect immunofluorescence (IIF).Four (3.6%) of 111 CD patients demonstrated an IgA deficiency with total IgA below 50 mg/L by ELISA. Total IgA of the 107 IgA-non-deficient CD patients varied from 70 to 6000 mg/L. All four IgA-deficient CD patients were detected by a reduced reaction control of DIA and demonstrated positive anti-tTG or anti-DG IgG by DIA or ELISA. Detection of anti-tTG and anti-DG by DIA and ELISA showed a very good agreement (IgA: κ=0.972, 0.856, respectively; IgG: 0.921, 0.895, respectively).Immunodot assay is a reliable and easy-to-use technique for the detection of IgA-deficient CD patients. Simultaneous assessment of anti-tTG and anti-DG IgA antibodies, and IgA deficiency by DIA can improve the efficacy of CD serology.


2009 ◽  
Vol 16 (11) ◽  
pp. 1576-1582 ◽  
Author(s):  
Miriam Parizade ◽  
Yoram Bujanover ◽  
Batya Weiss ◽  
Vered Nachmias ◽  
Bracha Shainberg

ABSTRACT Diagnosis of celiac disease frequently depends upon serology assays. We set out to prospectively assess the diagnostic value of five serology tests: an enzyme-linked immunosorbent assay (ELISA) for tissue transglutaminase (tTG)-immunoglobulin A (IgA) and tTG-IgG, a chemiluminescence assay for tTG-IgA, an ELISA for deamidated gliadin peptide (DGP) IgG and IgA screening, and detection of endomysial antibodies (Abs) by indirect immunofluorescence. One hundred sixteen children at high risk for developing celiac disease were evaluated clinically and underwent small bowel biopsies and blood serology tests. We examined differences between younger and older children in terms of clinical presentation, test performance, and the ability of high Ab levels to correctly predict diagnosis of celiac disease. Celiac disease was diagnosed for 85 (73%) children. No significant clinical differences were observed between the biopsy-positive and biopsy-negative groups. Children ≤3 years of age revealed higher concentrations of tTG-IgA and DGP Abs than children >3 years old (P = 0.017 and 0.007, respectively). High Ab concentrations were predictive of villous atrophies, with sensitivities ranging from 92.8% to 97.9%, depending on the assay and the cutoff points applied. Sensitivities, specificities, positive predictive values, and negative predictive values varied among assays and improved after correction for best cutoff points. Assay specificities obtained in the clinical setting were lower than expected. The new tTG-IgA chemiluminescence assay demonstrated high throughput but low specificity (74.2%). The tTG-IgA ELISA exhibited the highest test efficiency, and the tTG-IgA chemiluminescence assay was suitable for large-scale screening, with reduced specificity. High concentrations of celiac disease-specific Abs bring into question the need for performance of biopsies on children at high risk.


1988 ◽  
Vol 113 (2) ◽  
pp. 286-289 ◽  
Author(s):  
Neil T. Tucker ◽  
Fikry S. Barghuthy ◽  
Thomas J. Prihoda ◽  
Vijay Kumar ◽  
Aaron Lerner ◽  
...  

2021 ◽  
Vol 8 ◽  
Author(s):  
Diyora Abdukhakimova ◽  
Kuanysh Dossybayeva ◽  
Anna Grechka ◽  
Zhaina Almukhamedova ◽  
Alyona Boltanova ◽  
...  

Background and Objective: The diagnosis of Celiac Disease (CD) is first based on the positivity for specific serological markers. The CytoBead CeliAK immunoassay simultaneously measures antibodies (IgA) directed to tissue transglutaminase (tTG), endomysium (EMA), and deamidated gliadin (DG), in addition to providing a control for total IgA levels. The aim of this study is to assess the reliability of this multiplex assay to detect anti-tTG IgA positive patients, compared with a conventional single-parameter enzyme-linked immunosorbent assay (ELISA).Methods: Serum samples from 149 pediatric patients were assessed by both CytoBead CeliAK immunoassay and ELISA, in order to evaluate their concordance for the measurement of anti-tTG IgA.Results: The measurement of anti-tTG IgA by CytoBead CeliAK immunoassay basically showed a complete concordance rate with the conventional and single-parameter ELISA, according to the respective cutoff values (3 U/ml and 10 U/ml).Conclusions: Our comparative analysis demonstrates a substantial equivalency between multiplex CytoBead CeliAK assay and the single-parameter conventional ELISA to assess anti-tTG IgA antibody in the context of the screening for CD in children. Importantly, CytoBead CeliAK assay could present some preanalytic, analytic, and economic advantages.


Sign in / Sign up

Export Citation Format

Share Document