Epidermal in vivo and in vitro studies by attenuated total reflection mid-infrared spectroscopy using flexible silver halide fibre-probes

2003 ◽  
Vol 651-653 ◽  
pp. 127-132 ◽  
Author(s):  
H.M. Heise ◽  
L. Küpper ◽  
W. Pittermann ◽  
M. Stücker
Sensors ◽  
2019 ◽  
Vol 19 (23) ◽  
pp. 5130 ◽  
Author(s):  
Ine L. Jernelv ◽  
Karina Strøm ◽  
Dag Roar Hjelme ◽  
Astrid Aksnes

The development of rapid and accurate biomedical laser spectroscopy systems in the mid-infrared has been enabled by the commercial availability of external-cavity quantum cascade lasers (EC-QCLs). EC-QCLs are a preferable alternative to benchtop instruments such as Fourier transform infrared spectrometers for sensor development as they are small and have high spectral power density. They also allow for the investigation of multiple analytes due to their broad tuneability and through the use of multivariate analysis. This article presents an in vitro investigation with two fiber-coupled measurement setups based on attenuated total reflection spectroscopy and direct transmission spectroscopy for sensing. A pulsed EC-QCL (1200–900 cm − 1 ) was used for measurements of glucose and albumin in aqueous solutions, with lactate and urea as interferents. This analyte composition was chosen as an example of a complex aqueous solution with relevance for biomedical sensors. Glucose concentrations were determined in both setup types with root-mean-square error of cross-validation (RMSECV) of less than 20 mg/dL using partial least-squares (PLS) regression. These results demonstrate accurate analyte measurements, and are promising for further development of fiber-coupled, miniaturised in vivo sensors based on mid-infrared spectroscopy.


2015 ◽  
Vol 87 (4) ◽  
pp. 2314-2320 ◽  
Author(s):  
Cosima Koch ◽  
Markus Brandstetter ◽  
Patrick Wechselberger ◽  
Bettina Lorantfy ◽  
Maria Reyes Plata ◽  
...  

2017 ◽  
Vol 89 (10) ◽  
pp. 5285-5293 ◽  
Author(s):  
Aazam Khoshmanesh ◽  
Dale Christensen ◽  
David Perez-Guaita ◽  
Inaki Iturbe-Ormaetxe ◽  
Scott L. O’Neill ◽  
...  

The Analyst ◽  
2018 ◽  
Vol 143 (13) ◽  
pp. 3156-3163 ◽  
Author(s):  
Maria Paraskevaidi ◽  
Camilo L. M. Morais ◽  
Kássio M. G. Lima ◽  
Katherine M. Ashton ◽  
Helen F. Stringfellow ◽  
...  

Attenuated total reflection FTIR (ATR-FTIR) spectroscopy has been combined with chemometrics to detect women with endometrial and ovarian carcinomas using non-invasively collected urine samples.


2006 ◽  
Vol 12 (1) ◽  
pp. 18-23 ◽  
Author(s):  
A. Ring ◽  
V. Schreiner ◽  
H. Wenck ◽  
K. P. Wittern ◽  
L. Kupper ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document