Effect of interactions between voltage and current harmonics on the net harmonic current produced by single phase non-linear loads

1997 ◽  
Vol 40 (3) ◽  
pp. 155-160 ◽  
Author(s):  
E.F. El-Saadany ◽  
M.M.A. Salama
2018 ◽  
Vol 197 ◽  
pp. 11023
Author(s):  
I Made Wiwit Kastawan

Almost all today electrical loads are considered non-linear such as switch mode power supply (SMPS) for powering computer and mobile phone or variable speed drive (VSD) for driving home and industrial electric motors. These loads generate ac non-sinusoidal current containing a lot of harmonics as indicated by its high total harmonics distortion (THD) figure. Current harmonics bring negative effects into all electrical power system components, including three-phase generator. This paper provides analysis of load current harmonics effects on vibration of three-phase generator. Three different laboratory experiments have been conducted i.e. three-phase linear resistive loading, non-linear loading with a three-phase ac/dc converter and non-linear loading with three single-phase capacitor filtered ac/dc converters. Results show that the higher load current harmonics content the higher is vibration of the three-phase generator. Non-linear loading with a three-phase ac/dc converter that generate about 24.7% THD gives an increase of 4.3% and 5.5% in average of vertical and horizontal vibrations of the three-phase generator respectively. Further, non-linear loading with three single-phase capacitor filtered ac/dc converters that generate THD as high as 74.9% gives significant increase of 28.1% and 23.6% in average of vertical and horizontal vibrations respectively.


2018 ◽  
Author(s):  
Asnil

One of the problems of electricity quality is harmonics. Harmonic is one ofthe components sinusoidal from one period wave that has the frequency representingmultiple from the fundamental component. Voltage and current distortion caused bynon-linear loads. One of kinds of non-linear loads is Inverter. Harmonic is verydisturbs and harm when exceeding standard limit that appointed. Standard worn asreference in this research is standard IEEE 519-1992, used to voltage limit andmaximum harmonic current.


2016 ◽  
Vol 78 (10-4) ◽  
Author(s):  
Amirullah Amirullah ◽  
Mochamad Ashari ◽  
Ontoseno Penangsan ◽  
Adi Soeprijanto

Randomly installed distributed generators (DGs) in households may cause unbalanced line current in a distribution network. This research presents a battery energy system for balancing of line current in a distribution network involving multi units of single phase photovoltaic (PV) distributed generators (DGs). In this paper, the PV generators were simulated consisting of a buck-boost DC/DC converter and single phase DC/AC inverter. It was connected to the distribution line through the low voltage 220 volt 50 Hz. The proposed phase balancing system uses battery energy storage and three single phase bidirectional inverters. The inverter is capable of injecting current or absorbing power from the line to the battery. This inverter operation is arranged to balance each distribution line separately, as well as to improve other power quality parameters, such as voltage and current harmonics. Simulation results show that the system was capable of improving the unbalanced line current from 15.59 % to 11, 48 % and unbalanced line voltage from 1.76 % to 0.58 %. The system was able for increasing current harmonics from 0.98 % to 1.03% and voltage harmonics from 38.96% to 39.08%.


This study investigated current harmonic distortions emanating from domestic non-linear loads which have adverse deleterious effects on installed low voltage switchgears such as transformers and conductors. The study examined harmonic distortions emanating from dominant domestic nonlinear loads such as microwave, TV set, radio, fridge, video player and compacted fluorescence bulbs (CFLs) using a power quality equipment. From the results obtained, it was noted that there is need to mitigate harmonic distortions generated by domestic loads at point of common coupling (PCC). It is pertinent to mention that the recent study on supplied loads carried out in Kenya power grid shows that above 67% of power end users are domestic consumers. Under current last mile initiative and Global Partnership on Output Based Aid (GPOBA), unprecedented increase of domestic loads connected to the power grid is predicted. It is worth pointing out that most of these domestic loads have switch mode power supplies (SMPS) which have inherent characteristics of distorting current waveform which causes voltage distortions, over-heating of neutral conductors and premature failure of distribution transformers. Further, most of these loads have two modes; standby/sleep mode and operating mode. Results shows that the two modes generate current harmonic distortions which stream back to power utility network through the service cable. Recently, engineers have designed electronic devices that consume less power. These devices draw current in pulses rather than sinusoidal waveform. As a result, the quality of power supplies continues to deteriorate hence adversely affecting the installed low voltage switchgears such as distribution transformers. Although various mitigation measures exist to reduce the effects of harmonic distortions, this paper proposes a single phase active filter as an optimal solution for attenuating the harmonics emanating from domestic non-linear loads.