Multiple internal reflection FT-IR spectroscopy (MIRFTIRS) study of the electrochemical synthesis and redox process of poly (1,5-diaminonaphthalene)

1998 ◽  
Vol 93 (2) ◽  
pp. 89-96 ◽  
Author(s):  
Minh-Chau Pham ◽  
Mohamed Oulahyne ◽  
Malik Mostefai ◽  
Mohamed Mehdi Chehimi
2001 ◽  
Vol 55 (10) ◽  
pp. 1352-1359 ◽  
Author(s):  
Sanong Ekgasit ◽  
Adchara Padermshoke

Optical contact between an internal reflection element (IRE) and a sample is crucial for obtaining a good spectrum in an attenuated total reflection (ATR) experiment. When an air gap is present between the IRE and the sample, the spectrum severely deteriorates. Two techniques for determining the goodness of contact are proposed—first, by making a comparison between polarized ATR spectra and, second, by making a comparison between ATR and transmission spectra. When the optical contact is achieved, the normalized p-polarized ATR spectrum is exactly the same as the normalized s-polarized ATR spectrum. Moreover, the ratio between the normalized absorbance measured in the ATR mode and the normalized absorbance measured in the transmission mode equals the ratio between the frequency being considered and the normalization frequency. Theoretical and experimental investigations have been performed in order to verify the proposed techniques.


Author(s):  
Maciej Strzempek ◽  
Karolina A. Tarach ◽  
Kinga Góra-Marek ◽  
Fernando Rey ◽  
Miguel Palomino ◽  
...  

Abstract In this article the results of the statistical MC modelling corroborated by the FT-IR spectroscopy and gravimetric adsorption studies of the low aliphatic hydrocarbons in ZSM-5 (Si/Al =28 or...


2021 ◽  
Vol 22 (4) ◽  
pp. 2191
Author(s):  
Jing Huang ◽  
Nairveen Ali ◽  
Elsie Quansah ◽  
Shuxia Guo ◽  
Michel Noutsias ◽  
...  

In recent decades, vibrational spectroscopic methods such as Raman and FT-IR spectroscopy are widely applied to investigate plasma and serum samples. These methods are combined with drop coating deposition techniques to pre-concentrate the biomolecules in the dried droplet to improve the detected vibrational signal. However, most often encountered challenge is the inhomogeneous redistribution of biomolecules due to the coffee-ring effect. In this study, the variation in biomolecule distribution within the dried-sample droplet has been investigated using Raman and FT-IR spectroscopy and fluorescence lifetime imaging method. The plasma-sample from healthy donors were investigated to show the spectral differences between the inner and outer-ring region of the dried-sample droplet. Further, the preferred location of deposition of the most abundant protein albumin in the blood during the drying process of the plasma has been illustrated by using deuterated albumin. Subsequently, two patients with different cardiac-related diseases were investigated exemplarily to illustrate the variation in the pattern of plasma and serum biomolecule distribution during the drying process and its impact on patient-stratification. The study shows that a uniform sampling position of the droplet, both at the inner and the outer ring, is necessary for thorough clinical characterization of the patient’s plasma and serum sample using vibrational spectroscopy.


1989 ◽  
Author(s):  
Ning Xi ◽  
Shifu Weng ◽  
Jinguang Wu ◽  
Guangxian Xu

2020 ◽  
Author(s):  
Milena Pavlíková ◽  
Lenka Scheinherrová ◽  
Martina Záleská ◽  
Zbyšek Pavlík

Sign in / Sign up

Export Citation Format

Share Document