scholarly journals PREVALENCE OF CORONARY ARTERY DISEASE DETECTED ON ROUTINE ECG-GATED COMPUTED TOMOGRAPHY EVALUATION OF CONGENITAL THORACIC AORTIC ANEURYSMS

2011 ◽  
Vol 57 (14) ◽  
pp. E1530
Author(s):  
Chris J. Rowan ◽  
Lee M. Mitsumori ◽  
James H. Caldwell ◽  
William P. Shuman ◽  
Joshua L. Busch ◽  
...  
2015 ◽  
Vol 30 (9) ◽  
pp. 701-706 ◽  
Author(s):  
Bijoy G. Rajbanshi ◽  
Paris Charilaou ◽  
Bulat A. Ziganshin ◽  
Chanaka Rajakaruna ◽  
Tranquilli Maryann ◽  
...  

2010 ◽  
Vol 6 (2) ◽  
pp. 43 ◽  
Author(s):  
Andreas H Mahnken ◽  

Over the last decade, cardiac computed tomography (CT) technology has experienced revolutionary changes and gained broad clinical acceptance in the work-up of patients suffering from coronary artery disease (CAD). Since cardiac multidetector-row CT (MDCT) was introduced in 1998, acquisition time, number of detector rows and spatial and temporal resolution have improved tremendously. Current developments in cardiac CT are focusing on low-dose cardiac scanning at ultra-high temporal resolution. Technically, there are two major approaches to achieving these goals: rapid data acquisition using dual-source CT scanners with high temporal resolution or volumetric data acquisition with 256/320-slice CT scanners. While each approach has specific advantages and disadvantages, both technologies foster the extension of cardiac MDCT beyond morphological imaging towards the functional assessment of CAD. This article examines current trends in the development of cardiac MDCT.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Michael Hammer ◽  
Muhtashim Mian ◽  
Levi Elhadad ◽  
Mary Li ◽  
Idan Roifman

Abstract Background Appropriate use criteria (AUC) have been developed in response to growth in cardiac imaging utilization and concern regarding associated costs. Cardiac computed tomography angiography (CCTA) has emerged as an important modality in the evaluation of coronary artery disease, however its appropriate utilization in actual practice is uncertain. Our objective was to determine the appropriate utilization of CCTA in a large quaternary care institution and to compare appropriate utilization pre and post publication of the 2013 AUC guidelines. We hypothesized that the proportion of appropriate CCTA utilization will be similar to those of other comparable cardiac imaging modalities and that there would be a significant increase in appropriate use post AUC publication. Methods We employed a retrospective cohort study design of 2577 consecutive patients undergoing CCTA between January 1, 2012 and December 30, 2016. An appropriateness category was assigned for each CCTA. Appropriateness classifications were compared pre- and post- AUC publication via the chi-square test. Results Overall, 83.5% of CCTAs were deemed to be appropriate based on the AUC. Before the AUC publication, 75.0% of CCTAs were classified as appropriate whereas after the AUC publication, 88.0% were classified as appropriate (p < 0.001). The increase in appropriate utilization, when extrapolated to the Medicare population of the United States, was associated with potential cost savings of approximately $57 million per year. Conclusions We report a high rate of appropriate use of CCTA and a significant increase in the proportion of CCTAs classified as appropriate after the AUC publication.


Author(s):  
Po-Yi Li ◽  
Ru-Yih Chen ◽  
Fu-Zong Wu ◽  
Guang-Yuan Mar ◽  
Ming-Ting Wu ◽  
...  

The objective of this study was to determine how coronary computed tomography angiography (CCTA) can be employed to detect coronary artery disease in hospital employees, enabling early treatment and minimizing damage. All employees of our hospital were assessed using the Framingham Risk Score. Those with a 10-year risk of myocardial infarction or death of >10% were offered CCTA; the Coronary Artery Disease Reporting and Data System (CAD-RADS) score was the outcome. A total of 3923 hospital employees were included, and the number who had received CCTA was 309. Among these 309, 31 (10.0%) had a CAD-RADS score of 3–5, with 10 of the 31 (32.3%) requiring further cardiac catheterization; 161 (52.1%) had a score of 1–2; and 117 (37.9%) had a score of 0. In the multivariate logistic regression, only age of ≥ 55 years (p < 0.05), hypertension (p < 0.05), and hyperlipidemia (p < 0.05) were discovered to be significant risk factors for a CAD-RADS score of 3–5. Thus, regular and adequate control of chronic diseases is critical for patients, and more studies are required to be confirmed if there are more significant risk factors.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M Sabet ◽  
S Elkaffas ◽  
S.W.G Bakhoum ◽  
H Kandil

Abstract Introduction Smoking and obesity are recognized as important modifiable risk factors for coronary artery disease (CAD). However, the general perception that smoking protects against obesity is a common reason for starting, and/or not quitting smoking. Purpose To detect the quantity, quality and relative distribution of subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) estimated by abdominal computed tomography in smokers versus non- smokers. Methods The abdominal muscular wall was traced manually to calculate SAT and VAT areas (cm2) (outside and inside abdominal muscular wall respectively) as well as SAT density [Hounsfield units (HU)] at L4-L5 in 409 consecutive patients referred for evaluation of chest pain by multi-slice computed tomography coronary angiography (MSCT-CA). Results 26% of the studied patients (n=107) were current smokers, while the remaining 74% (n=302) never smoked. Coronary artery atherosclerosis was more prevalent in smokers compared to non-smokers (64.5% vs 55.0%; p=0.09). Smokers had statistically significantly lower body mass index (BMI) (31.2±4.3 vs. 32.5±4.7 kg/m2; p=0.015), hip circumference (HC) (98.6±22.5 vs. 103.9±20.9 cm; p=0.031), total fat area (441.62±166.34 vs. 517.95±169.51cm2; p&lt;0.001), and SAT area (313.07±125.54 vs. 390.93±143.28 cm2; p&lt;0.001) as compared to non-smokers. However, smokers had statistically significantly greater waist-to-hip ratio (0.98±0.08 vs. 0.96±0.08; p=0.010), VAT/SAT area ratio (0.41±0.23 vs. 0.35±0.20; p=0.013), and denser SAT depot (−98.91±7.71 vs. −102.08±6.44 HU; p&lt;0.001). Conclusion Smoking contributes to CAD and to the pathogenic redistribution of body fat towards VAT, through limiting SAT potential to expand. Funding Acknowledgement Type of funding source: None


Sign in / Sign up

Export Citation Format

Share Document