scholarly journals The new adjustable artificial sphincter victo: Surgical technique and results after a follow-up of more than one year

2020 ◽  
Vol 19 ◽  
pp. e2379
Author(s):  
G. Ameli ◽  
P. Weibl ◽  
M. Rutkowski ◽  
W.A. Hübner
2021 ◽  
Vol 39 ◽  
Author(s):  
Robert Marchand ◽  
◽  
Laura Scholl ◽  
Manoshi Bhowmik-Stoker ◽  
Kelly Taylor ◽  
...  

Introduction: Valgus knee deformities can sometimes be challenging to address during total knee arthroplasties (TKAs). While appropriate surgical technique is often debated, the role of new operative technologies in addressing these complex cases has not been clearly established. The purpose of this study was to analyze the usefulness of computed tomography scan (CT)-based three-dimensional (3D) modeling operative technology in assisting with TKA planning, execution of bone cuts, and alignment. Specifically, we evaluated valgus TKAs performed using this CT-based technology for: (1) intraoperative implant plan, number of releases, and surgeon prediction of component size; (2) survivorship and clinical outcomes at a minimum follow up of one year; and (3) radiographic outcomes. Materials and Methods: A total of 152 patients who had valgus deformities receiving a CT-based TKA performed by a single surgeon were analyzed. Cases were performed using an enhanced preoperative planning and real-time intraoperative feedback and cutting tool. The surgeon predicted and recorded implant sizes preoperatively and all patients received implants with initial and final implant alignment, flexion/extension gaps, and full or partial soft tissue releases recorded. A modified Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS, JR.) scores were collected preoperatively and at approximately six months and one year postoperatively. Preoperative coronal alignment ranged from 1 to 13° valgus. Follow-up radiographs were also evaluated for alignments, loosenings, and/or progressive radiolucencies. Results: A total of 96% of cases were corrected to within 3° of mechanical neutral. For outlier cases, initial deformities ranged from valgus 5 to 13°, with final alignment ranging from 4 to 8° valgus (mean 4° correction). Patients had mean femoral internal rotation of 2° and mean femoral flexion of 4°. The surgeon was within one size on the femur and tibia 94 and 100% of the time, respectively. Only one patient required a lateral soft tissue release and one patient had osteophytes removed, which required a medial soft tissue release. Five patients required manipulations under anesthesia. Aside from these, there were no postoperative medical and/or surgical complications and there was 100% survivorship at final follow up. WOMAC and KOOS, JR. scores improved significantly from a mean of 21 ± 9 and 48 ± 10 points preoperatively to 4 ± 6 (p<0.05) and 82 ± 15 (p<0.05) at final follow up, respectively. None of the cases exhibited progressive radiolucencies by final follow up. Discussion: A limitation of this study was not evaluating dynamic kinematics in these patients to determine if rotation had any effects on kinematics. Future studies will evaluate this concern. Nevertheless, the technology successfully assisted with planning, executing bone cuts, and achieving alignment in TKAs complicated by the deformity. This may allow surgeons to predictably avoid soft tissue releases and accurately know component sizes preoperatively, while consistently achieving desired postoperative alignment. Conclusions: This study demonstrated the utility of CT-based 3D modeling techniques for challenging valgus deformity cases. Use of 3D modeling allowed the TKA components to be positioned according to the patient’s anatomy in the coronal, transverse, and sagittal planes. When making these intraoperative implant adjustments, the surgeon may choose to place components outside the preoperative planning guidelines based on the clinical needs of the patient.


2016 ◽  
Vol 49 (02) ◽  
pp. 172-177 ◽  
Author(s):  
Roberto Moltó-García ◽  
María Eloísa Villaverde-Doménech ◽  
Virina González-Alonso ◽  
Francisco Ripoll-Orts ◽  
Eduardo Simon-Sanz

ABSTRACTBackground: Periareolar augmentation mastopexy is one of the most demanded operations at Plastic Surgery clinics. Nevertheless, it is one of the leads of malpractice claims in United States caused by the high patient expectations and the standard surgical techniques which may result in common complications. The aim of this report is to present a new surgical approach to solve these complications. Methods: After establishing a working hypothesis, we performed a revision study of our patients and we came to the following conclusion: in order to perform a periareolar mastopexy for ptosis correction, breast has to be tuberous at any level and to have abnormally short inferior pole. These findings may explain the main complications from periareolar augmentation mastopexy with the standard surgical techniques. Consequently, we started a prospective observational study including 56 patients following a new surgical technique which deals the cases as tuberous breasts. Results: During three years, fifty-six periareolar mastopexies were performed with this new surgical approach with one year follow-up. No major complications were observed and 40 of the patients (71%) described the results as very positive. Conclusion: “If a periareolar mastopexy can be performed, then it must be a tuberous breast”. According to this, a new surgical technique for periareolar augmentation mastopexy has been developed obtaining an improvement in our surgical results and achieving a totally different view on this pathology, which has not been reported in literature yet.


2020 ◽  
Vol 10 (18) ◽  
pp. 6508
Author(s):  
Raffaele Rauso ◽  
Giorgio Lo Giudice ◽  
Carmelo Lo Faro ◽  
Giovanni Francesco Nicoletti ◽  
Romolo Fragola ◽  
...  

In this paper, we present a simple way to place the implant into a harvested pocket and to subsequently fix it percutaneously. Eighteen patients (1 male, 13 females, 4 transgender), underwent facial implant placement; a total of 31 implants were placed (1 pair of angles of the mandible implants, 12 pairs of malar/sub-malar implants, and 5 chin implants). The intraoral approach was performed on 15 patients, and on the remaining three patients, the sub-ciliary lower lid approach was preferred. Patients were followed up for at least one year with a maximum follow-up of seven years (mean 1.8 years). In all the cases, except one, patients healed without complications. One case of implant displacement and infection was recorded. No other complication was documented. The technique described is similar to the one suggested by Peled, although some useful tips were added, namely the use of sutures, not only to fix the implant but also to drive it into the harvested pocket. In addition, larger absorbable “left in place” sutures were used, avoiding accidental implant dislocation during their removal. Further studies are required to gain a more complete understanding of the effectiveness and reproducibility of this surgical technique.


2019 ◽  
Vol 11 (4) ◽  
pp. NP217-NP220
Author(s):  
Anuj Mehta ◽  
Vijayakumar Raju ◽  
Subramanian Muthukumaran ◽  
Soundaravalli Balakrishnan ◽  
Kalyanasundaram Muthuswamy

We report a rare case of combined supra- and infracardiac type of total anomalous pulmonary venous connection (mixed-type TAPVC) in a 26-day-old low birth weight (1.9 kg) infant who was admitted with respiratory distress. The child underwent successful surgical repair using a novel surgical technique and is doing well at one year follow-up.


2018 ◽  
Vol 6 (4_suppl2) ◽  
pp. 2325967118S0001
Author(s):  
Hagen Hommel

A bi-cruciate stabilized (BCS) guided-motion total knee arthroplasty (TKA) design was introduced to improve knee kinematics by more closely approximating those of a normal knee. Previous studies have shown a high incidence of complications with this implant type, which led to recent modifications of the design by the manufacturer. The current study was undertaken to assess whether the use of a guided-motion knee system with an extension-first surgical technique is associated with a similar rate of short-term adverse outcome as reported in literature. The secondary aim was to assess if there were any differences between the original and modified implant designs. This retrospective study enrolled 204 consecutive patients (204 knees) undergoing TKA for osteoarthritis of the knee, with the first 154 receiving cemented Journey BCS I implants and the remaining 51 receiving cemented Journey BCS II implants when these became available. At follow-up, patients were tested for the presence of iliotibial friction syndrome (ITB-F) and midflexion instability. Knee score and function score were taken preoperatively, at one year, and at final follow-up. Outcome data between the two implant types were compared using the Mann-Whitney test. No patients were lost to follow-up. Mean follow-up time for the cohort was 24.5 ± 7.8 months (range, 12 - 36 months). There were no cases of stiffness (flexion < 90°). Incidence of ITB-F syndrome was considered low: three (2.0%) knees in the BCS I group and two (3.9%) in the BCS II group (p = 0.367). Five (2.5%) knees presented with mild instability in midflexion, three (2.0%) in the BCS I group and two (3.9%) in the BCS II group (p = 0.367). One patient with a BCS I implant required reoperation for aseptic loosening 23 months postoperatively. At one-year follow-up, there were no significant differences in range of motion, knee score, or function score. When used in combination with an extension-first surgical technique, good early functional results with an acceptable rate of complications were obtained with both the original and the updated Journey BCS knee implant. Long-term follow-up studies are needed to confirm our findings.


2007 ◽  
Vol 177 (4S) ◽  
pp. 614-614
Author(s):  
Thorsten Bach ◽  
Thomas R.W. Herrmann ◽  
Roman Ganzer ◽  
Andreas J. Gross

2006 ◽  
Vol 175 (4S) ◽  
pp. 110-110 ◽  
Author(s):  
Robert D. Moore ◽  
John Miklos ◽  
L. Dean Knoll ◽  
Mary Dupont ◽  
Mickey Karram ◽  
...  

2006 ◽  
Vol 175 (4S) ◽  
pp. 332-333
Author(s):  
Jacques Hubert ◽  
Maṅo Chammas ◽  
Benoit Feillu ◽  
Eric Mourey ◽  
Usha Seshadri-Kreaden

Sign in / Sign up

Export Citation Format

Share Document