scholarly journals Micro-CT study of Middle Ordovician Spumellaria (radiolarians) from western Newfoundland, Canada

2020 ◽  
Vol 94 (3) ◽  
pp. 417-435 ◽  
Author(s):  
Sarah Kachovich ◽  
Jonathan C. Aitchison

AbstractA new, previously undescribed Middle Ordovician (middle Darriwilian: Dw2) radiolarian assemblage has been recovered from the Table Cove Formation at Piccadilly Quarry, western Newfoundland. Constituents of the fauna described herein are both distinctive and exceptionally well preserved. Three-dimensional X-ray micro-computed tomography (μ-CT) is used to make a detailed examination of four key spumellarian specimens. This technology enables visualization of hitherto ambiguous details of the internal morphologies of key lower Paleozoic taxonomic groups, among which a lack of knowledge has impeded resolution of higher taxonomic rankings.

2021 ◽  
pp. 1-31
Author(s):  
Sarah Kachovich ◽  
Jonathan C. Aitchison

Abstract New, distinctive, well-preserved and previously undescribed constituents of a Middle Ordovician (middle Darriwilian, Dw2) radiolarian assemblage from the Table Cove Formation in Newfoundland are described. Three-dimensional X-ray micro-computed tomography (μ-CT) facilitates detailed examination of key specimens revealing hitherto unknown details of the internal morphologies of key lower Paleozoic taxonomic groups, among which a lack of knowledge has previously impeded resolution of higher taxonomic rankings. Twenty-seven archaeospiculid and entactinarian taxa are described and illustrated including six new species: Westernbrookia polygonata n. sp., Neopalaeospiculum piccadilliensis n. sp., Ramuspiculum laxum n. sp. Spongentactinia nazarovi n. sp., Aspiculum irregulare n. sp., and Nyfrieslandia ramosissima n. sp. The investigation extends the known ranges of the species: Pararcheoentactinia reedae Won and Iams, 2002; Sphaeroentactinia robusta Won and Iams, 2015; Varispiculum ectospiculatum Won and Iams, 2015; and Svalbardospiculum multifurcatum (Won, Iams, and Reed, 2005), together with the genus Echidnina to the mid-Darriwilian. UUID: http://zoobank.org/74826b7b-bb86-45d5-ad23-e6e65e0706df.


2019 ◽  
Vol 34 (2) ◽  
pp. 97-102
Author(s):  
M. A. Rodriguez ◽  
T. T. Amon ◽  
J. J. M. Griego ◽  
H. Brown-Shaklee ◽  
N. Green

Advancements in computer technology have enabled three-dimensional (3D) reconstruction, data-stitching, and manipulation of 3D data obtained on X-ray imaging systems such as micro-computed tomography (μ-CT). Likewise, intuitive evaluation of these 3D datasets can be enhanced by recent advances in virtual reality (VR) hardware and software. Additionally, the generation, viewing, and manipulation of 3D X-ray diffraction datasets, such as pole figures employed for texture analysis, can also benefit from these advanced visualization techniques. We present newly-developed protocols for porting 3D data (as TIFF-stacks) into a Unity gaming software platform so that data may be toured, manipulated, and evaluated within a more-intuitive VR environment through the use of game-like controls and 3D headsets. We demonstrate this capability by rendering μ-CT data of a polymer dogbone test bar at various stages of in situ mechanical strain. An additional experiment is presented showing 3D XRD data collected on an aluminum test block with vias. These 3D XRD data for texture analysis (χ, ϕ, 2θ dimensions) enables the viewer to visually inspect 3D pole figures and detect the presence or absence of in-plane residual macrostrain. These two examples serve to illustrate the benefits of this new methodology for multidimensional analysis.


2019 ◽  
Vol 809 ◽  
pp. 587-593
Author(s):  
Simon Zabler ◽  
Katja Schladitz ◽  
Kilian Dremel ◽  
Jonas Graetz ◽  
Dascha Dobrovolskij

To detect and characterize materials defects in fiber composites as well as for evaluatingthe three-dimensional local fiber orientation in the latter, X-ray micro-CT is the preferred methodof choice. When micro computed tomography is applied to inspect large components, the method isreferred to as region-of-interest computed tomography. Parts can be as large as 10 cm wide and 1 mlong, while the measurement volume of micro computed tomography is a cylinder of only 4 − 5 mmdiameter (typical wall thickness of fiber composite parts). In this report, the potentials and limits ofregion-of-interest computed tomography are discussed with regard to spatial resolution and precisionwhen evaluating defects and local fiber orientation in squeeze cast components. The micro computedtomography scanner metRIC at Fraunhofer‘s Development Center X-ray Technology EZRT deliversregion-of-interest computed tomography up to a spatial resolution of 2 μm/voxel, which is sufficientfor determining the orientation of natural or synthetic fibers, wood, carbon and glass. The mean localfiber orientation is estimated on an isotropic structuring element of approximately 0.1 mm length bymeans of volume image analysis (MAVI software package by Fraunhofer ITWM). Knowing the exactlocal fiber orientation is critical for estimating anisotropic thermal conductivity and materials strength.


2020 ◽  
Author(s):  
Carlo Porfido ◽  
Roberto Rizzo ◽  
David Healy ◽  
Matteo Spagnuolo ◽  
Roberto Terzano ◽  
...  

<div><div><div><p>This work presents a study on the fracturing behaviour of a quartz tempered clay-based ceramic subjected to damage in freeze-thaw cycles. X-ray micro-computed tomography (micro-CT) provided high-resolution imaging of the ceramic before and during the freeze-thaw treatment, allowing to analyse a fully water-saturated sample using a special thermal stage designed to keep the sample frozen during analyses. Micro-CT 3D renderings showed the internal features of the specimen (i.e., quartz grain distribution), the increment of fracture count and size, and the detachment of ceramic and/or temper fragments from the edges of the sample over the cycles. Selected 2D micrographs, before and after freeze-thawing treatment, were analysed using the MATLAB toolbox FracPaQ. This software provided detailed data on fracture length, intensity, density, orientation and connectivity, and enabled to interpret the process of fracture initiation and propagation inside the material. These results showed that the temper plays a crucial role in ceramic fracturing behaviour under freeze- thawing conditions, as damage propagation is influenced by quartz grain distribution and orientation within the material. The study described in this work, not only offers new insights into the fracture dynamics of freeze-thawed clay-based ceramics, but also presents a new methodological approach to quantitatively measure fracture damage in porous materials.</p></div></div></div>


Author(s):  
Daniel H. Morse ◽  
Arlyn J. Antolak ◽  
Bernice E. Mills

X-ray radiography has long been recognized as a valuable tool for detecting internal features and flaws. Recent developments in microfabrication and composite materials have extended inspection requirements to the resolution limits of conventional radiography. Our work has been directed toward pushing both detection and measurement capabilities to a smaller scale. Until recently, we have used conventional contact radiography, optimized to resolve small features. With the recent purchase of a nano-focus (sub-micron) x-ray source, we are now investigating projection radiography, phase contrast imaging and micro-computed tomography (μ-CT). Projection radiography produces a magnified image that is limited in spatial resolution mainly by the source size, not by film grain size or detector pixel size. Under certain conditions phase contrast can increase the ability to resolve small features such as cracks, especially in materials with low absorption contrast. Micro-computed tomography can provide three-dimensional measurements on a micron scale and has been shown to provide better sensitivity than simple radiographs. We have included applications of these techniques to small-scale measurements not easily made by mechanical or optical means. Examples include void detection in meso-scale nickel MEMS parts, measurement of edge profiles in thick gold lithography masks, and characterization of the distribution of phases in composite materials. Our work, so far, has been limited to film.


Materials ◽  
2020 ◽  
Vol 13 (16) ◽  
pp. 3606
Author(s):  
Armin Rashidi ◽  
Tina Olfatbakhsh ◽  
Bryn Crawford ◽  
Abbas S. Milani

X-ray computed tomography provides qualitative and quantitative structural and compositional information for a broad range of materials. Yet, its contribution to the field of advanced composites such as carbon fiber reinforced polymers is still limited by factors such as low imaging contrast, due to scarce X-ray attenuation features. This article, through a review of the state of the art, followed by an example case study on Micro-computed tomography (CT) analysis of low X-ray absorptive dry and prepreg carbon woven fabric composites, aims to highlight and address some challenges as well as best practices on performing scans that can capture key features of the material. In the case study, utilizing an Xradia Micro-CT-400, important aspects such as obtaining sufficient contrast, an examination of thin samples, sample size/resolution issues, and image-based modeling are discussed. The outcome of an optimized workflow in Micro-CT of composite fabrics can assist in further research efforts such as the generation of surface or volume meshes for the numerical modeling of underlying deformation mechanisms during their manufacturing processes.


Sign in / Sign up

Export Citation Format

Share Document