scholarly journals A Southern-Hemisphere all-sky radio transient monitor for SKA-Low prototype stations

Author(s):  
M. Sokolowski ◽  
R. B. Wayth ◽  
N. D. R. Bhat ◽  
D. Price ◽  
J. W. Broderick ◽  
...  

Abstract We present the first Southern-Hemisphere all-sky imager and radio-transient monitoring system implemented on two prototype stations of the low-frequency component of the Square Kilometre Array (SKA-Low). Since its deployment, the system has been used for real-time monitoring of the recorded commissioning data. Additionally, a transient searching algorithm has been executed on the resulting all-sky images. It uses a difference imaging technique to enable identification of a wide variety of transient classes, ranging from human-made radio-frequency interference to genuine astrophysical events. Observations at the frequency 159.375 MHz and higher in a single coarse channel ( $\approx$ 0.926 MHz) were made with 2 s time resolution, and multiple nights were analysed generating thousands of images. Despite having modest sensitivity ( $\sim$ few Jy beam–1), using a single coarse channel and 2-s imaging, the system was able to detect multiple bright transients from PSR B0950+08, proving that it can be used to detect bright transients of an astrophysical origin. The unusual, extreme activity of the pulsar PSR B0950+08 (maximum flux density $\sim$ 155 Jy beam–1) was initially detected in a ‘blind’ search in the 2020 April 10/11 data and later assigned to this specific pulsar. The limitations of our data, however, prevent us from making firm conclusions of the effect being due to a combination of refractive and diffractive scintillation or intrinsic emission mechanisms. The system can routinely collect data over many days without interruptions; the large amount of recorded data at 159.375 and 229.6875 MHz allowed us to determine a preliminary transient surface density upper limit of $1.32 \times 10^{-9} \text{deg}^{-2}$ for a timescale and limiting flux density of 2 s and 42 Jy, respectively. In the future, we plan to extend the observing bandwidth to tens of MHz and improve time resolution to tens of milliseconds in order to increase the sensitivity and enable detections of fast radio bursts below 300 MHz.

2005 ◽  
Vol 23 (8) ◽  
pp. 2803-2811 ◽  
Author(s):  
J. B. Cao ◽  
Z. X. Liu ◽  
J. Y. Yang ◽  
C. X. Yian ◽  
Z. G. Wang ◽  
...  

Abstract. LFEW is a low frequency electromagnetic wave detector mounted on TC-2, which can measure the magnetic fluctuation of low frequency electromagnetic waves. The frequency range is 8 Hz to 10 kHz. LFEW comprises a boom-mounted, three-axis search coil magnetometer, a preamplifier and an electronics box that houses a Digital Spectrum Analyzer. LFEW was calibrated at Chambon-la-Forêt in France. The ground calibration results show that the performance of LFEW is similar to that of STAFF on TC-1. The first results of LFEW show that it works normally on board, and that the AC magnetic interference of the satellite platform is very small. In the plasmasphere, LFEW observed the ion cyclotron waves. During the geomagnetic storm on 8 November 2004, LFEW observed a wave burst associated with the oxygen ion cyclotron waves. This observation shows that during geomagnetic storms, the oxygen ions are very active in the inner magnetosphere. Outside the plasmasphere, LFEW observed the chorus on 3 November 2004. LFEW also observed the plasmaspheric hiss and mid-latitude hiss both in the Southern Hemisphere and Northern Hemisphere on 8 November 2004. The hiss in the Southern Hemisphere may be the reflected waves of the hiss in the Northern Hemisphere.


1987 ◽  
Vol 81 (S1) ◽  
pp. S11-S11
Author(s):  
R. N. Denham ◽  
R. W. Bannister ◽  
K. M. Guthrie ◽  
R. H. Mellen ◽  
D. G. Browning

Frequenz ◽  
2017 ◽  
Vol 71 (11-12) ◽  
Author(s):  
Xue Jiao ◽  
Bo Yang

AbstractTo study the lightning electromagnetic pulse (LEMP) coupling and protection problems of shielding enclosure with penetrating wire, we adopt the model with proper size which is close to the practical engineering and the two-step finite-difference time-domain (FDTD) method is used for calculation in this paper. It is shown that the coupling voltage on the circuit lead inside the enclosure increases about 34 dB, when add 1.0 m long penetrating wire at the aperture, comparing with the case without penetrating wire. Meanwhile, the waveform, has the same wave outline as the lightning current source, shows that the penetrating wire brings a large number of low frequency component into the enclosure. The coupling effect in the enclosure will reduce greatly when penetrating wire has electrical connection with the enclosure at the aperture and the coupling voltage increase only about 12 dB than the case without penetrating wire. Moreover, the results show that though the waveguide pipe can reduce the coupling effect brought by the penetrating wire, the exposing part of penetrating wire can increase the coupling when the penetrating wire outside the enclosure is longer than the waveguide pipe and the longer the exposing part is, the stronger the coupling is.


Author(s):  
Sara Kobbi ◽  
Salima Guerricha ◽  
Smaïl Chihi ◽  
Abdallah Bekkouche ◽  
Mohammed Tayeb Meftah

2004 ◽  
Vol 11 (2) ◽  
pp. 215-218 ◽  
Author(s):  
S. G. Tagare ◽  
S. V. Singh ◽  
R. V. Reddy ◽  
G. S. Lakhina

Abstract. Small amplitude electron - acoustic solitons are studied in a magnetized plasma consisting of two types of electrons, namely cold electron beam and background plasma electrons and two temperature ion plasma. The analysis predicts rarefactive solitons. The model may provide a possible explanation for the perpendicular polarization of the low-frequency component of the broadband electrostatic noise observed in the Earth's magnetotail.


10.14311/450 ◽  
2003 ◽  
Vol 43 (4) ◽  
Author(s):  
P. Hasal ◽  
I. Fořt ◽  
J. Kratěna

Experimental data obtained by measuring the tangential component of the force affecting radial baffles in a flat-bottomed cylindrical mixing vessel stirred with a Rushton turbine impeller is analysed. Spectral analysis of the experimental data demonstrated the presence of its macro-instability (MI) related low-frequency component embedded in the total force. Two distinct dimensionless frequencies (both directly proportional to the impeller speed of rotation N) of the occurence of the MI component were detected: a lower frequency of approximately 0.025N and a higher frequency of about 0.085N. The relative magnitude QMI of the MI-related component of the total tangential force was evaluated by a combination of proper orthogonal decomposition (POD) and spectral analysis. The values of magnitude QMI varied in the interval [rom approximately 0.05 to 0.30. The magnitude QMI takes maximum values at low Reynolds number values (in laminar and transitional regions). In the turbulent region (ReM >20000) the QMI value is low and practically constant. The dependence oj the QMI values on vertical position in the vessel is only marginal. The results suggest that the magnitude of the MI component of the force is significantly influenced by the liquid viscosity and density.


2017 ◽  
Vol 46 (2) ◽  
pp. 792-801 ◽  
Author(s):  
W-J Guo ◽  
S-K Yao ◽  
Y-L Zhang ◽  
S-Y Du ◽  
H-F Wang ◽  
...  

Objective This study was performed to investigate impaired vagal activity to meal in patients with functional dyspepsia (FD) with delayed gastric emptying (GE). Methods Eighty-five patients were studied. GE parameters, including those in the overall and proximal stomach, were measured by GE functional tests at the Department of Nuclear Medicine. Autonomic nervous function was tested by spectral analysis of heart rate variability (HRV). The vagal activity and sympathetic activity were analyzed by recording the power in the high-frequency component (HF), low-frequency component (LF), and LF/HF ratio. Results Overall and proximal GE were delayed in 47.2% and 50.9% of the patients, respectively. Spectral analysis of HRV showed that the HF in patients with delayed proximal GE was significantly lower and that the LF/HF ratio was significantly higher than those in patients with normal proximal GE after a meal. Conclusion Delayed proximal GE might be caused by disrupted sympathovagal balance as a result of decreased vagal activity after a meal. Improvement in vagal activity may constitute an effective treatment method for patients with FD.


1992 ◽  
Vol 114 (1) ◽  
pp. 26-31 ◽  
Author(s):  
M. Suk ◽  
T. Ishii ◽  
D. Bogy

We investigate the influence of crown on slider dynamics during the takeoff stages of disk drives using the multi-channel laser interferometer. We show that a two-dimensional analysis of slider dynamics during takeoff/landing cannot explain all the observed phenomena. We also examine the crown effect on slider motion while it is flying on a thin film disk with a crater-like surface defect. Finally, we measure the spacing variation of the slider as a function of disk speed. It is observed that the initial motion of negative crown sliders during takeoff can be quite similar to positive crown sliders, although the process is quite different. Furthermore, the results suggest that the negative crown sliders may lead to more disk wear due to longer sliding distances. We observed that during steady flying conditions the craterlike surface defect on the disk produced significantly larger motions for negative crown sliders than positive crown sliders. Lastly, we found that both the waveform and magnitude of the low frequency component of the spacing fluctuation is independent of the slider flying height.


2014 ◽  
Vol 610 ◽  
pp. 789-796
Author(s):  
Jiang Bao Li ◽  
Zhen Hong Jia ◽  
Xi Zhong Qin ◽  
Lei Sheng ◽  
Li Chen

In order to improve the prediction accuracy of busy telephone traffic, this study proposes a busy telephone traffic prediction method that combines wavelet transformation and least square support vector machine (lssvm) model which is optimized by particle swarm optimization (pso) algorithm. Firstly, decompose the pretreatment of busy telephone traffic data with mallat algorithm and get low frequency component and high frequency component. Secondly, reconfigure each component and use pso_lssvm model predict each reconfigured one. Then the busy telephone traffic can be achieved. The experimental results show that the prediction model has higher prediction accuracy and stability.


Sign in / Sign up

Export Citation Format

Share Document