scholarly journals Addendum

1987 ◽  
Vol 29 (2) ◽  
pp. 275-275

A Diophantine Equationby J. W. S. CasselsDr A. Mąkowski of the University of Warsaw has informed me that the result of my paper published in the Glasgow Mathematical Journal 27 (1985), 11–18 was anticipated by S. Uchiyama in his paper “On a diophantine equation”, Proc. Japan Acad. Ser. A, 55 (1979), 367–369.

PMLA ◽  
1935 ◽  
Vol 50 (4) ◽  
pp. 1343-1343

The fifty-second meeting of the Modern Language Associationof America was held, on the invitation of the University of Cincinnati, at Cincinnati, Ohio, Monday, Tuesday, and Wednesday, December 30 and 31, 1935, and January 1, 1936. The Association headquarters were in the Netherland Plaza Hotel, where all meetings were held except those of Tuesday morning and afternoon. These took place at the University of Cincinnati. Registration cards at headquarters were signed by about 900, though a considerably larger number of members were in attendance. The Local Committee estimated the attendance at not less than 1400. This Committee consisted of Professor Frank W. Chandler, Chairman; Professor Edwin H. Zeydel; Professor Phillip Ogden; Mr. John J. Rowe (for the Directors); and Mr. Joseph S. Graydon (for the Alumni).


1966 ◽  
Vol 24 ◽  
pp. 116-117
Author(s):  
P.-I. Eriksson

Nowadays more and more of the reductions of astronomical data are made with electronic computers. As we in Uppsala have an IBM 1620 at the University, we have taken it to our help with reductions of spectrophotometric data. Here I will briefly explain how we use it now and how we want to use it in the near future.


1979 ◽  
Vol 46 ◽  
pp. 96-101
Author(s):  
J.A. Graham

During the past several years, a systematic search for novae in the Magellanic Clouds has been carried out at Cerro Tololo Inter-American Observatory. The Curtis Schmidt telescope, on loan to CTIO from the University of Michigan is used to obtain plates every two weeks during the observing season. An objective prism is used on the telescope. This provides additional low-dispersion spectroscopic information when a nova is discovered. The plates cover an area of 5°x5°. One plate is sufficient to cover the Small Magellanic Cloud and four are taken of the Large Magellanic Cloud with an overlap so that the central bar is included on each plate. The methods used in the search have been described by Graham and Araya (1971). In the CTIO survey, 8 novae have been discovered in the Large Cloud but none in the Small Cloud. The survey was not carried out in 1974 or 1976. During 1974, one nova was discovered in the Small Cloud by MacConnell and Sanduleak (1974).


1979 ◽  
Vol 46 ◽  
pp. 368
Author(s):  
Clinton B. Ford

A “new charts program” for the Americal Association of Variable Star Observers was instigated in 1966 via the gift to the Association of the complete variable star observing records, charts, photographs, etc. of the late Prof. Charles P. Olivier of the University of Pennsylvania (USA). Adequate material covering about 60 variables, not previously charted by the AAVSO, was included in this original data, and was suitably charted in reproducible standard format.Since 1966, much additional information has been assembled from other sources, three Catalogs have been issued which list the new or revised charts produced, and which specify how copies of same may be obtained. The latest such Catalog is dated June 1978, and lists 670 different charts covering a total of 611 variables none of which was charted in reproducible standard form previous to 1966.


Author(s):  
Ronald S. Weinstein ◽  
N. Scott McNutt

The Type I simple cold block device was described by Bullivant and Ames in 1966 and represented the product of the first successful effort to simplify the equipment required to do sophisticated freeze-cleave techniques. Bullivant, Weinstein and Someda described the Type II device which is a modification of the Type I device and was developed as a collaborative effort at the Massachusetts General Hospital and the University of Auckland, New Zealand. The modifications reduced specimen contamination and provided controlled specimen warming for heat-etching of fracture faces. We have now tested the Mass. General Hospital version of the Type II device (called the “Type II-MGH device”) on a wide variety of biological specimens and have established temperature and pressure curves for routine heat-etching with the device.


Author(s):  
Hans Ris

The High Voltage Electron Microscope Laboratory at the University of Wisconsin has been in operation a little over one year. I would like to give a progress report about our experience with this new technique. The achievement of good resolution with thick specimens has been mainly exploited so far. A cold stage which will allow us to look at frozen specimens and a hydration stage are now being installed in our microscope. This will soon make it possible to study undehydrated specimens, a particularly exciting application of the high voltage microscope.Some of the problems studied at the Madison facility are: Structure of kinetoplast and flagella in trypanosomes (J. Paulin, U. of Georgia); growth cones of nerve fibers (R. Hannah, U. of Georgia Medical School); spiny dendrites in cerebellum of mouse (Scott and Guillery, Anatomy, U. of Wis.); spindle of baker's yeast (Joan Peterson, Madison) spindle of Haemanthus (A. Bajer, U. of Oregon, Eugene) chromosome structure (Hans Ris, U. of Wisconsin, Madison). Dr. Paulin and Dr. Hanna are reporting their work separately at this meeting and I shall therefore not discuss it here.


Author(s):  
Mircea Fotino

A new 1-MeV transmission electron microscope (Model JEM-1000) was installed at the Department of Molecular, Cellular and Developmental Biology of the University of Colorado in Boulder during the summer and fall of 1972 under the sponsorship of the Division of Research Resources of the National Institutes of Health. The installation was completed in October, 1972. It is installed primarily for the study of biological materials without many of the limitations hitherto unavoidable in standard transmission electron microscopy. Only the technical characteristics of the installation are briefly reviewed here. A more detailed discussion of the experimental program under way is being published elsewhere.


Author(s):  
John W. Coleman

The injector to be described is a component in the Electron Injector-Linear Accelerator—Condenser Module for illumination used on the variable 100-500kV electron microscope being built at the Radio Corporation of America for the University of Virginia.The injector is an independently powered, autonomous unit, operating at a constant 6kV positive with respect to accelerator potential, thereby making beam current independent of accelerator potential. The injector provides for on-axis ion trapping to prolong filament lifetime, and incorporates a derived Einzel lens for optical integration into the overall illumination system for microscopy. Electrostatic beam deflectors for alignment are an integral part of the apparatus. The entire injector unit is cantilevered off a door for side loading, and is topped with a 4-filament turret released electrically but driven by a self-contained Negator spring motor.


Author(s):  
S. Edith Taylor ◽  
Patrick Echlin ◽  
May McKoon ◽  
Thomas L. Hayes

Low temperature x-ray microanalysis (LTXM) of solid biological materials has been documented for Lemna minor L. root tips. This discussion will be limited to a demonstration of LTXM for measuring relative elemental distributions of P,S,Cl and K species within whole cells of tobacco leaves.Mature Wisconsin-38 tobacco was grown in the greenhouse at the University of California, Berkeley and picked daily from the mid-stalk position (leaf #9). The tissue was excised from the right of the mid rib and rapidly frozen in liquid nitrogen slush. It was then placed into an Amray biochamber and maintained at 103K. Fracture faces of the tissue were prepared and carbon-coated in the biochamber. The prepared sample was transferred from the biochamber to the Amray 1000A SEM equipped with a cold stage to maintain low temperatures at 103K. Analyses were performed using a tungsten source with accelerating voltages of 17.5 to 20 KV and beam currents from 1-2nA.


Sign in / Sign up

Export Citation Format

Share Document