International recognition of the Chronic Otitis Media Questionnaire 12

2017 ◽  
Vol 131 (6) ◽  
pp. 514-517 ◽  
Author(s):  
S I Kosyakov ◽  
J V Minavnina ◽  
J S Phillips ◽  
M W Yung

AbstractObjective:The Chronic Otitis Media Questionnaire 12 was developed initially in the UK to assess patient-reported health-related quality of life associated with chronic otitis media. This study aimed to determine whether this tool is applicable to the Russian population, which has a materially different healthcare system.Method:A total of 108 patients with different forms of chronic otitis media completed the Russian Chronic Otitis Media Questionnaire 12.Results:The average Russian Chronic Otitis Media Questionnaire 12 score was 19.4 (standard deviation = 8.3). The internal consistency of the Russian Chronic Otitis Media Questionnaire 12 was high, with a Cronbach's alpha value of 0.860.Conclusion:The Russian version of the Chronic Otitis Media Questionnaire 12 was found to be a reliable tool for the assessment of health-related quality of life in patients with chronic otitis media. This sets the scene for international collaboration, using this tool to assess the effectiveness of surgical treatments even amongst countries with different healthcare systems.

2017 ◽  
Vol 22 (02) ◽  
pp. 108-112 ◽  
Author(s):  
Prashanth Prabhu ◽  
Anusha Chandrashekar ◽  
Anita Jose ◽  
Aishwarya Ganeshan ◽  
Lavanya Kiruthika

Introduction It is essential to determine the quality of life among individuals with chronic suppurative otitis media (CSOM). However, there is limited literature on health-related quality of life measurements in Kannada-speaking individuals with CSOM. Objectives The present study attempted to translate and validate Chronic Suppurative Otitis Media Questionnaire-12 (COMQ-12) and Chronic Otitis Media Outcome Test-15 (COMOT-15) in Kannada. Method The English questionnaires were translated and back-translated, and they were later verified for content validity. The developed questionnaires were then administered to 100 individuals with CSOM for further validation. Results The results of the study showed that the translated questionnaires have good internal consistency for measuring quality of life among individuals with CSOM. The study also showed that Kannada-speaking individuals with CSOM show significant impairment in their health-related quality of life measures. Conclusions The impairments were more related to ear symptoms and psychological issues. However, test-retest reliability of the developed questionnaire and its further validation are essential. Thus, these questionnaires attempt to understand the problems of the individuals with CSOM from the patients' perspective and help clinicians provide the appropriate management.


2020 ◽  
Author(s):  
Ana M. Otoya Tono ◽  
Lucía C. Pérez Herrera ◽  
Daniel Peñaranda García ◽  
Sergio Moreno López ◽  
Ricardo Sánchez Pedraza ◽  
...  

Abstract Background Evaluation of health-related quality of life (HRQoL) is considered an important aspect of clinical assessment and health research. Chronic Otitis Media (COM) is related to the quality of life deterioration subsequent to COM symptoms, social communication impairments and lower work performance. However, there is no reliable information regarding the impact of this disease on health and quality of life in many resource-poor countries. Therefore, we translated into Spanish and culturally adapted the Chronic Otitis Media Questionnaire-12 (COMQ-12) for the evaluation of Health-Related Quality of Life (HRQoL) of Chronic Otitis Media (COM) in adult patients. Also, we assessed the psychometric properties of our version of the questionnaire.Methods Two otology referral centers in Bogotá, Colombia were included. The Spanish version of COMQ-12 was applied twice to 200 adult patients with confirmed COM diagnosis and to 31 healthy controls in order to perform the validation process and assess the internal consistency of this questionnaire. Psychometric characteristics (replicability, reliability, and validity) of the COMQ-12 were assessed. Exploratory Factor Analysis (EFA) and Confirmatory Factor Analysis (CFA) were conducted via structural equation modeling (SEM) in order to test the questionnaire’s structure.Results The Spanish version of the COMQ-12 showed good internal consistency (Cronbach’s Alpha=0.8526, McDonald’s Omega = 0.8901). Coefficients corresponding to Lin’s Concordance test and test-retest reliability were 0.945 and 0.82 respectively. Correlation between the Visual Analogue Scale (VAS) and the COMQ-12 was = 0.676 (IC 95% = 0.593; 0.745). Factor analysis of the Spanish version of the COMQ-12 indicated a questionnaire structure with three domains: smelly discharge related symptoms; hearing loss related symptoms; and impact on work, lifestyle and health services.Conclusion This Spanish version of the COMQ-12 showed high reliability and high internal consistency. This questionnaire can be used as an objective clinical tool to assess the HRQoL of patients who have a COM diagnosis.


2020 ◽  
Author(s):  
Ana M. Otoya-Tono ◽  
Lucía C. Pérez-Herrera ◽  
Daniel Peñaranda ◽  
Sergio Moreno-López ◽  
Ricardo Sánchez-Pedraza ◽  
...  

Abstract Background: Evaluation of health-related quality of life (HRQoL) is considered an important aspect of clinical assessment and health research. Chronic Otitis Media (COM) is related to the quality of life deterioration subsequent to COM symptoms, social communication impairments, and lower work performance. However, there is no reliable information regarding the impact of this disease on health and quality of life in many resource-poor countries. Therefore, we translated into Spanish and culturally adapted the Chronic Otitis Media Questionnaire-12 (COMQ-12) for the evaluation of HRQoL of Chronic Otitis Media (COM) in adult patients. Also, we assessed the psychometric properties of the Spanish version of the questionnaire. Methods: Two otology referral centers in Bogotá, Colombia were included. The Spanish version of COMQ-12 was applied twice to 200 adult patients with confirmed COM diagnosis and 31 healthy controls to perform the validation process and assess the internal consistency of this questionnaire. Psychometric characteristics (internal consistency, test-retest reliability, and construct validity) of the COMQ-12 were assessed. Exploratory Factor Analysis (EFA) and Confirmatory Factor Analysis (CFA) were conducted via structural equation modeling (SEM) to test the questionnaire’s structure. Results: The Spanish version of the COMQ-12 showed good internal consistency (Cronbach’s Alpha: 0.852, McDonald’s Omega: 0.890). Coefficients corresponding to Lin’s Concordance test and test-retest reliability were 0.945 and 0.825 respectively. Correlation between the Visual Analogue Scale (VAS) and the COMQ-12 was 0.676 (95% CI: 0.593; 0.745) . Factor analysis of the Spanish version of the COMQ-12 indicated a questionnaire structure with three domains: smelly discharge related symptoms; hearing loss related symptoms; and impact on work, lifestyle, and health services . Conclusion: This Spanish version of the COMQ-12 showed high reliability and high internal consistency. This questionnaire can be used as an objective clinical tool to assess the HRQoL of patients who have a COM diagnosis. Trial registration Not applicable. Key Words: Chronic Suppurative Otitis Media, Health-Related Quality of Life, COMQ-12, validity.


2020 ◽  
Vol 59 (3) ◽  
pp. 120-127
Author(s):  
Domen Vozel ◽  
Nejc Steiner ◽  
Nina Božanić Urbančič ◽  
Dejan Mladenov ◽  
Saba Battelino

AbstractPurposeTo provide physicians and patients with the tools needed to evaluate patients’ problems and health-related quality of life by cross-culturally adapting and validating the Chronic Otitis Media Questionnaire 12 (COMQ-12), the Dizziness Handicap Inventory (DHI), the Neuropsychological Vertigo Inventory (NVI) and the Tinnitus Handicap Inventory (THI).Materials and methodsCOMQ-12, DHI, NVI and THI were translated into the Slovenian language and completed by patients treated at our department for chronic otitis media, vertigo or tinnitus. The control group for each questionnaire consisted of healthy volunteers. Internal consistency, test-retest reliability, discriminant validity, diagnostic accuracy and cut-off value were determined for each questionnaire.ResultsTest-retest reliability was excellent for DHI (ICC A=0.946) and NVI (p=0.315, ICC A=0.975), good to excellent for COMQ-12 (p=0.680, ICC A=0.858) and satisfactory for THI (p=0.120). Discriminant validity was confirmed for each questionnaire (p>0.05) using the Mann-Whitney U test (COMQ-12, DHI, THI) or the Welch t-test (NVI). COMQ-12 had acceptable (α=0.796) and DHI (α=0.910), NVI (α=0.950) and THI (α=0.924) perfect internal consistency. COMQ-12 and DHI had excellent, NVI acceptable and THI perfect diagnostic accuracy (AUC=0.987, AUC=0.999, AUC=0.781 and AUC=1.000 respectively). Cut-off values determined by Youden’s index were 7, 7, 9 and 56 for COMQ-12, THI, DHI and NVI, respectively.ConclusionSlovenian COMQ-12, DHI, NVI and THI are a valid and accurate tool for the diagnosis and measurement of health-related quality of life in patients with chronic otitis media, vertigo and tinnitus. They could aid general practitioners, occupational health specialists, neurologists and otorhinolaryngologists.


PLoS ONE ◽  
2020 ◽  
Vol 15 (12) ◽  
pp. e0244797
Author(s):  
Lucia C. Pérez-Herrera ◽  
Daniel Peñaranda ◽  
Sergio Moreno-López ◽  
Ana M. Otoya-Tono ◽  
Lorena Gutiérrez- Velasco ◽  
...  

Background Despite the high prevalence of chronic otitis media (COM) in low to middle-income countries, there are few studies regarding its associated factors, health-related quality of life, and treatment costs. This study aimed to identify associated factors of COM, assess its impact on the quality of life as well as estimate the patients’ reported costs of COM treatment in Colombia. Methods Cross-sectional study. Two otology-referral centers in Bogotá (Colombia) were included. Questionnaires focusing on sociodemographic and clinical associated factors, quality of life, and patients’ reported costs were administered to 200 adults with COM diagnosis and 144 control adults. Otoscopic evaluation and audiometric data were collected. Results The mean age was 42.2 years (SD: 14.44). The median length of COM was 26.13 years (SD: 17.06), and 79.5% of the COM patients reported otorrhea during childhood (P-value: 0.01). The most frequently reported allergic disease among our study population was allergic rhinitis (26.5%). COM was less frequent in patients with a medium-high socioeconomic status (PR: 0.54; 95% CI: 0.39–0.72), and more frequent in patients who reported increased ear discharge due to upper respiratory tract infections (PR: 1.69; 95% CI: 1.68–1.70). The global score of the “Chronic Suppurative Otitis Media Questionnaire-12” showed a difference of 9 points between patients with active and inactive COM (P < 0.001). Patients spent between 12.07% to 60.37% of their household income on expenses related to COM. Conclusions Associated factors found in this study are consistent with previous reports. COM has a significant financial impact and affects patients’ quality of life. Worldwide research addressing these issues in poor-resource countries is scarce, further studies are needed.


2018 ◽  
Vol 84 (6) ◽  
pp. 708-712 ◽  
Author(s):  
Anna Carolina Oliveira Fonseca ◽  
Pedro Ramos ◽  
Fernando A. Balsalobre ◽  
Edson L. Freitas ◽  
John S. Phillips ◽  
...  

Author(s):  
Robert Mlynski ◽  
David Bächinger ◽  
Theresa Langanke ◽  
Susen Lailach ◽  
Marcus Neudert ◽  
...  

Abstract Purpose Evaluating the current health state in chronic otitis media (COM), audiologic results are complemented by subjective outcomes, such as health-related quality of life (HRQoL). Two disease-specific instruments assessing HRQoL in COM in German-speaking patients exist, i.e., the chronic otitis media outcome test (COMOT-15) and the Zurich chronic middle ear inventory (ZCMEI-21). Since the psychometric properties of these questionnaires in a concurrent application are unknown, the aim of this study was to compare the COMOT-15 and the ZCMEI-21. Methods HRQoL was assessed in adult COM patients using the COMOT-15 and the ZCMEI-21. Psychometric properties were determined, including response distribution, concurrent validity, internal consistency, correlation to hearing and gender differences. Results In 173 patients (mean age 51.5 years), both questionnaires showed normally distributed scores without strong floor and ceiling effects. The total scores and subscores of both questionnaires exhibited satisfactory internal consistency (Cronbach’s α 0.7–0.9) with the exception of the COMOT-15 hearing subscore (α = 0.94) and the ZCMEI-21 medical resource subscore (α = 0.66). Fair correlations between the air conduction pure-tone average and the total scores were found (COMOT-15: r = 0.36, p < 0.0001; ZCMEI-21: r = 0.34, p < 0.0001). Conclusion In the first study comparing the COMOT-15 and the ZCMEI-21, both questionnaires exhibited satisfactory psychometric properties with several subtle differences. The COMOT-15 has a strong focus on hearing with a probably redundant content of the hearing subscore and may be suited for hearing-focused research questions. The ZCMEI-21 provides a comprehensive assessment of the COM symptom complex and may therefore also be used in research settings, where ear discharge, vertigo or pain should be covered.


Sign in / Sign up

Export Citation Format

Share Document