Impact of atrial septal defect device size on biventricular global and regional function: a two-dimensional strain echocardiographic study

2021 ◽  
pp. 1-9
Author(s):  
Areej Alkhateeb ◽  
Alaa Roushdy ◽  
Hosam Hasan-Ali ◽  
Yehia T. Kishk ◽  
Aya El Sayegh ◽  
...  

ABSTRACT Objective: In this study, we assessed the acute changes in biventricular longitudinal strain after atrial septal defect transcatheter closure and its relation to the device size. Methods: Hundred atrial septal defect patients and 40 age-matched controls were included. Echocardiography and strain study were performed at baseline and 24 hours and 1 month after the intervention. The study group was divided into two subgroups; group 1: smaller devices were used (mean device size = 1.61 ± 0.05 cm, n = 74) and group 2: larger devices were used (mean device size = 2.95 ± 0.07 cm, n = 26). Results: At baseline, there was a significant difference between the study group and controls as regards right ventricular global longitudinal strain with significant hyperkinetic apex (p = 0.033, p = 0.020, respectively). There was a significant immediate reduction in right ventricular global longitudinal strain (from −24.43 ± 0.49% to −21.62 ± 0.47%, p < 0.001), which showed insignificant improvement after 1-month follow-up. While only left ventricular global longitudinal strain increased after 1 month. Within 24 hours of device closure, all the basal- and mid-lateral segments strains and apical right ventricular strains showed a significant reduction. There was a significant negative correlation between the indexed large device size and an immediate change in the right ventricular global longitudinal strain (r = −0.425, p = 0.034). Conclusion: Significant right ventricular global longitudinal strain reduction starts as early as 24 hours after transcatheter closure, irrespective of the device size used. The rapid impact of closure was mainly on the biventricular basal and lateral segments and right ventricular apical ones, especially with the large sized atrial septal defect.

2020 ◽  
Vol 21 (Supplement_1) ◽  
Author(s):  
O Seckin ◽  
S Unlu ◽  
G Tacoy

Abstract Background The function of both ventricles have been suggested to be affected in patients with mitral stenosis. In this study, it was aimed to investigate deformation properties of right (RV) and left ventricles (LV) in mild and moderate rheumatic mitral stenosis (MS) patients with three-dimensional speckle tracking echocardiography (3D-STE). Methods A total of 60 patients were included in the study (20 patients with mild MS diagnosis, 20 patients with moderate MS diagnosis and 20 healthy volunteers). Three-dimensional echocardiography datasets were obtained for both ventricles in all patients. An example for RV assessment is shown in Figure 1. LV global longitudinal strain (GLS), LV torsion, RV free wall (FW) LS and interventricular septal (IVS) LS measurements were analyzed. Results The LV ejection fraction (EF), RV fractional area change and tricuspid annular plane systolic excursion values were statistically similar and in the normal range. The LV GLS measurements were significantly different among the groups by being highest in the control group and least in the moderate stenosis group (ANOVA,p &lt; 0.001) (Table 1). Patients with MS showed higher torsional values, correlated with MS severity (ANOVA,p &lt; 0.001) (Table 1). IVS LS, RVFW LS values obtained by RV analysis also differed significantly among groups. The FW-GLS values only showed significant difference between the control group and moderate MS group (Table 1). Conclusion Patients with mitral stenosis showed lower LV-GLS and higher LV torsion values. Although the LV GLS is affected; the LV EF was detected to be normal due to increase in LV torsion. RV deformation indices showed signıficant decrease in correlation with the severity of the mitral stenosis. In conclusion, our data suggest that subclinical LV and RV systolic dysfunction is present in mild-moderate MS patients and this dysfunction can be detected by 3D-STE. Table 1 Parameters Control group Mild MS Moderate MS P LV GLS (%) 23.3 ± 2.08 18.9 ± 1.3 17.5 ± 1.8 &lt;0.001 LV torsion 1.5 ± 0.6 2.1 ± 0.6 2.6 ± 0.5 &lt;0.001 IVS LS (%) 23 ± 3.0% 20 ± 2.6 17.1 ± 2.9 &lt;0.001 RV FW LS (%) 25.4 ± 5 22.7 ± 3.2 21.1 ± 4.8 &lt;0.001 FW; free-wall, GLS; global longitudinal strain, IVS; interventricular septum, LV; left ventricular, RV; right ventricular Abstract 1187 Figure 1


Perfusion ◽  
2020 ◽  
pp. 026765912092492
Author(s):  
Shehab Anwer ◽  
Didem Oğuz ◽  
Laura Galian-Gay ◽  
Irena Peovska Mitevska ◽  
Lilit Baghdassarian ◽  
...  

Background: The aim of this aortic stenosis registry was to investigate the changes of routine echocardiographic indices and strain in patients with moderate-to-severe aortic stenosis over a 6-month follow-up period. Methods: Our aortic stenosis registry is observational, prospective, multicenter registry of nine countries, with 197 patients with aortic valve area less than 1.5 cm2. The enrolment took place from January to August 2017. We excluded patients with uncontrolled atrial arrhythmias, pulmonary hypertension or cardiomyopathies, as well as those with hemodynamically significant valvular disease other than aortic stenosis. We included patients who did not require intervention and who had a complete follow-up study. Results: In patients with preserved ejection fraction, left ventricular mass has significantly increased between baseline and follow-up studies (218 ± 34 grams vs 253 ± 29 grams, p = 0.02). However, when indexed to body surface area, there was no significant difference. Left ventricular global longitudinal strain significantly decreased (-19.7 ± -4.8 vs (-16.4 vs -3.8, p = 0.01). Left atrial volume was significantly higher at follow-up (p = 0.035). Right ventricular basal diameter and mid-cavity diameter were greater at the follow-up (p = 0.04 and p = 0.035, respectively). Patients with low-flow low-gradient aortic stenosis had significantly lower global longitudinal strain (-12.3% ± -3.9% vs -19.7% ± -4.8%, p = 0.01). Conclusion: Left atrial dilatation is one of the first changes to take place in low-flow low-gradient aortic stenosis patients even when left ventricular dimensions and function remains intact. Global longitudinal strain is an important determinant of left ventricular systolic and diastolic dysfunction and right ventricular function is an important parameter of aortic stenosis assessment. Accordingly, our registry has further shed the light on these indices role as multisite follow-up of aortic stenosis.


2016 ◽  
Vol 19 (3) ◽  
pp. 145 ◽  
Author(s):  
Young Hwa Kong ◽  
Jinyoung Song ◽  
Kyung Hee Kim ◽  
June Huh ◽  
I-Seok Kang

<strong>Background:</strong> Acute changes in left ventricular diastolic function shortly after ASD closure in elderly patients have not been well known. We aimed to investigate acute changes in left ventricular end diastolic pressure (LVEDP) in elderly patients following transcatheter closure of atrial septal defect (ASD). <br /><strong>Methods:</strong> All 19 adults with ASDs who underwent transcatheter closure between June 2013 and December 2014 were enrolled. LVEDP was measured prior to device closure and compared with that immediately following device closure and 15 minutes after device closure. <br /><strong>Results:</strong> The median age of the patients was 48 years old. The baseline E/e’ and LVEDP values were 8.3 ± 2.8 and 13 ± 3 mmHg. The LVEDP value immediately following closure was 19 ± 4 mmHg, and 15 minutes after closure was 16 ± 4 mmHg. The median increase in the LVEDP value immediately following closure was 6 mmHg, which significantly differed from that prior to closure. The LVEDP 15 minutes after closure decreased but remained significantly higher than the value observed immediately after closure. No significant changes were observed with regard to E/e’ at either 1 day or 3 months following closure. The LVEDP value <br />15 minutes after device closure was significantly correlated with those observed before closure and immediately following closure; however, no significant correlations were observed with regard to patient age, Qp/Qs, E/e’ before closure, or E/e’ 3 months after device closure.<br /><strong>Conclusion:</strong> LVEDP in adults with ASDs significantly increases following device closure. LVEDP before closure predicts LVEDP following device closure.


Author(s):  
Akshar Jaglan ◽  
Sarah Roemer ◽  
Ana Cristina Perez Moreno ◽  
Bijoy K Khandheria

Abstract Aims Myocardial work (MW) is a novel parameter that can be used in a clinical setting to assess left ventricular (LV) pressures and deformation. We sought to distinguish patterns of global MW index in hypertensive vs. non-hypertensive patients and to look at differences between categories of hypertension. Methods and results Sixty-five hypertensive patients (mean age 65 ± 13 years; 30 male) and 15 controls (mean age 38 ± 12 years; 7 male) underwent transthoracic echocardiography at rest. Hypertensive patients were subdivided into Stage 1 (n = 32) and Stage 2 (n = 33) hypertension based on 2017 American College of Cardiology guidelines. Exclusion criteria were suboptimal image quality for myocardial deformation analysis, reduced ejection fraction, valvular heart disease, intracardiac shunt, and arrhythmia. Global work index (GWI), global constructive work (GCW), global wasted work (GWW), and global work efficiency were estimated from LV pressure–strain loops utilizing proprietary software from speckle-tracking echocardiography. LV systolic and diastolic pressures were estimated using non-invasive brachial artery cuff pressure. Global longitudinal strain and LV ejection fraction were preserved between the groups with no statistically significant difference, whereas there was a statically significant difference between the control and two hypertension groups in GWI (P = 0.01), GCW (P &lt; 0.001), and GWW (P &lt; 0.001). Conclusion Non-invasive MW analysis allows better understanding of LV response under conditions of increased afterload. MW is an advanced assessment of LV systolic function in hypertension patients, giving a closer look at the relationship between LV pressure and contractility in settings of increased load dependency than LV ejection fraction and global longitudinal strain.


2020 ◽  
Author(s):  
Lori B Croft ◽  
Parasuram Krishnamoorthy ◽  
Richard Ro ◽  
Malcolm Anastasius ◽  
Wenli Zhao ◽  
...  

COVID-19 infection can affect the cardiovascular system. We sought to determine if left ventricular global longitudinal strain (LVGLS) is affected by COVID-19 and if this has prognostic implications. Materials & methods: Retrospective study, with LVGLS was measured in 58 COVID-19 patients. Patients discharged were compared with those who died. Results: The mean LV ejection fraction (LVEF) and LVGLS for the cohort was 52.1 and -12.9 ± 4.0%, respectively. Among 30 patients with preserved LVEF(>50%), LVGLS was -15.7 ± 2.8%, which is lower than the reference mean LVGLS for a normal, healthy population. There was no significant difference in LVGLS or LVEF when comparing patients who survived to discharge or died. Conclusion: LVGLS was reduced in COVID-19 patients, although not significantly lower in those who died compared with survivors.


2011 ◽  
Vol 29 (3) ◽  
pp. 358-362 ◽  
Author(s):  
Mustafa Tarık Ağaç ◽  
Ali Rıza Akyüz ◽  
Zeydin Acar ◽  
Ramazan Akdemir ◽  
Levent Korkmaz ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document