scholarly journals Comment on “The Impact of Treatment with Continuous Positive Airway Pressure on Acute Carbon Monoxide Poisoning”

Author(s):  
David Loughran ◽  
Lewis Nelson
2019 ◽  
Vol 34 (6) ◽  
pp. 588-591 ◽  
Author(s):  
Bahadır Caglar ◽  
Suha Serin ◽  
Gokhan Yilmaz ◽  
Alper Torun ◽  
Ismet Parlak

AbstractIntroduction:Approximately 50,000 patients per year present at emergency departments (EDs) because of carbon monoxide (CO) intoxication. The hypothesis of this study was that the half-life of CO and the regression period of complaints could be reduced more rapidly by applying oxygen with the Continuous Positive Airway Pressure (CPAP) modality using a non-invasive mechanical ventilator.Methods:The patients were divided into Group 1 and Group 2 in terms of the treatment method applied. Patients in Group 1 received FiO2 1.0 15 l/minute oxygen at room temperature for at least 30 minutes with a non-rebreather mask. Patients in Group 2 received FiO2 1.0 oxygen at 12 cmH2O pressure with non-invasive mechanical ventilation for at least 30 minutes with an oronasal mask in the CPAP modality.Results:The median values (interquartile range) of carboxyhemoglobin (COHb) levels at zero and 30 minutes of patients were 19% (8) and 14% (6) in Group 1 and 22% (8) and nine percent (3) in Group 2; a median difference of six percent (2) was detected in Group 1 and of 13% (4) in Group 2 in the first 30 minutes (P <.001). When the symptoms of the patients were examined, the median values of Group 1 and Group 2 at zero minutes were both eight units and at 30 minutes were five and three units, respectively. A decrease of five units was determined in the median of Group 2 in the first 30 minutes, and a decrease of two units in the median of Group 1 (P <.001).Conclusion:The use of CPAP was determined to more rapidly reduce COHb level as opposed to high-flow oxygen therapy. It is also thought that it may enable earlier discharge by reducing the duration of the emergency follow-up since it provides a faster improvement in the symptoms of the patients.


BMJ Open ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. e044499
Author(s):  
Fanny Bertelli ◽  
Carey Meredith Suehs ◽  
Jean Pierre Mallet ◽  
Marie Caroline Rotty ◽  
Jean Louis Pepin ◽  
...  

Introduction To date, continuous positive airway pressure (CPAP) remains the cornerstone of obstructive sleep apnoea treatment. CPAP data describing residual sleep-disordered breathing events (ie, the CPAP-measured apnoea–hypopnoea indices (AHI-CPAPflow)) is difficult to interpret because it is an entirely different metric than the polysomnography (PSG) measured AHI gold standard (AHI-PSGgold). Moreover, manufacturer definitions for apnoea and hypopnoea are not only different from those recommended for PSG scoring, but also different between manufacturers. In the context of CPAP initiation and widespread telemedicine at home to facilitate sleep apnoea care, there is a need for concrete evidence that AHI-CPAPflow can be used as a surrogate for AHI-PSGgold. Methods and analysis No published systematic review and meta-analysis (SRMA) has compared the accuracy of AHI-CPAPflow against AHI-PSGgold and the primary objective of this study is therefore to do so using published data. The secondary objectives are to similarly evaluate other sleep disordered breathing indices and to perform subgroup analyses focusing on the inclusion/exclusion of central apnoea patients, body mass index levels, CPAP device brands, pressure titration modes, use of a predetermined and fixed pressure level or not, and the impact of a 4% PSG desaturation criteria versus 3% PSG on accuracy. The Preferred Reporting Items for SRMA protocols statement guided study design. Randomised controlled trials and observational studies of adult patients (≥18 years old) treated by a CPAP device will be included. The CPAP intervention and PSG comparator must be performed synchronously. PSGs must be scored manually and follow the American Academy of Sleep Medicine guidelines (2007 AASM criteria or more recent). To assess the risk of bias in each study, the Quality Assessment of Diagnostic Accuracy Studies 2 tool will be used. Ethics and dissemination This protocol received ethics committee approval on 16 July 2020 (IRB_MTP_2020_07_2020000404) and results will be disseminated via peer-reviewed publications. PROSPERO/Trial registration numbers CRD42020159914/NCT04526366; Pre-results


2014 ◽  
Vol 40 (6) ◽  
pp. 658-668 ◽  
Author(s):  
Rafaela Garcia Santos de Andrade ◽  
Vivien Schmeling Piccin ◽  
Juliana Araújo Nascimento ◽  
Fernanda Madeiro Leite Viana ◽  
Pedro Rodrigues Genta ◽  
...  

Continuous positive airway pressure (CPAP) is the gold standard for the treatment of obstructive sleep apnea (OSA). Although CPAP was originally applied with a nasal mask, various interfaces are currently available. This study reviews theoretical concepts and questions the premise that all types of interfaces produce similar results. We revised the evidence in the literature about the impact that the type of CPAP interface has on the effectiveness of and adherence to OSA treatment. We searched the PubMed database using the search terms "CPAP", "mask", and "obstructive sleep apnea". Although we identified 91 studies, only 12 described the impact of the type of CPAP interface on treatment effectiveness (n = 6) or adherence (n = 6). Despite conflicting results, we found no consistent evidence that nasal pillows and oral masks alter OSA treatment effectiveness or adherence. In contrast, most studies showed that oronasal masks are less effective and are more often associated with lower adherence and higher CPAP abandonment than are nasal masks. We concluded that oronasal masks can compromise CPAP OSA treatment adherence and effectiveness. Further studies are needed in order to understand the exact mechanisms involved in this effect.


2014 ◽  
Vol 76 ◽  
pp. 100-106
Author(s):  
Francisco Fernández Zacarías ◽  
Ricardo Hernández Molina ◽  
José Luis Cueto Ancela ◽  
Simón Lubián López ◽  
Isabel Benavente Fernández

2010 ◽  
Vol 25 (1) ◽  
pp. 87-91 ◽  
Author(s):  
G. Scott Warner

AbstractObjective:The impact of the use of mask continuous positive airway pressure (CPAP) on patients with acute respiratory distress in the prehospital, rural setting has not been defined. The goal was to test the use of CPAP using the Respironics® WhisperFlow® CPAP in patients presenting with acute respiratory distress. This was a collaborative evaluation of CPAP involving a rural EMS agency and the regional medical center. Patient outcomes including the overall rate of intubation-both in the field and in the emergency department (ED), and length of stay in the hospital and Intensive Care Unit (ICU) were tracked.Methods:The study was an eight-month, crossover, observational, non-blinded study.Results:During the four months of baseline data collection, 7.9% of patients presenting with respiratory distress were intubated within the first 48 hours of care. Their average ICU length of stay was 8.0 days. During the four months of data collection when CPAP was available in the prehospital setting, intubation was not required for any patients in the field or in the ED. Admissions to the ICU decreased. Those patients admitted to the ICU, the average ICU length of stay deceased to 4.3 days.Conclusions:The use of the CPAP in the prehospital setting is beneficial for patients in acute respiratory distress.


2020 ◽  
Vol 26 (7) ◽  
pp. 336-340
Author(s):  
Amy Hough ◽  
Georgia Daisy Dell ◽  
Michael Blaber ◽  
Diana Kavanagh ◽  
Anna Lock

This narrative describes the experiences of an inner city respiratory unit that was transformed to treat COVID-19 patients with continuous positive airway pressure (CPAP) ventilation who were not scheduled for any further escalation in treatment. The high mortality rate and unconventional way of dying led to the creation of local guidance for removing assisted ventilation when the treatment ceased to be effective. We reflect on the specific challenges that caring for these patients holistically has presented and how we have learnt to deliver good palliative care in a unique set of circumstances. We also consider the impact of the pandemic on our team and how the development of a multidisciplinary support system has improved team dynamics and ultimately patient care.


2020 ◽  
Vol 34 (4) ◽  
pp. 487-493 ◽  
Author(s):  
Erin K. Reilly ◽  
Colin T. Huntley ◽  
Maurits S. Boon ◽  
Gregory Epps ◽  
Swar Vimawala ◽  
...  

Background For patients with obstructive sleep apnea (OSA), there is a lack of knowledge regarding the impact of continuous positive airway pressure (CPAP) on the nasal cavity. There is a significant need for evidence-based recommendations regarding the appropriate use of CPAP following endoscopic sinus and skull base surgery. Objective The goal of this study is to translate a previously developed cadaveric model for evaluating CPAP pressures in the sinonasal cavity by showing safety in vivo and quantifying the effect of positive pressurized air flow on the nasal cavity of healthy individuals where physiologic effects are at play. Methods A previously validated cadaveric model using intracranial sensor catheters has proved to be a reliable technique for measuring sinonasal pressures. These sensors were placed in the nasal cavity of 18 healthy individuals. Pressure within the nose was recorded at increasing levels of CPAP. Results Overall, nasal cavity pressure was on average 85% of delivered CPAP. The amount of pressure delivered to the nasal cavity increased as the CPAP increased. The percentage of CPAP delivered was 77% for 5 cmH2O and increased to 89% at 20 cmH2O. There was a significant difference in mean intranasal pressures between all the levels of CPAP except 5 cmH2O and 8 cmH2O ( P < .001). Conclusion On average, only 85% of the pressure delivered by CPAP is transmitted to the nasal cavity. Higher CPAP pressures delivered a greater percentage of pressurized air to the nasal cavity floor. Our results are comparable to the cadaver model, which demonstrated similar pressure delivery even in the absence of anatomic factors such as lung compliance, nasal secretions, and edema. This study demonstrates the safety of using sensors in the human nasal cavity. This technology can also be utilized to evaluate the resiliency of various repair techniques for endoscopic skull base surgery with CPAP administration.