Evaluation of the Effect of Prehospital Application of Continuous Positive Airway Pressure Therapy in Acute Respiratory Distress

2010 ◽  
Vol 25 (1) ◽  
pp. 87-91 ◽  
Author(s):  
G. Scott Warner

AbstractObjective:The impact of the use of mask continuous positive airway pressure (CPAP) on patients with acute respiratory distress in the prehospital, rural setting has not been defined. The goal was to test the use of CPAP using the Respironics® WhisperFlow® CPAP in patients presenting with acute respiratory distress. This was a collaborative evaluation of CPAP involving a rural EMS agency and the regional medical center. Patient outcomes including the overall rate of intubation-both in the field and in the emergency department (ED), and length of stay in the hospital and Intensive Care Unit (ICU) were tracked.Methods:The study was an eight-month, crossover, observational, non-blinded study.Results:During the four months of baseline data collection, 7.9% of patients presenting with respiratory distress were intubated within the first 48 hours of care. Their average ICU length of stay was 8.0 days. During the four months of data collection when CPAP was available in the prehospital setting, intubation was not required for any patients in the field or in the ED. Admissions to the ICU decreased. Those patients admitted to the ICU, the average ICU length of stay deceased to 4.3 days.Conclusions:The use of the CPAP in the prehospital setting is beneficial for patients in acute respiratory distress.

BMJ Open ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. e044499
Author(s):  
Fanny Bertelli ◽  
Carey Meredith Suehs ◽  
Jean Pierre Mallet ◽  
Marie Caroline Rotty ◽  
Jean Louis Pepin ◽  
...  

Introduction To date, continuous positive airway pressure (CPAP) remains the cornerstone of obstructive sleep apnoea treatment. CPAP data describing residual sleep-disordered breathing events (ie, the CPAP-measured apnoea–hypopnoea indices (AHI-CPAPflow)) is difficult to interpret because it is an entirely different metric than the polysomnography (PSG) measured AHI gold standard (AHI-PSGgold). Moreover, manufacturer definitions for apnoea and hypopnoea are not only different from those recommended for PSG scoring, but also different between manufacturers. In the context of CPAP initiation and widespread telemedicine at home to facilitate sleep apnoea care, there is a need for concrete evidence that AHI-CPAPflow can be used as a surrogate for AHI-PSGgold. Methods and analysis No published systematic review and meta-analysis (SRMA) has compared the accuracy of AHI-CPAPflow against AHI-PSGgold and the primary objective of this study is therefore to do so using published data. The secondary objectives are to similarly evaluate other sleep disordered breathing indices and to perform subgroup analyses focusing on the inclusion/exclusion of central apnoea patients, body mass index levels, CPAP device brands, pressure titration modes, use of a predetermined and fixed pressure level or not, and the impact of a 4% PSG desaturation criteria versus 3% PSG on accuracy. The Preferred Reporting Items for SRMA protocols statement guided study design. Randomised controlled trials and observational studies of adult patients (≥18 years old) treated by a CPAP device will be included. The CPAP intervention and PSG comparator must be performed synchronously. PSGs must be scored manually and follow the American Academy of Sleep Medicine guidelines (2007 AASM criteria or more recent). To assess the risk of bias in each study, the Quality Assessment of Diagnostic Accuracy Studies 2 tool will be used. Ethics and dissemination This protocol received ethics committee approval on 16 July 2020 (IRB_MTP_2020_07_2020000404) and results will be disseminated via peer-reviewed publications. PROSPERO/Trial registration numbers CRD42020159914/NCT04526366; Pre-results


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Arash Malakian ◽  
Mohammad Reza Aramesh ◽  
Mina Agahin ◽  
Masoud Dehdashtian

Abstract Background The most common cause of respiratory failure in premature infants is respiratory distress syndrome. Historically, respiratory distress syndrome has been treated by intratracheal surfactant injection followed by mechanical ventilation. In view of the risk of pulmonary injury associated with mechanical ventilation and subsequent chronic pulmonary lung disease, less invasive treatment modalities have been suggested to reduce pulmonary complications. Methods 148 neonates (with gestational age of 28 to 34 weeks) with respiratory distress syndrome admitted to Imam Khomeini Hospital in Ahwaz in 2018 were enrolled in this clinical trial study. 74 neonates were assigned to duo positive airway pressure (NDUOPAP) group and 74 neonates to nasal continuous positive airway pressure (NCPAP) group. The primary outcome in this study was failure of N-DUOPAP and NCPAP treatments within the first 72 h after birth and secondary outcomes included treatment complications. Results there was not significant difference between DUOPAP (4.1 %) and NCPAP (8.1 %) in treatment failure at the first 72 h of birth (p = 0.494), but non-invasive ventilation time was less in the DUOPAP group (p = 0.004). There were not significant differences in the frequency of patent ductus arteriosus (PDA), pneumothorax, intraventricular hemorrhage (IVH) and bronchopulmonary dysplasia (BPD), apnea and mortality between the two groups. Need for repeated doses of surfactant (p = 0.042) in the NDUOPAP group was significantly lower than that of the NCPAP group. The duration of oxygen therapy in the NDUOPAP group was significantly lower than that of the NCPAP group (p = 0.034). Also, the duration of hospitalization in the NDUOPAP group was shorter than that of the NCPAP group (p = 0.002). Conclusions In the present study, DUOPAP compared to NCPAP did not reduce the need for mechanical ventilation during the first 72 h of birth, but the duration of non-invasive ventilation and oxygen demand, the need for multiple doses of surfactant and length of stay in the DUOPAP group were less than those in the CPAP group. Trial registration IRCT20180821040847N1, Approved on 2018-09-10.


2018 ◽  
Vol 37 (1) ◽  
pp. 24-32
Author(s):  
Jennifer M. Guay ◽  
Dru Carvi ◽  
Deborah A. Raines ◽  
Wendy A. Luce

Respiratory distress continues to be a major cause of neonatal morbidity. Current neonatal practice recommends the use of nasal continuous positive airway pressure (nCPAP) in the immediate resuscitation and continued support of neonates of all gestations with clinical manifestations of respiratory distress. Despite the many short- and long-term benefits of nCPAP, many neonatal care units have met resistance in its routine use. Although there have been numerous recent publications investigating the use and outcomes of various modes of nCPAP delivery, surfactant administration, mechanical ventilation, and other forms of noninvasive respiratory support (high-flow nasal cannula, nasal intermittent positive pressure ventilation), there has been a relative lack of publications addressing the practical bedside care of infants managed on nCPAP. Effective use of nCPAP requires a coordinated interprofessional team approach, ongoing assessment of the neonate, troubleshooting the nCPAP circuit, and parent education.


2014 ◽  
Vol 40 (6) ◽  
pp. 658-668 ◽  
Author(s):  
Rafaela Garcia Santos de Andrade ◽  
Vivien Schmeling Piccin ◽  
Juliana Araújo Nascimento ◽  
Fernanda Madeiro Leite Viana ◽  
Pedro Rodrigues Genta ◽  
...  

Continuous positive airway pressure (CPAP) is the gold standard for the treatment of obstructive sleep apnea (OSA). Although CPAP was originally applied with a nasal mask, various interfaces are currently available. This study reviews theoretical concepts and questions the premise that all types of interfaces produce similar results. We revised the evidence in the literature about the impact that the type of CPAP interface has on the effectiveness of and adherence to OSA treatment. We searched the PubMed database using the search terms "CPAP", "mask", and "obstructive sleep apnea". Although we identified 91 studies, only 12 described the impact of the type of CPAP interface on treatment effectiveness (n = 6) or adherence (n = 6). Despite conflicting results, we found no consistent evidence that nasal pillows and oral masks alter OSA treatment effectiveness or adherence. In contrast, most studies showed that oronasal masks are less effective and are more often associated with lower adherence and higher CPAP abandonment than are nasal masks. We concluded that oronasal masks can compromise CPAP OSA treatment adherence and effectiveness. Further studies are needed in order to understand the exact mechanisms involved in this effect.


2014 ◽  
Vol 76 ◽  
pp. 100-106
Author(s):  
Francisco Fernández Zacarías ◽  
Ricardo Hernández Molina ◽  
José Luis Cueto Ancela ◽  
Simón Lubián López ◽  
Isabel Benavente Fernández